TITLE

Prevalence study of Legionella spp. contamination in ferries and cruise ships

AUTHOR(S)
Azara, Antonio; Piana, Andrea; Sotgiu, Giovanni; Dettori, Marco; Deriu, Maria Grazia; Masia, Maria Dolores; Are, Bianca Maria; Muresu, Elena
PUB. DATE
January 2006
SOURCE
BMC Public Health;2006, Vol. 6, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: In the last years, international traffic volume has significantly increased, raising the risk for acquisition of infectious diseases. Among travel-associated infections, increased incidence of legionellosis has been reported among travellers. Aim of our study was: to describe the frequency and severity of Legionella spp. contamination in ferries and cruise ships; to compare the levels of contamination with those indicated by the Italian ministerial guidelines for control and prevention of legionellosis, in order to assess health risks and to adopt control measures. Method: A prevalence study was carried out on 9 ships docked at the seaports of northern Sardinia in 2004. Water samples were collected from critical sites: passenger cabins, crew cabins, kitchens, coffee bars, rooms of the central air conditioning system. It was performed a qualitative and quantitative identification of Legionella spp. and a chemical, physical and bacteriological analysis of water samples. Results: Forty-two percent (38/90) water samples were contaminated by Legionella spp.. Positive samples were mainly drawn from showers (24/44), washbasins (10/22). L. pneumophila was isolated in 42/44 samples (95.5%), followed by L. micdadei (4.5%). Strains were identified as L. pneumophila serogroup 6 (45.2%; 19 samples), 2-14 (42.9%), 5 (7.1%) and 3 (4.8%). Legionella spp. load was high; 77.8% of the water samples contained > 104 CFU/L. Low residual free chlorine concentration (0-0,2 mg/L) was associated to a contamination of the 50% of the water samples. Conclusion: Legionella is an ubiquitous bacterium that could create problems for public health. We identified Legionella spp. in 6/7 ferries. Microbial load was predominantly high (> 104 CFU/L or ranging from 10³ to 104 CFU/L). It is matter of concern when passengers are subjects at risk because of Legionella spp. is an opportunist that can survive in freshwater systems; high bacterial load might be an important variable related to disease's occurrence. High level of contamination required disinfecting measures, but does not lead to a definitive solution to the problem. Therefore, it is important to identify a person responsible for health safety in order to control the risk from exposure and to apply preventive measures, according to European and Italian guidelines
ACCESSION #
29362247

 

Related Articles

  • Prevalence of legionella waterline contamination and Legionella pneumophila antibodies in general dental practitioners in London and rural Northern Ireland. Pankhurst, C. L.; Coulter, W.; Philpott-Howard, J. J.; Harrison, T.; Warburton, F.; Platt, S.; Surman, S.; Challacome, S. // British Dental Journal;11/22/2003, Vol. 195 Issue 10, p591 

    Objectives To determine the prevalence of legionellae in dental unit waterlines (DUWL) in general dental practices in London and rural Northern Ireland and whether the organism occurs at a high enough frequency and magnitude in DUWL to represent a threat to dentists' health.Materials and method...

  • Legionella pneumophila induces cathepsin B-dependent necrotic cell death with releasing high mobility group box1 in macrophages. Morinaga, Yoshitomo; Yanagihara, Katsunori; Nakamura, Shigeki; Hasegawa, Hiroo; Seki, Masafumi; Izumikawa, Koichi; Kakeya, Hiroshi; Yamamoto, Yoshihiro; Yamada, Yasuaki; Kohno, Shigeru; Kamihira, Shimeru // Respiratory Research;2010, Vol. 11, p158 

    Background: Legionella pneumophila (LPN) can cause a lethal infectious disease with a marked inflammatory response in humans. However, the mechanism of this severe inflammation remains poorly understood. Since necrosis is known to induce inflammation, we investigated whether LPN induces necrosis...

  • PCR as a test for the presence or absence of Legionella in (cooling) water. P. Declerck; L. Verelst; L. Duvivier; A. Van Damme; F. Ollevier // Water Science & Technology;Feb2003, Vol. 47 Issue 3, p103 

    Legionella pneumophila, a Gram-negative bacterium, is the causative agent of legionellosis. Traditionally, culture methods are normally used to detect Legionella species in different types of water (e.g. surface or tap water, circulating systems, air conditioners and their cooling devices). In...

  • Legionella contamination of waterlines? Walker, J. // British Dental Journal;11/22/2003, Vol. 195 Issue 10, p581 

    ObjectivesTo determine the prevalence of legionellae in dental unit waterlines (DUWL) in general dental practices in London and rural Northern Ireland and whether the organism occurs at a high enough frequency and magnitude in DUWL to represent a threat to dentists' health.Materials and...

  • Legionella pneumophila in Rainwater on Roads. Sakamoto, Ryota; Ohno, Akira; Nakahara, Toshitaka; Satomura, Kazunari; Iwanaga, Suketaka; Kouyama, Yuuichiro; Kura, Fumiaki; Kato, Naoyuki; Matsubayashi, Kozo; Okumiya, Kiyohito; Yamaguchi, Keizo // Emerging Infectious Diseases;Aug2009, Vol. 15 Issue 8, p1295 

    During rain, transient puddles form on roads, and this water is splashed into the air by moving vehicles. To determine whether this water contains Legionella pneumophila, we collected samples from roads. We found that L. pneumophila are abundant in these puddles, especially during warm weather.

  • Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait. Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad // Environmental Science & Pollution Research;Jul2015, Vol. 22 Issue 13, p10235 

    The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These...

  • Legionella in residential water systems. Stout, Janet E.; Muder, Robert R. // ASHRAE Journal;May2004, Vol. 46 Issue 5, p52 

    Presents an overview of research findings and what can be done to eradicate Legionella in home water systems. Link to home exposure made if the identical strain that infected the patient was also found in the home water system; Occurrence of diseases associated with the microbe in individuals...

  • Detection of Legionella Spp. in Water from Cooling Towers. Baghal Asghari, Farzaneh; Nikaeen, Mahnaz; Hatamzadeh, Maryam; Vahid Dastjerdi, Marzieh; Hassanzadeh, Akbar // Journal of Isfahan Medical School;9/3/2012, Vol. 30 Issue 195, p1 

    Background: Legionella are Gram negative and non-spore bacteria which are found in various natural and manmade aquatic environments. Legionella can cause legionnaires' disease or Pontiac fever. Inhalation of aerosols from contaminated water sources leads to Legionella infections or...

  • The fate of legionellae within distribution pipe biofilms: measurement of their persistence, inactivation and detachment. Storey, M. V.; Långmark, J.; Ashbolt, N. J.; Stenström, T. A. // Water Science & Technology;2004, Vol. 49 Issue 11/12, p269 

    Distribution pipe biofilms present a currently unquantified public health risk to consumers receiving water for domestic potable and non-potable use. The aim of this study was to quantify the numbers of legionellae, used here as model bacterial pathogens, that may accumulate, persist within and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library