TITLE

Chromosomal Aberrations in the Peripheral Blood of Patients with Metal-on-Metal Hip Bearings

AUTHOR(S)
Dunstan, E.; Ladon, D.; Whittingham-Jones, P.; Carrington, R.; Briggs, T. W. R.
PUB. DATE
March 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Mar2008, Vol. 90-A Issue 3, p517
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Approximately one-third of patients undergoing joint replacement are under sixty years of age. Many of these patients may be exposed to wear debris from the orthopaedic implant for several decades. Clinical follow-up of this group of patients has been short compared with the lifetimes of the patients, and the long-term effects of this chronic exposure are unknown. Methods: By using cytogenetic biomarkers (twenty-four-color fluorescent in situ hybridization [FISH]), we analyzed the peripheral blood leukocytes for chromosomal aberrations in three groups of subjects: (1) six age and sex-matched control subjects who had no implant and did not smoke (control group), (2) five subjects in whom an implant with a metal-on-metal articulation had been in situ for an average of thirty-five years (metal-on-metal group), and (3) four subjects in whom a metal-on-metal implant had been revised to a metal-on-polyethylene articulation at an average of twenty-two years (revised group). Results: The number of chromosomal aberrations in the metal-on-metal group was greater than that in the control group. Specifically, the percentage of aneuploidy gain was three times greater (p = 0.01) in the metal-on-metal group. Structural aberrations were not seen in the control group, and this difference was highly significant (p = 0.003). Also, the number of chromosomal aberrations in the metal-on-metal group was greater than that in the revised group. Specifically, the percentage of structural aberrations was thirty-one-fold higher (p = 0.013). The percentage of aneuploidy gain in the metal-on-metal group was about twice that in the revised group, although this difference was not significant (p = 0.37). The percentage of aneuploidy gain in the revised group was about double that in the control group, although this difference was also not significant (p = 0.41). Translocations were seen only in subjects with a metal-on-metal articulation.
ACCESSION #
31375450

 

Related Articles

  • Posteromedial compartment cement extrusion after unicompartmental knee arthroplasty treated by arthroscopy: a case report. Weon Yoo Kim; Shafi, Mohamed; Young Yul Kim; Jin Young Kim; Yun Kyoung Cho; Chang Whan Han // Knee Surgery, Sports Traumatology, Arthroscopy;Jan2006, Vol. 14 Issue 1, p46 

    Unicompartmental knee arthroplasty (UKA) with extrusion of cement into the posterior compartment of the knee is uncommon. Various problems after a UKA procedure, such as aseptic loosening, polyethylene wear and progressive arthritis have been reported. This study will report on a patient with...

  • Reconstruction of massive rotator cuff lesions with a synthetic interposition graft: a prospective study of 41 patients. Audenaert, E.; VanNuffel, J.; Schepens, A.; Verhelst, M.; Verdonk, R. // Knee Surgery, Sports Traumatology, Arthroscopy;Apr2006, Vol. 14 Issue 4, p360 

    In the present prospective study, we report about our experience with massive rotator cuff tears treated by means of a nonresorbable transosseously fixated patch combined with subacromial decompression. Forty-one patients were followed clinically and radiographically for a mean duration of 43...

  • Complications and Failure After Total Ankle Arthroplasty. Spirt, Adrienne A.; Assal, Mathieu; Hansen Jr., Sigvard T. // Journal of Bone & Joint Surgery, American Volume;Jun2004, Vol. 86-A Issue 6, p1172 

    Second-generation total ankle arthroplasty has been reported to have good intermediate-term results. The purpose of the present study was to report on the cause and frequency of reoperation and failure after total ankle arthroplasty and to determine demographic and clinical predictors of...

  • The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Rosenberger, Ralf; Fink, Christian; Quirbach, Sebastian; Attal, Rene; Tecklenburg, Katja; Hoser, Christian // Knee Surgery, Sports Traumatology, Arthroscopy;Dec2008, Vol. 16 Issue 12, p1133 

    The success of unicompartmental knee arthroplasty (UKA) is highly dependent on the accuracy of the component alignment. Objective of the present study was to evaluate the immediate effect of image-free computer navigation technology on implant accuracy in primary mini-invasive UKA. This study...

  • The Oxford unicompartmental knee prosthesis: an independent 10-year survival analysis. Vorlat, Peter; Putzeys, Guy; Cottenie, Dominique; Van Isacker, Tom; Pouliart, Nicole; Handelberg, Frank; Casteleyn, Pierre-Paul; Gheysen, Filip; Verdonk, René // Knee Surgery, Sports Traumatology, Arthroscopy;Jan2006, Vol. 14 Issue 1, p40 

    One hundred forty-nine medial prostheses were implanted in 140 patients between 1988 and 1996. After a mean of 67 months 28 patients had died, without the need for revision. Seventeen prostheses were lost to follow-up. Revision surgery using a total knee prosthesis was performed in 16 cases. In...

  • Bone remodelling in humeral arthroplasty: follow-up using CT imaging and finite element modeling – an in vivo case study. Pressel, T.; Lengsfeld, M.; Leppek, R.; Schmitt, J. // Archives of Orthopaedic & Trauma Surgery;May2000, Vol. 120 Issue 5/6, p333 

    Little material is available in the literature about remodelling of the human humerus after implantation of a shoulder hemiarthroplasty. A 73-year-old patient was examined by CT 4 years after implantation of a right shoulder hemiarthroplasty, and the bone density as represented by Hounsfield...

  • Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty. de Beer, Justin; McKenzie, Scott; Hubmann, Matthias; Petruccelli, Danielle; Winemaker, Mitchell // Canadian Journal of Surgery;Dec2006, Vol. 49 Issue 6, p407 

    Introduction: Historically, cemented total hip arthroplasty (THA) femoral stems inserted in varus have yielded poor clinical results. Few studies to date have addressed the question of the effects of varus alignment on cementless stems. We conducted a retrospective review of 125 uncemented THA...

  • Rotationplasty as a salvage procedure in revision of tumor endoprosthesis of the distal femur – a report of two cases. Nebelung, W.; Birger, T.; Röpke, M.; Neumann, H. W. // Archives of Orthopaedic & Trauma Surgery;Sep2000, Vol. 120 Issue 9, p541 

    We performed two rotationplasties (type A1 and A2) as salvage procedures in cases of custom- made endoprosthetic replacements of the distal femur and knee joint. The patients suffered from malignant bone and soft-tissue tumors of the knee, respectively. One of them developed chronic...

  • Uncemented Application of Cemented LCS Knee Prosthesis Leading to Knee Pain. Gaine, William J.; Mohammed, Aslam // Orthopedics;Apr2004, Vol. 27 Issue 4, p417 

    Highlights a previously unreported cause of knee pain after arthroplasty and emphasizes the importance of a surgeon's familiarity with implant components. Information on a case study of a 58-year-old man presented with an LCS knee replacement performed 1 year prior to presentations; Success...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics