ABSTRACT
Background: The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods: Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock) with percutaneous fixation pins was employed in the remaining 39. Results: Technical problems related to the fixing of the trackers appeared in nine cases (2.5%). The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2-7), and 5 minutes in the case of the femoral pin (range: 4-11), although with the new tool it was only three minutes (range 2-4) (p < 0.001). No complications were observed with this new device. Conclusion: The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.
ACCESSION #
29438237

 

Related Articles

  • Radiographic features predictive of patellar maltracking during total knee arthroplasty. Shi-Lu Chia; Merican, Azhar M.; Devadasan, Bernard; Strachan, Robin K.; Amis, Andrew A. // Knee Surgery, Sports Traumatology, Arthroscopy;Dec2009, Vol. 17 Issue 10, p1217 

    Despite improvements in component design and surgical technique, some patients still require lateral retinacular release during TKA to improve patella tracking. We studied 148 fixed-bearing TKAs to identify parameters in pre-operative knee radiographs that would predict intraoperative patellar...

  • How much of the PCL is really preserved during the tibial cut? Matziolis, Georg; Mehlhorn, Saskia; Schattat, Nicole; Diederichs, Gerd; Hube, Robert; Perka, Carsten; Matziolis, Doerte // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2012, Vol. 20 Issue 6, p1083 

    Purpose: There are two different techniques for retaining the posterior cruciate ligament (PCL) in total knee arthroplasty. The attachment of the PCL can be spared during resection of the tibial plateau, so that a small posterior bone block remains. In contrast to this, many surgeons resect the...

  • Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee Arthroplasty. Bédard, Martin; Vince, Kelly; Redfern, John; Collen, Stacy // Clinical Orthopaedics & Related Research;Aug2011, Vol. 469 Issue 8, p2346 

    Background: Stiffness complicating TKA is a complex and multifactorial problem. We suspected internally rotated components compromised motion because of pain, patellar maltracking, a tight medial flexion gap, and limited femoral rollback on a conforming lateral tibial condyle....

  • COMPUTER-ASSISTED KNEE ARTHROPLASTY IS BETTER THAN A CONVENTIONAL JIG-BASED TECHNIQUE IN TERMS OF COMPONENT ALIGNMENT. Sk., Chauhan; Rg., Scott; W., Breidahl; Rj., Beaver // Journal of Bone & Joint Surgery, American Volume;Nov2004, Vol. 86-A Issue 11, p2573 

    The article compares the efficacy of computer-assisted knee arthroplasty (CAKA) with a conventional jig-based knee arhroplasty (JBKA) technique in patients having knee arthroplasty. CAKA was done using the Stryker Knee Navigation system which makes use of anatomical mapping of the knee and...

  • Comparison of patellar retention versus resurfacing in LCS mobile-bearing total knee arthroplasty. Hwang, Bo-Hyun; Yang, Ick-Hwan; Han, Chang-Dong // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2012, Vol. 20 Issue 3, p524 

    Purpose: The aim of this retrospective study was to compare clinical outcomes of total knee arthroplasty (TKA) with and without patellar resurfacing using the Low Contact Stress (LCS) mobile-bearing prosthesis in 275 osteoarthritic knees (199 patients) after a minimum of 7 years of follow-up....

  • Lateral Unicompartmental Replacement: A Road Less Traveled. Scott, Richard D. // Orthopedics;Sep2005, Vol. 28 Issue 9, p983 

    Focuses on the decrease in the number of patients undergoing lateral unicompartmental knee arthroplasty (UKA) in the U.S. in 2005. Indications for lateral UKA; Comparison of the surgical technique for lateral UKA and that of medical replacement; Approach that should be taken to avoid imparting...

  • Reduziert ein erhöhter tibialer Slope den Abrieb bei unikondylären Schlittenprothesen? Weber, P.; Schröder, C.; Utzschneider, S.; Schmidutz, F.; Jansson, V.; Müller, P.E. // Der Orthopäde;Apr2012, Vol. 41 Issue 4, p298 

    Introduction: Unicompartmental knee arthroplasty (UKA) has become a standard procedure with good clinical outcome in patients with isolated medial osteoarthritis of the knee. However, the survival rates of UKA are still inferior compared to that of total knee arthroplasty. Aseptic loosening and...

  • Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty. Dong-Hoon Lee; Jai-Gon Seo; Young-Wan Moon // International Orthopaedics;Apr2008, Vol. 32 Issue 2, p223 

    Abstract  The rotational axis of the tibial component in total knee arthroplasty described by Insall is generally accepted, but rotational mismatch between the femoral and the tibial components can occur because the alignment of each component is determined separately. We developed a...

  • Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study. Rossi, Roberto; Bruzzone, Matteo; Bonasia, Davide Edoardo; Marmotti, Antonio; Castoldi, Filippo // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2010, Vol. 18 Issue 7, p889 

    Various techniques exist for establishing tibial rotational alignment during total knee arthroplasty (TKA). The purpose of this study is to establish the most precise and reproducible method to assess tibial component rotational alignment during TKA by comparing the flexion-extension technique...