Uninstrumented in Situ Fusion for High-Grade Childhood and Adolescent Isthmic Spondylolisthesis: Long-Term Outcome

Helenius, Ilkka; Remes, Ville; Poussa, Mikko
March 2008
Journal of Bone & Joint Surgery, American Volume;Mar2008 Supplement, Vol. 90-A, p145
Academic Journal
BACKGROUND: Intermediate-term radiographic studies have shown that anterior and circumferential techniques result in high fusion rates in patients with high-grade spondylolisthesis, whereas posterolateral fusion is less successful. We are not aware of any long-term comparative studies in which these three methods have been evaluated with regard to functional outcome, including systematic spinal mobility and trunk strength measurements. METHODS: Sixty-nine of eighty-three consecutive patients with high-grade isthmic spondylolisthesis who underwent posterolateral (twenty-one), anterior (twenty-three), or circumferential (twenty-five) uninstrumented spondylodesis between 1977 and 1991 participated in the study. The average duration of follow-up was 17.2 years. Radiographs that were made preoperatively and at the time of the most recent follow-up were assessed with regard to fusion quality and degenerative changes. Outcome was assessed at the time of the most recent follow-up by independent observers on the basis of a physical examination, spinal mobility and nondynamometric trunk strength measurements, and Oswestry Disability Index scores. RESULTS: The mean preoperative vertebral slip was 61% in the posterolateral fusion group, 63% in the anterior fusion group, and 71% in the circumferential fusion group. The final fusion rate was 86% (eighteen of twenty-one) in the posterolateral fusion group, 100% (twenty-three of twenty-three) in the anterior fusion group, and 96% (twenty-four of twenty-five) in the circumferential fusion group. A decrease in lumbar intervertebral disc height at the first mobile level superior to the fusion was noted in five patients in the posterolateral fusion group, seven patients in the anterior fusion group, and one patient in the circumferential fusion group (p = 0.037). The mean Oswestry Disability Index score was 9.7 for the posterolateral fusion group, 8.9 for the anterior fusion group, and 3.0 for the circumferential fusion group.


Related Articles

  • A rare case of spinal injury: bilateral facet dislocation without fracture at the lumbosacral joint. Shinohara, Kei; Soshi, Shigeru; Kida, Yoshikuni; Shinohara, Akira; Marumo, Keishi // Journal of Orthopaedic Science;Mar2012, Vol. 17 Issue 2, p189 

    The article describes the case of an 18-year-old girl who was initially diagnosed with unilateral fractures of the transverse processes of the L2 and L3 vertebrae and anterior spondylolisthesis of the L5 vertebra following a motor vehicle accident. Her symptoms include low back pain and reduced...

  • Staged surgical treatment for severe and rigid scoliosis. Shi Yamin; Li Li; Wei Xing; Gao Tianjun; Zhang Yupeng // Journal of Orthopaedic Surgery & Research;2008, Vol. 3, Special section p1 

    Background: A retrospective study of staged surgery for severe rigid scoliosis. The purpose of this study was to evaluate the result of staged surgery in treatment of severe rigid scoliosis and to discuss the indications. Methods: From 1998 to 2006, 21 cases of severe rigid scoliosis with...

  • An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study. Schumann, Steffen; Liu, Li; Tannast, Moritz; Bergmann, Mathias; Nolte, Lutz-P.; Zheng, Guoyan // Annals of Biomedical Engineering;Oct2013, Vol. 41 Issue 10, p2077 

    The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are...

  • Does Wallis implant reduce adjacent segment degeneration above lumbosacral instrumented fusion? Korovessis, Panagiotis; Repantis, Thomas; Zacharatos, Spyros; Zafiropoulos, Andreas // European Spine Journal;Sep2009, Vol. 18 Issue 6, p830 

    Delayed complications following lumbar spine fusion may occur amongst which is adjacent segment degeneration (ASD). Although interspinous implants have been successfully used in spinal stenosis to authors’ knowledge such implants have not been previously used to reduce ASD in instrumented...

  • Biomechanical evaluation of a new AxiaLIF technique for two-level lumbar fusion. Erkan, Serkan; Chunhui Wu; Mehbod, Amir A.; Hsu, Brian; Pahl, Douglas W.; Transfeldt, Ensor E. // European Spine Journal;Sep2009, Vol. 18 Issue 6, p807 

    Single level axial lumbar interbody fusion (AxiaLIF) using a transsacral rod through a paracoccygeal approach has been developed with promising early clinical results and biomechanical stability. Recently, the transsacral rod has been extended to perform a two-level fusion at both L4–L5...

  • Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model. Kroeze, R. J.; van der Veen, A. J.; van Royen, B. J.; Bank, R. A.; Helder, M. N.; Smit, T. H. // European Spine Journal;Dec2013, Vol. 22 Issue 12, p2731 

    Purpose: To relate the progress of vertebral segmental stability after interbody fusion surgery with radiological assessment of spinal fusion. Methods: Twenty goats received double-level interbody fusion and were followed for a period of 3, 6 and 12 months. After killing, interbody fusion was...

  • Biomechanical assessment of a novel L4/5 level interspinous implant using three dimensional finite element analysis. C. SONG; X.-F. LI; Z.-D. LIU; G.-B. ZHONG // European Review for Medical & Pharmacological Sciences;Jan2014, Vol. 18 Issue 1, p86 

    OBJECTIVES: Range of motion (ROM) is often restricted by conventional spinal fusion surgery, while some complications also occurred after applying posterior dynamic devices in clinic. Therefore, new surgical implant options were necessitated. The biomechanical features of a novel interspinous...

  • Tadpole system as new lumbar spinal instrumentation. Kasai, Yuichi; Inaba, Tadashi; Akeda, Koji; Uchida, Atsumasa // Journal of Orthopaedic Surgery & Research;2008, Vol. 3, Special section p1 

    Background: There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system®. The purposes of this report...

  • The role of prosthesis design on segmental biomechanics. Wilke, Hans-Joachim; Schmidt, René; Richter, Marcus; Schmoelz, Werner; Reichel, Heiko; Cakir, Balkan // European Spine Journal;Jun2012, Vol. 21, p577 

    The purpose of this study was to evaluate the influence of different implant designs of total lumbar disc replacements on the segmental biomechanics of the lumbar spine. The unconstrained Charité, the semi-constrained Prodisc and a semi-constrained Prototype with more posterior centre of...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics