TITLE

Measurements and analysis of bremsstrahlung x-ray spectrum obtained in NANOGAN electron cyclotron resonance ion source

AUTHOR(S)
Baskaran, R.; Selvakumaran, T. S.; Rodrigues, G.; Kanjilal, D.; Roy, A.
PUB. DATE
February 2008
SOURCE
Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02A324
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
From the ECR plasma, hot electrons leak across the magnetic lines of force and by striking the plasma chamber produce bremsstrahlung x-rays. The wall bremsstrahlung gives information on the confinement status of hot electron. In our studies, experimental measurements are carried out in NANOGAN electron cyclotron resonance (ECR) ion source for the wall bremsstrahlung x-rays and the results are presented. While optimizing a particular charge state in ECR ion source, experimental parameters are adjusted to get a maximum current. The wall bremsstrahlung components are studied in these cases for understanding the hot electron confinement conditions.
ACCESSION #
31215836

 

Related Articles

  • Effect of frequency tuning on bremsstrahlung spectra, beam intensity, and shape in the 10 GHz NANOGAN electron cyclotron resonance ion source. Rodrigues, G.; Mal, Kedar; Kumar, Narender; Baskaran, R.; Lakshmy, P. S.; Mathur, Y.; Kumar, P.; Kanjilal, D.; Roy, A. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    Studies on the effect of the frequency tuning on the bremsstrahlung spectra, beam intensities, and beam shape of various ions have been carried out in the 10 GHz NANOGAN ECR ion source. The warm and cold components of the electrons were found to be directly correlated with beam intensity...

  • Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source (abstract only). Leitner, D.; Benitez, J. Y.; Lyneis, C. M.; Todd, D. S.; Ropponen, T.; Ropponen, J.; Koivisto, H.; Gammino, S. // Review of Scientific Instruments;Feb2008, Vol. 79 Issue 2, p02A325 

    High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (versatile ECR for nuclear science), produce large amounts of x rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the...

  • Handling radiation generated during an ion source commissioning. Ren, H. T.; Zhao, J.; Peng, S. X.; Lu, P. N.; Zhou, Q. F.; Xu, Y.; Chen, J.; Zhang, T.; Zhang, A. L.; Guo, Z. Y.; Chen, J. E. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a...

  • A simulation of X-ray shielding for a superconducting electron cyclotron resonance ion source. Jin Yong Park; Mi-Sook Won; Byoung-Seob Lee; Jang-Hee Yoon; Seyong Choi; Jung-Woo Ok; Jeong-SikChoi; Byoung-Chul Kim // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    It is generally assumed that large amounts of x-rays are emitted from the ion source of an Electron Cyclotron Resonance (ECR) instrument. The total amount of x-rays should be strictly limited to avoid the extra heat load to the cryostat of the superconducting ECR ion source, since they are...

  • Influence of ionization cross sections on the gas mixing effect for the production of Ar9+ ions in a CAPRICE ECR source. Delaunay, M. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2861 

    The gas mixing effect in the electron cyclotron resonance (ECR) multicharged ion sources is analyzed while taking into account the ionization cross sections of different support gases such as H[sub 2], He, Ne, N[sub 2], and O[sub 2]. The Ar[sup 9+] ion currents delivered by a CAPRICE ECR ion...

  • The 10-GHz NEOMAFIOS upgraded electron cyclotron resonance ion source. Ludwig, P.; Geller, R.; Melin, G. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2892 

    After the successful development of the first NEOMAFIOS source, an ECRIS for highly charged ions at 8 GHz with a magnetic configuration obtained only with FeNdB permanent magnets, the building of an upgraded NEOMAFIOS at 10 GHz has been achieved. This source started operating a few months ago...

  • A study of the parallel energy distribution of lost electrons from the central plasma of an electron cyclotron resonance ion source. Golovanivsky, K. S.; Melin, G. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2886 

    The electron loss current from the central plasma of a 10 GHz Caprice ion source is analyzed by using a multigrid electrostatic analyzer. It is found that the plasma potential near the axis is negative in the range -10 to -30 V when the rf power varies from 100 to 450 W. It is also shown that...

  • A superconducting electron cyclotron resonance source for the L.N.S. Ciavola, G.; Gammino, S. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2881 

    At the "Laboratorio Nazionale del Sud" (L.N.S.) the K-800 Superconducting Cyclotron (C.S.) is under construction and by the end of 1992 it will be completed in order to work as a booster for the 15-MV Tandem. With this facility fully stripped light ions will reach 100 MeV/amu, while the heaviest...

  • Process of optimization of the ECR CAPRICE sources (abstract). Delaunay, M.; Jacquot, B.; Pontonnier, M. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2860 

    Axial exploration of the plasma in a multicharged electron cyclotron resonance (ECR) CAPRICE ion source was performed with a Langmuir probe and a thermocouple. Hot electron density profile is hollow at the center and the peaks of density are found near the electron cyclotron resonance zones....

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics