TITLE

Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty

AUTHOR(S)
Rosenberger, Ralf; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian
PUB. DATE
March 2008
SOURCE
Knee Surgery, Sports Traumatology, Arthroscopy;Mar2008, Vol. 16 Issue 3, p249
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen™ total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation® Treon plus®, Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the χ2 test. The average postoperative radiological frontal mechanical alignment was 1.88° of varus (range 6.1° of valgus–10.1° of varus; SD 3.68°) in the conventional cohort and 0.28° of varus (range 3.7°–6.0° of varus; SD 1.97°) in the navigated cohort. Including all criteria for optimal implant alignment, 16 cases (32%) in the conventional cohort and 31 cases (62%) in the navigated cohort have been implanted optimally. The average difference in tourniquet time was modest with additional 12.9 min in the navigated cohort compared to the conventional cohort. Our findings suggest that the experienced knee surgeons can improve immediately and constantly the accuracy of component orientation using an image-free computer-assisted navigation system in TKA. The computer-assisted technology has shown to be easy to use, safe, and efficient in routine knee replacement surgery. We believe that navigation is a key technology for various current and future surgical alignment topics and minimal-invasive lower limb surgery.
ACCESSION #
30104709

 

Related Articles

  • The anterior surface of the femur as a new landmark for femoral component rotation in total knee arthroplasty. Talbot, Simon; Bartlett, John // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2008, Vol. 16 Issue 3, p258 

    Femoral component rotation is very important in avoiding complications and maximizing knee function following total knee arthroplasty. There is continuing debate over the most accurate axis to select intraoperatively to obtain the best results. There is considerable doubt over the ability of...

  • Computer-assisted surgery can reduce blood loss after total knee arthroplasty. Hinarejos, Pedro; Corrales, Mónica; Matamalas, Antonia; Bisbe, Elvira; Cáceres, Enric // Knee Surgery, Sports Traumatology, Arthroscopy;May2009, Vol. 17 Issue 4, p356 

    The aim of this study was to compare blood loss and transfusion requirements in patients undergoing computer-assisted total knee arthroplasty (TKA) and patients operated with conventional instrumentation with intra-medullar guides. A prospective randomized study of 87 patients undergoing a TKA...

  • Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Tingart, Markus; Lüring, Christian; Bäthis, Holger; Beckmann, Johannes; Grifka, Joachim; Perlick, Lars // Knee Surgery, Sports Traumatology, Arthroscopy;Jan2008, Vol. 16 Issue 1, p44 

    Restoration of the mechanical leg axis and component positioning are crucial factors affecting long-term results in total knee arthroplasty (TKA). In a prospective study, 1,000 patients were operated on either using a CT-free navigation system or the conventional jig-based technique. Leg...

  • Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Lüring, C.; Oczipka, F.; Perlick, L.; Tingart, M.; Grifka, J.; Bäthis, H. // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2009, Vol. 17 Issue 3, p228 

    Computer assisted (CAS) knee surgery has been established in clinical routine. There is still no study that investigates clinical outcome. Fifty patients who received a primary total knee replacement 2 years before were investigated. These patients were divided into two groups of matched-pairs;...

  • Computer-assisted surgery for total knee arthroplasty: more than just "boy toys" for the passionate few. Point. Hofmann, Aaron A. // Orthopedics;Sep2005, Vol. 28 Issue 9, p940 

    Focuses on the introduction of computer-assisted surgery for total knee arthroplasty in the U.S. in 2001. Different types of computer-assisted systems; Navigation systems that have been developed by manufacturers working in conjunction with orthopedic implant companies; Uses of the universal...

  • Correction of Varus Deformity During TKA With Reduction Osteotomy. Mullaji, Arun; Shetty, Gautam // Clinical Orthopaedics & Related Research;Jan2014, Vol. 472 Issue 1, p126 

    Background: Reduction osteotomy (removing the posteromedial tibial bony flare) is one step to aid in achieving deformity correction in varus arthritic knees during TKA. However, the amount of deformity correction achieved with reduction osteotomy during TKA is unclear. Questions/purposes: We...

  • COMPUTER-ASSISTED SURGERY VERSUS MANUAL TOTAL KNEE ARTHROPLASTY: A CASE-CONTROLLED STUDY. Stulberg, S. David; Yaffe, Mark A.; Koo, Samuel S. // Journal of Bone & Joint Surgery, American Volume;Dec2006 Supplement 4, Vol. 88-A, p47 

    The article presents information on a study that determines the impact of experience with computer-assisted surgery on the manual technique of total knee arthroplasty. In the study, researchers compare the clinical, patient-perceived functional, and radio graphic results of manually performed...

  • Minimally Invasive Navigated Knee Surgery: A European Perspective. Stulberg, S. David // Orthopedics;Oct2005 Supplement, Vol. 28, ps1241 

    Minimally invasive total knee replacement surgery may make it possible for patients to undergo the procedure with less pain and recover from the surgery more quickly than has been previously possible. However, minimally invasive techniques have the potential for being associated with a number of...

  • The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty. da Assunção, R.; Hancock, N.; Bruce, W.; Walker, P. // Knee Surgery, Sports Traumatology, Arthroscopy;Dec2012, Vol. 20 Issue 12, p2528 

    Purpose: Computer-navigated total knee arthroplasty (TKA) improves the accuracy of component implantation. However, the final implant alignment may not match planned alignment. The hypothesis of this study is that although computer navigation improves alignment, imprecision may not be completely...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics