TITLE

The Economic Impact of Reprocessing External Fixation Components

AUTHOR(S)
Horwitz, Daniel S.; Schabel, Kathryn L. S.; Higgins, Thomas F.
PUB. DATE
October 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Oct2007, Vol. 89-A Issue 10, p2132
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: The trend toward temporizing external fixation of complex fractures has resulted in increased expenditures for these devices. Increasing pressure to reduce health-care expenditures has led to exploration of reuse of equipment intended for single use. Devices must be tested and recertified prior to redeployment in hospital stock. We report the rate of manufacturer recertification and institutional cost savings associated with a reuse program approved by the United States Food and Drug Administration. Methods: All Hoffmann-II external fixation components that had been removed at our institution during the study period were submitted to the manufacturer for visual inspection and mechanical testing. Pass rates for original components and previously recycled components were determined. With use of a conservative pass rate and the assumption of a maximum of three recertifications of each component, the total potential hospital savings on external fixation were calculated. Results: The first pass rate was 76%. The second pass rate (i.e., the rate for components that had already been recertified once and had been sent for a second recertification) was 83%, but that rate was derived from a limited sample. On the basis of a conservative pass-rate estimate of 75%, the predicted average number of uses of a recyclable component was 2.7. The recertified components were sold back to our hospital at 50% of the original price. Because carbon-fiber bars and half-pins are not recycled, 85% of the charges expended on a new external fixation component are spent on portions of the system that are recyclable. The potential total savings on reusable components was found to be 32%, with a total savings of 27% for the whole external fixation system. No recertified components failed in clinical use over the course of the study. Conclusions: With the expansion of cost-control efforts, the recycling of medical devices appears inevitable. Previous data have demonstrated the safety of reuse of external fixation devices, and this study confirms that finding. Our paper demonstrates the real cost savings associated with a manufacturer-based testing and recertification program. Issues of voluntary participation in reuse programs, component ownership, and the impact of savings on patient charges are yet to be worked out by individual institutions. Level of Evidence: Economic and decision analysis, Level II. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
27093986

 

Related Articles

  • SICOT contribution to natural disaster assistance: the external fixator. Hinsenkamp, Maurice // International Orthopaedics;Aug2014, Vol. 38 Issue 8, p1549 

    The article discusses the benefits of using the external fixator to fix fractures during natural disaster assistance, such as after the Haiti earthquake in 2010. Bone healing is considered as the main advantage of external fixators. The principles of using external fixators, particularly in a...

  • Lečenje zatvorenih preloma pilona tibije kombinacijom dinami7#x010D;ke spoljne skeletne fiksacije i minimalnom unutraÅ¡njom fiksacijom. Golubović, Zoran; Mačukanović-Golubović, Lana; Stojiljković, Predrag; Jovanović, Jovica; Micić, Ivan; Stojiljković, Danilo; Milić, Dragan; Mitković, Milorad // Vojnosanitetski Pregled: Military Medical & Pharmaceutical Journ;May2007, Vol. 64 Issue 5, p307 

    Background/Aim. Intraarticular fractures of the tibial plafond (pilon fractures) belong to the group of most severe fractures. They are usually caused by high-energy trauma and frequently associated with a marked soft-tissue damage. Surgical treatment has replaced the traditional nonoperative...

  • External Fixation: How to Make It Work. Ziran, Bruce H.; Smith, Wade R.; Anglen, Jeff O.; Tornetta III, Paul // Journal of Bone & Joint Surgery, American Volume;Jul2007, Vol. 89-A Issue 7, p1620 

    The article discusses the principles of external fixation in the U.S. The problems encountered with external fixation in the late twentieth century were predominantly due to a lack of understanding of the principles of application, the principles of fracture-healing with external fixation, and...

  • Fatigue behavior of Ilizarov frame versus tibial interlocking nail in a comminuted tibial fracture model: a biomechanical study. Hasenboehler, Erik; Smith, Wade R.; Laudicina, Laurence; Philips, Giby C.; Stahel, Philip F.; Morgan, Steven J. // Journal of Orthopaedic Surgery & Research;2006, Vol. 1, p16 

    Background: Treatment options for comminuted tibial shaft fractures include plating, intramedullary nailing, and external fixation. No biomechanical comparison between an interlocking tibia nail with external fixation by an Ilizarov frame has been reported to date. In the present study, we...

  • External fixation of complex femoral shaft fractures. Zlowodzki, M.; Prakash, J.; Aggarwal, N. // International Orthopaedics;Jun2007, Vol. 31 Issue 3, p409 

    Conversion of temporary external fixation to an intramedullary nail within the first 2 weeks after a femoral shaft fracture is standard practice. However, due to financial constraints, in large parts of the world external fixation of femoral shaft fractures is often the definitive treatment. Out...

  • Evidence-Based Orthopaedics.  // Journal of Bone & Joint Surgery, American Volume;Aug2004, Vol. 86-A Issue 8, p1835 

    This article examines whether complication rates differs between daily and weekly pin-site care in patients in whom an external fixator has been used to stabilize a high tibial osteotomy in the treatment of gonarthrosis of the knee. 50 patients undergoing surgery for gonarthrosis by the...

  • The Sliding Hip Screw Is Better Than Short Femoral Nails for Extracapsular Femoral Fracture.  // Journal of Bone & Joint Surgery, American Volume;Aug2004, Vol. 86-A Issue 8, p1836 

    This article compares the efficacy of cephalocondylic intramedullary nails with that of extramedullary fixation implants, in patients with extracapsular proximal femoral fractures. Studies were identified by searching the Cochrane Musculoskeletal Injuries Group trials register. Pooling the...

  • An external fixation device: preliminary communication. Sukhtian, Walid; Hughes, Sean // Journal of the Royal Society of Medicine;Nov1979, Vol. 72 Issue 11, p831 

    The article cites a study that examines the effectiveness of an external fixation device in treating fractures. A new external fixation device, which is easy to apply and is relatively inexpensive, has been developed. In applying the device, the technique used is through the exposure of the...

  • Hemicallotasis for correction of varus deformity of the proximal tibia using a unilateral external fixator. Chang-Wug Oh; Sung-Jung Kim; Sung-Ki Park; Hee-June Kim; Hee-Soo Kyung; Hwan-Sung Cho; Byung-Chul Park; Joo-Chul Ihn // Journal of Orthopaedic Science;Jan2011, Vol. 16 Issue 1, p44 

    Background: Gradual correction of varus deformity of the proximal tibia is generally accepted and produces good results. However, most studies have used circular external fixators, which are complex and cause patient discomfort. This study was undertaken to determine the efficacy of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.