TITLE

The Rationale for Tilt-Adjusted Acetabular Cup Navigation

AUTHOR(S)
Babisch, Jürgen W.; Layher, Frank; Amiot, Louis-Philippe
PUB. DATE
February 2008
SOURCE
Journal of Bone & Joint Surgery, American Volume;Feb2008, Vol. 90-A Issue 2, p357
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: When performing total hip arthroplasty without computer navigation, surgeons align the acetabular component with landmarks such as the plane of the operating table and the presumed position of the pelvis. In contrast, first-generation computer navigation systems rely on the pelvic anterior plane, defined by the anterior superior iliac spines and the pubic tubercle. We sought to study the effect of patient positioning on the tilt of the pelvis as measured in the pelvic anterior plane and its effect on cup alignment angle values. Methods: In forty patients, the supine pelvic anterior plane tilt angle was measured with use of computed tomographic scans made before and after total hip arthroplasty (Group A). In thirty other patients undergoing total hip arthroplasty, preoperative supine pelvic anterior plane tilt angle was measured with a computed tomographic scan and the preoperative standing pelvic anterior plane tilt angle was measured on a lateral radiograph (Group B). From these data, we used hip navigation planning software to develop a nomogram providing tilt-adjusted cup angles that would align the cup in a target range of 40° ± 10° of abduction and 15° ± 10° of anteversion. A third group of ninety-eight patients (Group C) then underwent total hip arthroplasty with computer navigation with use of our nomogram to provide tilt-adjusted values for cup alignment. Postoperative computed tomography scans were made to evaluate cup alignment, and the patients were followed for at least one year. Results: In Group A, the mean preoperative supine pelvic tilt angle (and standard deviation) was -8.9° ± 6.8° (forward rotation of the pelvis) and the mean postoperative angle was -10.9° ± 7.6° (p < 0.05). In Group B, the mean preoperative supine pelvic tilt angle was -10.4° ± 7.4° and the mean preoperative standing pelvic tilt angle was -5.0° ± 9.4° (p < 0.001). In the group of ninety-eight patients who underwent navigated total hip arthroplasty (Group C), there were no dislocations at one year of follow-up. Seventy-two patients underwent postoperative computed tomography scans; 99% of cup anteversion values and 97% of cup abduction values were in the target range. Conclusions: For navigation systems that rely on the pelvic anterior plane, cup alignment values can be converted to familiar target values with our nomogram with good accuracy and reproducibility. The next generation of navigation systems should be able to measure the pelvic tilt for each individual patient and automatically adjust alignment values. Level of Evidence: Diagnostic Level II. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
30000048

 

Related Articles

  • Influence of acetabular rim profile on hip dislocation. Maher, S. A.; Lipman, J. D. // Proceedings of the Institution of Mechanical Engineers -- Part H;Nov2006, Vol. 220 Issue 8, p881 

    Dislocation is the second most common complication in total hip arthroplasty, with reported incidences of up to 8 per cent. The authors' hypothesis is that, by modifying the rim of an acetabular component in order to shift the femoral neck contact position towards the periphery of the...

  • Improving the Accuracy of Acetabular Component Orientation: Avoiding Malpositioning. Moskal, Joseph T.; Capps, Susan G.; Scanelli, John A. // Journal of Bone & Joint Surgery, American Volume;6/5/2013, Vol. 95-A Issue 11, p1044 

    The article focuses on improving the accuracy of acetabular component orientation. The use of larger femoral head sizes in primary total hip arthroplasty has increased in recent years with the introduction of alternative bearings and reduced short-tern dislocation. Many factors can negatively...

  • Total hip arthroplasty: to cement or not to cement the acetabular socket? A critical review of the literature. Clement, N.; Biant, L.; Breusch, S. // Archives of Orthopaedic & Trauma Surgery;Mar2012, Vol. 132 Issue 3, p411 

    The optimal method for acetabular socket fixation remains controversial. We present a critical analysis of the current evidence from a systemic literature review of comparative studies, long-term case series, prior literature reviews, meta-analysis, and national arthroplasty registry data for...

  • Vascularized pedicled iliac crest graft for selected total hip acetabular reconstructions: a cadaver study. G. Karakurum; A. Gülec; O. Büyükbebeci // Surgical & Radiologic Anatomy;Feb2004, Vol. 26 Issue 1, p3 

    Bone grafting is an essential part of most total hip acetabular reconstructions. There are a limited number of surgical options, each with inherent disadvantages for the management of structural acetabular defects. In this cadaver study, the authors aimed to evaluate the availability of...

  • Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips. Bosker, B.; Ettema, H.; Rossum, M.; Boomsma, M.; Kollen, B.; Verheyen, C.; Maas, M. // Archives of Orthopaedic & Trauma Surgery;Mar2015, Vol. 135 Issue 3, p417 

    Introduction: The incidence and natural course of pseudotumors in metal-on-metal total hip arthroplasties is largely unknown. The objective of this study was to identify the true incidence and risk factors of pseudotumor formation in large head metal-on-metal total hip arthroplasties. Materials...

  • Locking versus standard screw fixation for acetabular cups: is there a difference? Heller, Snir; Brosh, Tamar; Kosashvili, Yona; Velkes, Steven; Burg, Alon; Dudkiewicz, Israel // Archives of Orthopaedic & Trauma Surgery;May2013, Vol. 133 Issue 5, p701 

    Introduction: Total hip replacement has been established as a valid treatment option for displaced subcapital fractures. However, insufficient primary fixation may be the reason for early loosening in these osteoporotic patients. Primary fixation of the cup is usually achieved by press-fit...

  • Short-term wear of Japanese highly cross-linked polyethylene in cementless THA. Miyanishi, Keita; Hara, Toshihiko; Kaminomachi, Shigekazu; Maekawa, Masayuki; Iwamoto, Mikio; Torisu, Takehiko // Archives of Orthopaedic & Trauma Surgery;Sep2008, Vol. 128 Issue 9, p995 

    Production of polyethylene wear from acetabular liners is thought, in part, to mediate the periprosthetic osteolysis. This study examined the in vivo wear performance of Japanese highly cross-linked polyethylene (Aeonian) in cementless total hip arthroplasty. Ninety-five hips received a highly...

  • Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement. Ching-Ho Wu; Cheng-Chung Lin; Tung-Wu Lu; Sheng-Mao Hou; Chih-Chung Hu; Lih-Seng Yeh // BioMedical Engineering OnLine;2013, Vol. 12 Issue 1, p2 

    Background Total hip replacement (THR) is considered to be the most effective treatment option for advanced osteoarthritis of the hip in large breed dogs. However, a proportion of post-THR patients suffer prosthesis dislocation for various reasons, which may be addressed by a constrained...

  • Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Sendtner, Ernst; Schuster, Tibor; Wörner, Michael; Kalteis, Thomas; Grifka, Joachim; Renkawitz, Tobias // International Orthopaedics;Jun2011, Vol. 35 Issue 6, p809 

    In a prospective and randomised clinical study, we implanted acetabular cups either by means of an image-free computer-navigation system (navigated group, n = 32) or by free-hand technique (freehand group n = 32, two drop-outs). Total hip replacement was conducted in the lateral position and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics