TITLE

Validation of the NITI Endoluminal Compression Anastomosis Ring (EndoCAR) Device and Comparison to the Traditional Circular Stapled Colorectal Anastomosis in a Porcine Model

PUB. DATE
December 2007
SOURCE
Surgical Innovation;Dec2007, Vol. 14 Issue 4, p252
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
No abstract available.
ACCESSION #
28324182

 

Related Articles

  • Comparison of the Compression Anastomosis Ring (EndoCAR) With a Circular Stapled Anastomosis in a Porcine Model. Chun, Jonathan; Lee, Dooseok; Stewart, David; Talcott, Michael; Fleshman, James // Surgical Innovation;Sep2011, Vol. 18 Issue 3, p235 

    Purpose. The aim of this study was to compare characteristics of rectal compression and stapled anastomoses at multiple time points. Methods. A total of 50 domestic pigs underwent a rectal anastomosis with a compression device or a circular stapler. They were sacrificed at zero-time, 2 days, 1...

  • Compression anastomoses in colorectal surgery: a review. Zbar, A.; Nir, Y.; Weizman, A.; Rabau, M.; Senagore, A. // Techniques in Coloproctology;Jun2012, Vol. 16 Issue 3, p187 

    The main serious risks of anastomotic construction in the colon and rectum include dehiscence and stricture formation. There is a resurgence of interest in sutureless anastomoses formed by compression elements since the introduction of shape memory alloy (SMA) systems, which evoke minimal early...

  • Safety of the NiTi EndoCAR Following Chemoradiation in a Porcine Model. Chun, Jonathan; Parikh, Parag; Lee, Dooseok; Fleshman, James // Surgical Innovation;Dec2011, Vol. 18 Issue 4, p394 

    Purpose. To assess the safety of anastomosis ring (EndoCAR) following chemoradiation. Methods. A total of 10 pigs received radiation to a bioequivalent dose of 4500 cGy with 4 doses of 5-fluorouracil 400 mg/m2 and leucovorin 20 mg/m2 intravenous bolus. On day 21, each animal underwent 2 rectal...

  • The effect of tissue compression on circular stapler line failure. Myers, Stephan R.; Rothermel, Jr., William S.; Shaffer, Lynn // Surgical Endoscopy;Sep2011, Vol. 25 Issue 9, p3043 

    Background: Anastomotic leak after gastrointestinal anastomosis is a well-known and serious complication, yet there is no standardized approach to reliably create an anastomosis with sufficient mechanical properties to consistently avoid an anastomotic leak. The purpose of this study was to...

  • NiTi wins patent for ColonRing; Atherotech gets patent for VAP.  // Medical Device Daily;5/20/2009, Vol. 13 Issue 96, p6 

    The article reports on NiTi Surgical Solutions' acquisition of a patent from the U.S. Patent and Trademark Office (USPTO), which covered compression anastomosis ring assembly for joining severed organ wall portions of a hollow organ. Patent No. 7,527,185 would include the company's ColonRing...

  • Early Surgical Outcomes of NiTi Endoluminal Compression Anastomotic Clip (NiTi CAC 30) Use in Patients with Gastrointestinal Malignancy. Kim, Hyoung Ran; Lee, Woo Yong; Jung, Kyung Uk; Yun, Hae-Ran; Cho, Yong Beom; Yun, Seong Hyeon; Kim, Hee Cheol; Chun, Ho-Kyung // Journal of Laparoendoscopic & Advanced Surgical Techniques;Jul/Aug2012, Vol. 22 Issue 6, p472 

    Background: The NiTi endoluminal Compression Anastomotic Clip (CACâ„¢) 30 (NiTi CAC 30) (NiTi Alloys Technologies, Ltd., Netanya, Israel) is a new device with shape-memory characteristics. We aimed to investigate the safety and early surgical outcomes of NiTi CAC 30 for intestinal...

  • Evaluation of the NiTi Shape Memory BioDynamix ColonRingâ„¢ in colorectal anastomosis: first in human multi-center study. Tulchinsky, Hagit; Kashtan, Hanoch; Rabau, Micha; Wasserberg, Nir // International Journal of Colorectal Disease;Dec2010, Vol. 25 Issue 12, p1453 

    Background : Shape-memory compression bowel anastomosis using a nickel and titanium alloy may reduce leak rates and eliminate foreign anastomotic material. Its safety and efficacy had been demonstrated by animal studies. We conducted the first prospective multi-center clinical evaluation of the...

  • ColonRing used in Chinese colorectal surgery.  // Medical Device Daily;12/22/2009, Vol. 13 Issue 245, p7 

    The article reports that the ColonRing anastomosis device of NiTi Surgical Solutions has been used for the first time in a colorectal surgery in China. The sigmoidectomy was performed by professor Cai at The Fudan University Shanghai Cancer Hospital. The professor asserted that the device...

  • Anastomosis colorrectales por compresión utilizando el dispositivo NiTi. González-Contreras, Quintín Héctor; de Jesús-Mosso, Mónica; Bahena-Aponte, Jesús Alberto; Aldana-Martínez, Omar; Pineda-Solís, Karen; Mejia-Arcadia, Sari Narsil // Cirugia y Cirujanos;nov/dic2016, Vol. 84 Issue 6, p482 

    Background: The most severe complication following an intestinal anastomosis is the dehiscence with the consequent development of sepsis, fistulas, stenosis, and death. For this reason the compression anastomosis (NiTi) system was developed, with the aim of reducing these complications. Material...

  • Safety and Efficacy of the NiTi Shape Memory Compression Anastomosis Ring (CAR/ColonRing) for End-to-End Compression Anastomosis in Anterior Resection or Low Anterior Resection. Kang, Jeonghyun; Park, Min Geun; Hur, Hyuk; Min, Byung Soh; Lee, Kang Young; Kim, Nam Kyu // Surgical Innovation;Apr2013, Vol. 20 Issue 2, p164 

    Purpose. Compression anastomoses may represent an improvement over traditional hand-sewn or stapled techniques. This prospective exploratory study aimed to assess the efficacy and complication rates in patients undergoing anterior resection (AR) or low anterior resection (LAR) anastomosed with a...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics