TITLE

Clavicular Anatomy and the Applicability of Precontoured Plates

AUTHOR(S)
Huang, Jerry I.; Toogood, Paul; Chen, Michael R.; Wilber, John H.; Cooperman, Daniel R.
PUB. DATE
October 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Oct2007, Vol. 89-A Issue 10, p2260
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Plate fixation of clavicular fractures is technically difficult because of the complex anatomy of the bone, with an S-shaped curvature and a cephalad-to-caudad bow. The purpose of the present study was to characterize variations in clavicular anatomy and to determine the clinical applicability of an anatomic precontoured clavicular plate designed for fracture fixation. Methods: One hundred pairs of clavicles were analyzed. The location and magnitude of the superior clavicular bow were determined with use of a digitizer and modeling software. Axial radiographs were made of each clavicle and the precontoured Acumed Locking Clavicle Plate, which is designed to be applied superiorly. With use of Adobe Photoshop technology, the plates were freely translated and rotated along each clavicle to determine the quality of fit and the location of the ‘best fit’. Results: The location of the maximum superior bow was lateral, with a mean distance of 37.2 ± 18.4 mm from the acromial articulation and with a mean magnitude of 5.1 ± 5.9 mm. There was no significant difference in the location or magnitude of the apex of the bow between specimens from male and female donors. The anatomic precontoured clavicular plate had the best fit in specimens from black male donors and the worst fit in specimens from white female donors, with a poor fit being seen in 38% (nineteen) of the fifty specimens from white female donors. The best location for superior plate application was along the medial aspect of the clavicle. Conclusions: The apex of the superior bow of the clavicle is typically located along the lateral aspect of the bone, whereas the medial aspect of the superior surface of the clavicle remains relatively flat, making it an ideal plating surface. The precontoured anatomic clavicular plate appears to fit the S-shaped curvature on the superior surface of the majority of clavicles in male patients but may not be as conforming in white female patients. While this plate fits in the medial three-fifths of the clavicle, it does not fit as well laterally. Clinical Relevance: Recent studies have shown that displaced midshaft clavicular fractures that are treated with plate fixation have better functional outcomes than those that are treated nonoperatively. An understanding of clavicular anatomy is paramount for optimal plate design and fracture fixation. Our data provide potentially important information for future clavicular plate designs and applications.
ACCESSION #
27094003

 

Related Articles

  • Surgical Treatment of Post-Radiotherapy Nonunions of the Clavicle. Wera, Glenn; Mohler, David Glenn; Chou, Loretta // Bulletin of the NYU Hospital for Joint Diseases;2005, Vol. 62 Issue 3/4, p125 

    Fractures of irradiated bones present special challenges to healing. Nonunions are very common and are challenging surgical problems. We report three radiated nonunions of the clavicle successfully treated with modifications of standard internal fixation techniques.

  • Locking Plates: Tips and Tricks. Smith, Wade R.; Ziran, Bruce H.; Anglen, Jeff O.; Stahel, Philip F. // Journal of Bone & Joint Surgery, American Volume;Oct2007, Vol. 89-A Issue 10, p2298 

    The article discusses techniques and principles of locking plate fixation. Locking plates are fracture fixations devices with threaded screw holes, which allows screw to thread to the plate and function as fixed-angle device. The indications for its use include the comminuted shaft fractures,...

  • Surgical Treatment of Three and Four-Part Proximal Humeral Fractures. Solberg, Brian D.; Moon, Charles N.; Franco, Dennis P.; Paiement, Guy D. // Journal of Bone & Joint Surgery, American Volume;Jul2009, Vol. 91-A Issue 7, p1689 

    Background: Optimal surgical management of three and four-part proximal humeral fractures in osteoporotic patients is controversial, with many advocating prosthetic replacement of the humeral head. Fixed-angle locked plates that maintain angular stability under load have been proposed as an...

  • Locking plates have increased torsional stiffness compared to standard plates in a segmental defect model of clavicle fracture. Will, Ryan; Englund, Richard; Lubahn, John; Cooney, Timothy E. // Archives of Orthopaedic & Trauma Surgery;Jun2011, Vol. 131 Issue 6, p841 

    Objective: To evaluate the effect of locked plate technology to resist torsion in a clavicle fracture model of segmental bone loss. Methods: Forty-four synthetic clavicles were repaired with either 3.5 mm locked compression plate (LCP) or 3.5 mm low-contact dynamic compression plate (LCDCP)....

  • Fractures of the Clavicle. Yochum, Terry R.; Maola, Chad J. // American Chiropractor;Feb2005, Vol. 27 Issue 2, p12 

    This article focuses on a case history of a young patient, who fell on an outstretched arm while playing football. The "S" shape and normal overlap with the upper ribcage renders the clavicle a difficult structure to evaluate on straight anteroposterior projections. The most optimum view is...

  • Locking plates for displaced fractures of the lateral end of clavicle: Potential pitfalls. Sajid, Soha; Fawdington, Ross; Sinha, Maneesh // International Journal of Shoulder Surgery;Oct-Dec2012, Vol. 6 Issue 4, p126 

    Roughly a quarter of all clavicle fractures occur at the lateral end. Displaced fractures of the lateral clavicle have a higher rate of nonunion. The management of fractures of the lateral clavicle remains controversial. Open reduction internal fixation with a superiorly placed locking plate is...

  • Fibular allograft and anterior plating for dislocations/fractures of the cervical spine. Ramnarain, A.; Govender, S. // Indian Journal of Orthopaedics;Jan-Mar2008, Vol. 42 Issue 1, p83 

    Background: Subaxial cervical spine dislocations are common and often present with neurological deficit. Posterior spinal fusion has been the gold standard in the past. Pain and neck stiffness are often the presenting features and may be due to failure of fixation and extension of fusion mass....

  • Outcomes of Posterior Wall Fractures of the Acetabulum. Moed, Berton R.; Mcmichael, Jessica C. // Journal of Bone & Joint Surgery, American Volume;Mar2008 Supplement, Vol. 90-A, p87 

    BACKGROUND: The Musculoskeletal Function Assessment (MFA) is a validated, reliable, self-administered questionnaire that is useful for determining functional status. The Merle d'Aubigné score is a clinical measure of hip function. The purpose of the present study was to evaluate the outcome...

  • Risk factors for nonunion in 337 displaced midshaft clavicular fractures treated with Knowles pin fixation. Wu, Chih-Lung; Chang, Hui-Chin; Lu, Ko-Hsiu // Archives of Orthopaedic & Trauma Surgery;Jan2013, Vol. 133 Issue 1, p15 

    Background: Clavicular fractures account for nearly 10 % of all fractures, and the majority of those fractures involve the midshaft. Historically, these fractures were treated nonoperatively; however, recent data suggest an increased risk of nonunion and symptomatic malunion for displaced,...