TITLE

Comparative performance study of different sample introduction techniques for rapid and precise selenium isotope ratio determination using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS)

AUTHOR(S)
Elwaer, Nagmeddin; Hintelmann, Holger
PUB. DATE
November 2007
SOURCE
Analytical & Bioanalytical Chemistry;Nov2007, Vol. 389 Issue 6, p1889
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The analytical performance of five sample introduction systems, a cross flow nebulizer spray chamber, two different solvent desolvation systems, a multi-mode sample introduction system (MSIS), and a hydride generation (LI2) system were compared for the determination of Se isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). The optimal operating parameters for obtaining the highest Se signal-to-noise (S/N) ratios and isotope ratio precision for each sample introduction were determined. The hydride generation (LI2) system was identified as the most suitable sample introduction method yielding maximum sensitivity and precision for Se isotope ratio measurement. It provided five times higher S/N ratios for all Se isotopes compared to the MSIS, 20 times the S/N ratios of both desolvation units, and 100 times the S/N ratios produced by the conventional spray chamber sample introduction method. The internal precision achieved for the 78Se/82Se ratio at 100 ng mL−1 Se with the spray chamber, two desolvation, MSIS, and the LI2 systems coupled to MC-ICP/MS was 150, 125, 114, 13, and 7 ppm, respectively. Instrument mass bias factors (K) were calculated using an exponential law correction function. Among the five studied sample introduction systems the LI2 showed the lowest mass bias of −0.0265 and the desolvation system showed the largest bias with −0.0321. [Figure not available: see fulltext.]
ACCESSION #
27734017

 

Related Articles

  • Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry. Maldonado, Domingo; Chirinos, José; Benzo, Zully; Marcano, Eunice; Gómez, Clara; Salas, Janeth; Quintal, Manuelita; D'Suze, Gina // Microchimica Acta;Jul2008, Vol. 162 Issue 1/2, p93 

    The analytical performance of a low cost direct injection high efficiency nebulizer (DIHEN) with replaceable capillary is evaluated and compared with a high efficiency nebulizer HEN-cyclonic spray chamber arrangement for sample introduction at lower solution uptake rates in inductively coupled...

  • Focus on sample handling. Nerín, Cristina // Analytical & Bioanalytical Chemistry;Jul2007, Vol. 388 Issue 5/6, p1001 

    The author comments on the series of Symposia organized by the International Association of Environmental and Analytical Chemistry that addressed the role of sample handling in analytical and bioanalytical chemistry. The highlights of the final symposium that took place in Zaragoza, Spain, in...

  • Rapid Determination of the Chemical Oxygen Demand in Water with the Use of High-Temperature Solid-Electrolyte Cells. Zuev, B. K.; Korotkov, A. A.; Filonenko, V. G.; Mashkovtsev, A. N.; Zvolinskii, V. P. // Journal of Analytical Chemistry;Feb2004, Vol. 59 Issue 2, p163 

    A new procedure is proposed for the determination of the oxidazibility of organic and inorganic matter in water (an analogue of the chemical oxygen demand (COD)). The procedure is based on high-temperature oxidation in a controlled binary oxygen–inert gas mixture and the determination of...

  • Sample preparation for speciation. Cámara, Carmen // Analytical & Bioanalytical Chemistry;Jan2005, Vol. 381 Issue 2, p277 

    Focuses on the sample preparation involved in speciation analysis. Sources of error in sample preparation; Efforts to develop techniques and methods of sample preparation; Objectives of the investigative efforts in method development; Examples of techniques and methods of sample preparation.

  • The efficiency of chemical vapour generation of transition and noble metals. Matoušek, Tomáš // Analytical & Bioanalytical Chemistry;Jun2007, Vol. 388 Issue 4, p763 

    The efficiency data from individual reports on chemical vapour generation (CVG) of transition and noble metals are overviewed with respect to the ways that they were obtained. The values derived from direct measurement of analyte in the gaseous phase or obtained from comparison with other sample...

  • Chemical Fingerprinting of Gardenia jasminoides Fruit Using Direct Sample Introduction and Gas Chromatography with Mass Spectrometry Detection. Shikai Van; Wenfeng Xin; Guoan Luo; Yiming Wang; Yiyu Cheng // Journal of AOAC International;Jan/Feb2006, Vol. 89 Issue 1, p40 

    The article focuses on the development of an innovative approach for chemical fingerprinting of Gardenia jasminoides fruit, based on the combination of direct sample introduction and gas chromatography analysis with mass spectrometry detection. Through application of principal components...

  • ICP-MS Detection for HPLC Analyses of Pharmaceutical Products. Shelbourn, Tim; Williamson, Leah; Gillespie, Todd; Montgomery, Robert // LC-GC North America;Feb2009, Vol. 27 Issue 2, p164 

    Experiments using inductively coupled plasma-mass spectrometry (ICP-MS) as a detection system for reversed-phase chromatographic methods have been conducted for the analyses of various pharmaceutical compounds. Interfacing the ICP-MS instrument to the high performance liquid chromatography...

  • Evaluating Optical Particle Counters.  // Laboratory Equipment;Mar2008, Vol. 44 Issue 12, p12 

    The article focuses on the use of optical particle counters (OPCs) and other electronic monitors in monitoring fluids during manufacturing process. It is argued that the use of OPC may not always be effective, however, operators have still preferred the tool. Moreover, it is noted that...

  • Investigation of the direct hydride generation nebulizer for the determination of arsenic, antimony and selenium in inductively coupled plasma optical emission spectrometry. Rojas, Illiana; Murillo, Miguel; Carrión, Nereida; Chirinos, José // Analytical & Bioanalytical Chemistry;May2003, Vol. 376 Issue 1, p110 

    A direct hydride generation nebulizer (DHGN) was explored for introduction of the sample in inductively coupled plasma–optical emission spectrometry (ICP–OES) using radially viewed mode. This simple hydride generation system was constructed in our laboratory and requires similar...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics