TITLE

Spectroscopy and implosion dynamics of low wire number nested arrays on the 1 MA COBRA generator

AUTHOR(S)
Safronova, A. S.; Kantsyrev, V. L.; Esaulov, A. A.; Ouart, N. D.; Yilmaz, M. F.; Williamson, K. M.; Shrestha, I.; Osborne, G. C.; Greenly, J. B.; Chandler, K. M.; McBride, R. D.; Chalenski, D. A.; Hammer, D. A.; Kusse, B. R.; LePell, P. D.
PUB. DATE
March 2008
SOURCE
Physics of Plasmas;Mar2008, Vol. 15 Issue 3, p033302
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Low wire number nested array Z-pinch experiments have been carried out with wires made of aluminum, stainless steel (uniform), and combinations of these two materials (mixed) on the 1 MA COBRA generator at Cornell University [J. D. Douglass, J. B. Greenly, D. A. Hammer et al., in Proceedings of the 15th IEEE International Pulsed Power Conference (IEEE, Piscataway, NJ, 2005)]. The outer array consisted of eight wires, whereas the inner array had four or eight wires. The 10 μm Al wires were alloy 5056 and the 6.25 μm stainless steel wires were alloy SS304. The diagnostic suite included fast-x-ray and extreme ultraviolet (EUV) detectors, a time-gated x-ray pinhole camera, x-ray spectrometers, and laser shadow imaging. The main focus was made on the spectroscopic study of plasma evolution after the main x-ray burst though the data from photoconducting detector (PCD) and EUV signals over the whole period of current, and in addition laser shadowgraphy images before the main x-ray burst were analyzed. Modeling of the time-gated spectra recorded after the main x-ray burst indicates that the electron temperature Te either follows the PCD signals and peaks at times of the second (and the third if present) x-ray burst or has the higher value at the first frame (closest to the main x-ray burst), then slightly changes and increases at the last frame, which coincides with the second maximum of the current. It was also found that the values of Te never drop below 150 eV, and the EUV signal remains intense even when the PCD signal is almost zero.
ACCESSION #
31520925

 

Related Articles

  • The Strength of AISI 304L Rolled Sheet Steel with Thickness up to 25 mm. Stepanov, G. // Chemical & Petroleum Engineering;May/Jun2005, Vol. 41 Issue 5/6, p287 

    An analysis is presented of the documentation on AISI 304L sheet rolled steel, together with the certificates of the manufacturers and the results from input tests on the mechanical properties of this steel. The yield point and ultimate strength of AISI 304L steel of thickness up to 25 mm are...

  • Effect of Double-Stage Aging on the Properties of Maraging Steel 06Kh14N6D2MBT for Force-Measuring Elastic Elements. Tarasenko, L. V.; Krasov, T. A.; Unchikova, M. V. // Metal Science & Heat Treatment;Sep/Oct2004, Vol. 46 Issue 9/10, p411 

    The structure and mechanical properties of maraging corrosion-resistant steel 06Kh14N6D2MBT are studied in different kinds of test after single- and double-stage aging in the presence or absence of retained and reverted austenite. Optimum modes of double-stage aging are determined for improving...

  • Investigation of corrosion behaviors in chloride solutions of G-X 10CrNiMoNb 18-10 austenitic stainless steel produced by different casting techniques. Zor, Sibel; Zeren, Muzaffer; Çapan, Levon; Türker, Mehmet // Protection of Metals & Physical Chemistry of Surfaces;Mar2012, Vol. 48 Issue 2, p270 

    In this study, corrosion resistance of G-X 10CrNiMoNb 18-10 austenitic stainless steel parts, which had been produced through sand molded casting and centrifugal casting methods, and exposed to two-step heat treatments and cooled in different mediums (water, oil, air and oven), in 3.5% NaCl...

  • Observing Effects of Particle Size for a Slurry Using Ultrasonic Diffraction Grating Spectroscopy. Greenwood, M. S.; Brodsky, A.; Burgess, L.; Hamad, M.; Bond, L. J. // AIP Conference Proceedings;2005, Vol. 760 Issue 1, p1729 

    The ultrasonic diffraction grating is formed by machining triangular grooves, 240 microns apart, on the flat surface of a stainless steel (SS) half-cylinder. Ultrasound from a send transducer travels through the SS and strikes the back of the grating where it is reflected to a receive...

  • Wear resistance of nickel–titanium endodontic files after surface treatment. Alves-Claro, A.; Claro, F.; Uzumaki, E. // Journal of Materials Science: Materials in Medicine;Oct2008, Vol. 19 Issue 10, p3273 

    Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on...

  • Pd-Co Dental Casting Ferromagnetic Alloys. KINOUCHI, YOHSUKE; USHITA, TOMIYUKI; TSUTSUI, HIDEO; YOSHIDA, YUKIKO; SASAKI, HIDEKI; MIYAZAKI, TAKESHI // Journal of Dental Research;Jan1981, Vol. 60 Issue 1, p50 

    Three kinds of Pd-Co alloys have been newly developed. Their magnetic and physical properties and corrosion resistances have been examined. As a result, it was found that they are available as the dental casting ferromagnetic alloy which can be used in combination with Sm-Co magnets, over-...

  • Effective technologies and machines for obtaining cold-worked tubes and other products. Sokolovskii, V. I. // Metallurgist;Sep2008, Vol. 52 Issue 9/10, p501 

    This article discusses promising methods and machines developed by Ural State Technical University for the cold rolling of tubes made of medium-carbon and corrosion-resistant steels and titanium and zirconium alloys.

  • Regularities of the deposition of cobalt-tungsten alloys by pulsed currents. Shtefan, V. V.; Ved', M. V.; Sakhnenko, M. D.; Pomoshnyk, L. V.; Fomina, L. P. // Materials Science;May2007, Vol. 43 Issue 3, p429 

    We study the influence of the principal parameters of pulsed electrolysis (amplitude of the current density, frequency and on-off time ratio of the pulses, and the durations of the pulse and pause) on the deposition of cobalt-tungsten alloys. The extreme character of the dependences of current...

  • Effects of modifying trace components on petroleum pipeline corrosion resistance. Makarenko, V.; Makarenko, I.; Ob�edkova, V.; Mukhin, M.; Galichenko, E. // Chemical & Petroleum Engineering;Jul2006, Vol. 42 Issue 7/8, p465 

    A study has been made on the effects of modifying additives on the corrosion resistance of low-alloy steel: rare-earth, alkaline-earth, and zirconium additives. Optimal concentrations have been determined for cerium, yttrium, calcium, barium, and zirconium in steel that provide good corrosion...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics