TITLE

TASARIM VE UYGULAMASI YAPILAN BİR ULTRASONİK AKIŞ ÖLÇERİN KALİBRASYONU

AUTHOR(S)
İskender, İres; Erta ş, Emre; Genç, Naci
PUB. DATE
December 2007
SOURCE
Journal of the Faculty of Engineering & Architecture of Gazi Uni;Dec2007, Vol. 22 Issue 4, p759
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this paper, the experimental studies of different flow density values have been carried on a designed and implemented flow meter being known as ultrasound working based on high frequency sound wave technology. The calibration of the flow meter has been realized using the results obtained from the study. The transit-time method has been used as the basis of the flow measure. For calibration of the flow meter, the experimental study has been carried on twenty different flow densities and the differences between the measured and the exact values have been observed. Then, to minimize these differences, two different calibration methods being 'linearequation' and 'artificial-neural-network' methods have been developed and the results have been obtained. Using the results, the two mentioned methods have been compared and those effects on the accuracy of the flow meter have been discussed. It has been shown that between these two methods the accuracy of the 'neuralnetwork' method is higher than that of the 'linear-equation' method.
ACCESSION #
28652966

 

Related Articles

  • Neuro-Hybrid Models for Automotive System Identification. Assuncao, Ventura // Enformatika;2006, Vol. 12, p94 

    In automotive systems almost all steps concerning the calibration of several control systems, e.g., low idle governor or boost pressure governor, are made with the vehicle because the time-to-production and cost requirements on the projects do not allow for the vehicle analysis necessary to...

  • Feeling the heat. Cox, Stephen // Processing (08968659);Jul2009 Flowmeter Solutions, p8 

    The article offers tips for air/gas flow measurement in high-temperature environments. It is stated that in selecting a flowmeter for any application, the first step is choosing the appropriate flow technology. It is advised that when looking at any flow technology one should consider factors...

  • The whole truth and nothing but the truth? Franklin, Bryan // Control Solutions;Jan2003, Vol. 76 Issue 1, p37 

    Provides information on the process of testing flowmeters. Advice on ensuring a flowmeter calibration; Tips on flow measurement accuracy during calibration; Recommendations from flow calibration experts.

  • Flowmeter Turndown Overkill. Spitzer, David W. // Flow Control;Feb2010, Vol. 16 Issue 2, p12 

    The article discusses the author's views on the validity of claims from instrument suppliers regarding the performance of flowmeters meeting the needs of their applications. He muses on the facts of flowmeter turndown that has to be supported by test data based on actual operations at certain...

  • Development and performance analysis of a standard orifice flow calibration system. Akram, H. M.; Maqsood, M.; Rashid, H. // Review of Scientific Instruments;Jul2009, Vol. 80 Issue 7, p075103 

    An orifice flow system has been developed indigenously which is a primary standard for the calibration of high vacuum gauges in the range of 10-3–10-6 mbar. It consists of a constant-volume flow meter, designed to generate a known flow rate of a particular gas to the vacuum chamber. This...

  • TO Calibrate or NOT to Calibrate. Keizers, Ben; Shipps, Kyle // Flow Control;Jan2014, Vol. 20 Issue 1, p22 

    The article offers suggestions on calibrating flowmeters. It stated that failure to calibrate flowmeters can have negative impact performance, while frequent calibrating too can result in excessive costs without benefits. It is suggested that performing a plant-wide assessment of all instruments...

  • A research of dynamic compensation of coriolis mass flowmeter based on BP neural networks. Zheng, Dezhi; Peng, Peng; Fan, Shangchun // Instruments & Experimental Techniques;May2013, Vol. 56 Issue 3, p365 

    As a resonate sensor, Coriolis Mass Flowmeter (CMF) provides a direct measurement of mass flow and is widely used in flow measurement field. However, defect of dynamic characteristics has become the main factor which restricts its further application in batch filling processes. Based on...

  • quiz corner: Which Flowmeters Measure Mass? Spitzer, David W. // Flow Control;May2014, Vol. 20 Issue 5, p48 

    A quiz concerning the types of flowmeters that measure mass, including turbine, oscillating piston, and orifice plate, is presented.

  • By-the-weigh flow calibration. Cheatle, Keith // InTech;May2006, Vol. 53 Issue 5, p68 

    The article presents information on flow calibration. This system is necessary for any transducers that provide information on the amount of material transferred in a given time. The measurements occur in units of mass per unit time of volume per unit time. These measurements relate to one...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics