Locking Plates: Tips and Tricks

Smith, Wade R.; Ziran, Bruce H.; Anglen, Jeff O.; Stahel, Philip F.
October 2007
Journal of Bone & Joint Surgery, American Volume;Oct2007, Vol. 89-A Issue 10, p2298
Academic Journal
The article discusses techniques and principles of locking plate fixation. Locking plates are fracture fixations devices with threaded screw holes, which allows screw to thread to the plate and function as fixed-angle device. The indications for its use include the comminuted shaft fractures, comminuted metaphyseal intra-articular fractures and short-segment metaphyseal fractures.


Related Articles

  • Surgical Treatment of Three and Four-Part Proximal Humeral Fractures. Solberg, Brian D.; Moon, Charles N.; Franco, Dennis P.; Paiement, Guy D. // Journal of Bone & Joint Surgery, American Volume;Jul2009, Vol. 91-A Issue 7, p1689 

    Background: Optimal surgical management of three and four-part proximal humeral fractures in osteoporotic patients is controversial, with many advocating prosthetic replacement of the humeral head. Fixed-angle locked plates that maintain angular stability under load have been proposed as an...

  • Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description. Janicek, John C.; Carson, William L.; Wilson, David A. // Journal of Orthopaedic Surgery & Research;2007, Vol. 2, p21 

    The purpose of this investigation was to design and verify the capabilities of an in vitro loading-measurement system that mimics in vivo unconstrained three dimensional (3D) relative motion between long bone ends, applies uniform load components over the entire length of a test specimen, and...

  • Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates. OZKAYA, UFUK; BILGILI, FUAT; KILIC, AYHAN; PARMAKSIZOGLU, ATILLA SANCAR; KABUKCUOGLU, YAVUZ // Hip International;Apr-Jun2009, Vol. 19 Issue 2, p141 

    The efficacy of the reverse Less Invasive Plating System in the management of unstable proximal femoral extracapsular fractures was retrospectively evaluated. Twenty-seven patients with complex proximal femoral fractures were identified. There were three open fractures. The mean age was 71 years...

  • �z�letbe hatol� proximalis tibiat�r�sek ell�t�sa Doliaxialis NCB lemezzel. GERGELY, NOT L�SZL�; ZOLT�N, KISS // Magyar Traumatol�gia, Ortop�dia, K�zseb�szet, Plasztikai;2012, Vol. 55 Issue 3, p159 

    Of all long bone fractures in adults, only 10% involve the proximal tibia. Despite of the advanced implants and surgical technique, proximal tibia fractures involving articular surface, especially AO/OTA C-types, still remain a great challenge for the surgeon. The purpose of the study was to...

  • Zimmer reports implanting its first NCB plating system. PEDERSEN, AMANDA // Medical Device Daily;8/13/2010, Vol. 14 Issue 157, p1 

    The article reports on the first implantation of Zimmer's Non-Contact Bridging (NCB) Periprosthetic Plating System. The company claims that periprosthetic fracture care could be revolutionized by its new orthopedic trauma product. The full release of the device is scheduled in Fall 2010. The...

  • Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates. Ganesh, VK; Ramakrishna, K; Ghista, Dhanjoo N // BioMedical Engineering OnLine;2005, Vol. 4, p46 

    Background: In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the...

  • The treatment of proximal humeral fractures with intramedullary titanium helix wire by 97 patients. Gorschewsky, Ottmar; Puetz, Andrej; Klakow, Andreas; Pitzl, Martin; Neumann, Wolfram // Archives of Orthopaedic & Trauma Surgery;Dec2005, Vol. 125 Issue 10, p670 

    Introduction: The displaced proximal humeral fracture continues to be a problem and remains the �unsolved fracture�. Many guidelines for surgical treatment of different types of these fractures have been described. A conservative functional therapy is recommended as well as a closed or...

  • Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage. Martetschläger, Frank; Kraus, Tobias; Schiele, Clara; Sandmann, Gunther; Siebenlist, Sebastian; Braun, Karl; Stöckle, Ulrich; Freude, Thomas; Neumaier, Markus // Knee Surgery, Sports Traumatology, Arthroscopy;May2013, Vol. 21 Issue 5, p1189 

    Purpose: The purpose of the current study was to assess the clinical and radiological results after locking T-plate osteosynthesis with coracoclavicular augmentation of unstable and displaced distal clavicle fractures (Neer type 2). Methods: Thirty patients, treated between January 2007 and...

  • Comparison of Surgical Outcomes of Intra-Articular Calcaneal Fractures by Age. Gaskill, Trevor; Schweitzer, Karl; Nunley, James // Journal of Bone & Joint Surgery, American Volume;12/15/2010, Vol. 92-A Issue 18, p2884 

    Background: Internal fixation is an accepted treatment for displaced fractures of the calcaneus. Operative intervention in older patients, however, is traditionally discouraged in the literature. The purpose of this study was to compare the outcomes of internal fixation of intra-articular...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics