TITLE

Fibrin Glue Reduces Intra-Abdominal Adhesions to Synthetic Mesh in a Rat Ventral Hernia Model

AUTHOR(S)
Toosie, Katayoun; Gallego, Kelly
PUB. DATE
January 2000
SOURCE
American Surgeon;Jan2000, Vol. 66 Issue 1, p41
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Postoperative intra-abdominal adhesions are associated with significant morbidity and mortality. In this study, the effect of topical fibrin glue (FG) on adhesion formation in a rat model was investigated. Forty Sprague-Dawley male rats underwent midline laparotomy. Bilateral peritoneal-muscular abdominal wall defects were created and then replaced with premeasured soft tissue Goretex patches. Rats were randomized to FG sprayed over the patches or to a control group. Two observers blinded to the randomization assessed the severity of adhesions to the patch by scoring the density of adhesions (grades 0-3) and the percentage of the patch area covered by adhesions (0-100%). The mean percentage of the patch covered by adhesions was 32.8 +/- 6.1 per cent for the FG group versus 57.9 +/- 6.7 per cent for the control group (P < 0.01). The mean density of adhesions for the FG group was 0.95 (+/- .0.17) versus 2.0 (+/-.0.21) for the control group (P = 0.001). Topical FG reduces the severity and density of intra-abdominal adhesions in a rat model.
ACCESSION #
2723501

 

Related Articles

  • Evaluation of acute fixation strength of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant. Jenkins, E. D.; Melman, L.; Frisella, M. M.; Deeken, C. R.; Matthews, B. D. // Hernia;Oct2010, Vol. 14 Issue 5, p505 

    Introduction: The purpose of this study was to evaluate the acute fixation strength of fibrin sealant as an alternative fixation method for laparoscopic ventral hernia repair (LVHR) when utilized with absorbable and nonabsorbable barrier meshes. Methods: Representative mesh types for LVHR...

  • Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel®) vs. titanium tacks: a randomised controlled experimental study in pigs. Eriksen, J. R.; Bech, J. I.; Linnemann, D.; Rosenberg, J. // Hernia;Oct2008, Vol. 12 Issue 5, p483 

    The main reason for hospital stay after laparoscopic ventral hernia repair (LVHR) is probably pain, which also causes a lengthening of the patient’s time to assume normal daily activities and work. It is likely that titanium tacks may be the main contributing factor to early (and maybe...

  • Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model. Clarke, Tatyan; Katkhouda, Namir; Mason, Rodney J.; Bon C. Cheng; Algra, Jeffrey; Olasky, Jaisa; Sohn, Helen J.; Moazzez, Ashkan; Balouch, Maryam // Surgical Endoscopy;Mar2011, Vol. 25 Issue 3, p737 

    Background: The classic method of mesh fixation in laparoscopic ventral hernia repair is transfascial sutures with tacks. This method has been associated with low recurrence rates, but yields significant morbidity from pain and bleeding. Fibrin glue has been used successfully in inguinal hernia...

  • Prevention of Subcutaneous Seroma Formation in Open Ventral Hernia Repair Using a New Low-Thrombin Fibrin Sealant. Köhler, Gernot; Koch, Oliver; Antoniou, Stavros; Lechner, Michael; Mayer, Franz; Emmanuel, Klaus // World Journal of Surgery;Nov2014, Vol. 38 Issue 11, p2797 

    Background: Seroma formation is a frequent postoperative complication following open ventral hernia repair (OVHR), especially in cases requiring wide subcutaneous dissection (WSD). The aim of this study was to evaluate the effectiveness of a new low-thrombin fibrin sealant for seroma prevention....

  • The use of cyanoacrylate sealant as simple mesh fixation in laparoscopic ventral hernia repair: a large animal evaluation. Reynvoet, E.; Cleven, S.; Overbeke, I.; Chiers, K.; Baets, P.; Troisi, R.; Berrevoet, F. // Hernia;Aug2015, Vol. 19 Issue 4, p661 

    Purpose: The use of glue as mesh fixation in laparoscopic ventral hernia repair (LVHR) significantly reduces fixation associated morbidity. This experiment evaluates the intraperitoneal use of synthetic glue as single mesh fixation. Methods: A total of 21 sheep were operated using a hernia model...

  • The FDA okays the nation's first surgical 'glue.' Moore, Amy Slugg // RN;Aug98, Vol. 61 Issue 8, p20 

    Presents a summary of an article entitled `New Fibrin Sealant Approved to Help Control Bleeding in Surgery,' published in the May 1, 1998 issues of the ` Food and Drug Administration Talk Paper,' relating the to approval by the FDA of fibrin sealants.

  • Autologous Fibrin for Blepharoplasty Incisions. Madel, Mark A. // JAMA: Journal of the American Medical Association;12/15/89, Vol. 262 Issue 23, p3271 

    Comments on an article on the use of autologous fibrin for the treatment of blepharoplasty incisions.

  • Fibrin glue. Atrah, H.I. // BMJ: British Medical Journal (International Edition);4/9/94, Vol. 308 Issue 6934, p933 

    Examines the use of fibrin glue injection for hemostasis. Components of fibrin glue; Sources of fibrin glue; Value of fibrin glue for a range of surgical indications.

  • Hematology.  // Clinical & Investigative Medicine;Aug97 Supplement, Vol. 20, pS30 

    Presents an abstract of the research manuscript `A novel, automated method of cryoprecipitation to generate an autologous fibrin glue,' by G. Rock, R. Berger et al from the University of Ottawa.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics