TITLE

Analytical investigations of poly(acrylic acid) coatings electrodeposited on titanium-based implants: a versatile approach to biocompatibility enhancement

AUTHOR(S)
De Giglio, E.; Cometa, S.; Cioffi, N.; Torsi, L.; Sabbatini, L.
PUB. DATE
December 2007
SOURCE
Analytical & Bioanalytical Chemistry;Dec2007, Vol. 389 Issue 7/8, p2055
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A polyacrylic acid film was synthesized on titanium substrates from aqueous solutions via an electroreductive process for the first time. This work was done in order to develop a versatile coating for titanium-based orthopaedic implants that acts as both an effective bioactive surface and an effective anti-corrosion barrier. The chemical structure of the PAA coating was investigated by X-ray photoelectron spectroscopy (XPS). Scanning electron microscopy (SEM) was employed to evaluate the effect of annealing treatment on the morphology of the coatings in terms of their uniformity and porosity. Inductively coupled plasma mass spectrometry was used to measure ion concentrations in ion release tests performed on Ti-6Al-4V sheets modified with PAA coatings (annealed and unannealed). Results indicate that the annealing process produces coatings that possess considerable anti-corrosion performance. Moreover, the availability and the reactivity of the surface carboxylic groups were exploited in order to graft biological molecules onto the PAA-modified titanium implants. The feasibility of the grafting reaction was tested using a single aminoacid residue. A fluorinated aminoacid was selected, and the grafting reaction was monitored both by XPS, using fluorine as a marker element, and via quartz crystal microbalance (QCM) measurements. The success of the grafting reaction opens the door to the synthesis of a wide variety of PAA-based coatings that are functionalized with selected bioactive molecules and promote positive reactions with the biological system interfacing the implant while considerably reducing ion release into surrounding tissues. [Figure not available: see fulltext.]
ACCESSION #
27657783

 

Related Articles

  • Metallic Biomaterials in Skeletal Repair. Frosch, Karl-Heinz; Stürmer, Klaus Michael // European Journal of Trauma;Apr2006, Vol. 32 Issue 2, p149 

    Metallic biomaterials are becoming increasingly important in skeletal repair. The goal of this review article is to present an overview of metallic implant materials currently used in trauma and orthopedic surgery. Further, new research trends and future clinical concepts are described and...

  • Examination of the inflammatory response following implantation of titanium plates coated with phospholipids in rats. Kochanowski, Alexandra; Hoene, Andreas; Patrzyk, Maciej; Walschus, Uwe; Finke, Birgit; Luthringer, Bérengère; Feyerabend, Frank; Willumeit, Regine; Lucke, Silke; Schlosser, Michael // Journal of Materials Science: Materials in Medicine;Apr2011, Vol. 22 Issue 4, p1015 

    Implantation of biomaterials like titanium (Ti) causes inflammatory reactions possibly affecting implant functionality. Surface modifications could improve biocompatibility and functionality of implants. Biomembrane-derived phospholipids might be useful as implant coating due to their biomimetic...

  • Biomedical Implants: Corrosion and its Prevention - A Review. Manivasagam, Geetha; Dhinasekaran, Durgalakshmi; Rajamanickam, Asokamani // Recent Patents on Corrosion Science;2010, p40 

    In the area of materials science, corrosion of biomaterials is of paramount importance as biomaterials are required for the survival of the human beings suffering from acute heart diseases, arthritis, osteoporosis and other joint complications. The present article discusses various issues...

  • Mechanical Testing of Implants' Durability Ties into the Biocompatibility of Materials.  // Orthopedic Design & Technology;Sep/Oct2011, Vol. 7 Issue 5, p44 

    The article discusses the mechanical testing of orthopedic implants in the U.S. in 2011. It tackles the difference between biocompatibility testing and longevity testing. It mentions the view of John McCloy of Accutek Testing Laboratory in Fairfield, Ohio on the acceptance criteria for the spine...

  • Role of mechanical factors in the evaluation of pedicle screw type spinal fixation devices. Goel, V. K.; Ebraheim, N. A.; Biyani, A.; Rengachary, S.; Faizan, A. // Neurology India;Dec2005, Vol. 53 Issue 4, p399 

    Prior to implantation, spinal implants are subjected to rigorous testing to ensure safety and efficacy. A full battery of tests for the devices may include many steps ranging from biocompatibility tests to in vivo animal studies. This paper describes some of the essential tests from a mechanical...

  • The Development of Wear Resistant Titanium-Ceramic Composites for Orthopaedic Implant Devices. Abkowitz, S.; Abkowitz, S. M.; Fisher, H. // Advanced Materials & Processes;Nov2004, Vol. 162 Issue 11, p82 

    Discusses the development, properties, and manufacturing of a titanium matrix composite containing TiC particles. Properties and applications of titanium matrix composites; Method for the fabrication of fully dense titanium alloy components; Improvement in wear properties of wear resistant...

  • SYNTHESIS OF TITANIUM COMPOSITE BIO-IMPLANTS. Pattanayak, Deepak K.; Mathur, Vivek; Rao, Boddapati T.; Rama Mohan, Tallapragada R. // International Journal of Powder Metallurgy;Mar/Apr2004, Vol. 40 Issue 2, p55 

    Because of their specific strength and excellent biocompatibility, titanium, titanium alloys and composites find application in the human body. The main problem resides in the consolidation of titanium powder into components with suitable properties. In the present study, Ti-bio glass composite...

  • Study shows micron-size particles generated by titanium implants.  // Advanced Materials & Processes;Jul2005, Vol. 163 Issue 7, p58 

    Discusses a research indicating that microscopic titanium particles that may weaken the bonding of hip, knee, and other joint replacements are generated by titanium implants. Key findings of the study; Implications for the biomedical materials industry.

  • SELECTION OF BIOMATERIALS FOR ORTHOPAEDIC APPLICATIONS USING THE PONDERATED PROPERTIES METHOD. Catalin, Musat; Adrian, Pacioga; Stanca, Comsa // Romanian Review Precision Mechanics, Optics & Mecatronics;2009, Vol. 19 Issue 36, p89 

    The ponderated properties method can be utilised for optimization of material selection when more properties must be taken into consideration. A pondering factor is assigned for each material specific requirement or property, depending on the importance of the property.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics