TITLE

Dosimetric evaluation of a new collimator insert system for stereotactic radiotherapy

AUTHOR(S)
T Paschalis; P Sandilos; E Tatsis; P Karaiskos; C Antypas; C Chatzigiannis; K Dardoufas; E Georgiou; L Vlachos
PUB. DATE
June 2007
SOURCE
British Journal of Radiology;Jun2007, Vol. 80 Issue 954, p446
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The prototype of a stereotactic collimator set developed in our department is evaluated for clinical use. This set consists of three cylindrical blocks mounted on a tray which slides in the wedge insert of a Siemens Primus accelerator. Each block has a collimating hole along its long axis to produce radiation fields of circular cross-section at the isocentre plane with diameters of 15 mm, 20 mm and 25 mm. Different geometric and dosimetric quality assurance tests were performed and results are found within the limits set for stereotactic radiotherapy. Dosimetry results measured using Kodak EDR-2 radiographic film and a pinpoint ion chamber also show good agreement with corresponding results calculated by Monte Carlo simulation of the linear accelerator head and the collimators. Measured dosimetry data were used to adapt a conventional PLATO treatment planning system for stereotactic radiotherapy using the prototype collimator set. Treatment planning system calculations and film measurements for treatment of an intracranial lesion in an anthropomorphic head phantom using coplanar 180 degrees arcs are compared and found to agree within 2 mm. This supports the accuracy of dose delivery using the prototype stereotactic collimators. Despite their increased penumbra (2.5-3.5 mm relative to 2-2.5 mm for commercially available collimators) the ease of construction makes the proposed stereotactic collimators an interesting alternative for accomplishing cost effective stereotactic treatments.
ACCESSION #
27008575

 

Related Articles

  • Respective roles of scatter, attenuation, depth-dependent collimator response and finite spatial resolution in cardiac single-photon emission tomography quantitation: a Monte Carlo study. El Fakhri, Georges N.; Buvat, Irène; Pélégrini, Mélanie; Benali, Habib; Almeida, Pedro; Bendriem, Bernard; Todd-Pokropek, Andrew; Di Paola, Robert // European Journal of Nuclear Medicine;1999, Vol. 26 Issue 5, p437 

    Abstract. The purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic...

  • Progress in the conceptual development of the ITER vertical neutron collimator. Tsutskikh, A.; Prosvirin, D.; Krasil’nikov, A.; Walker, C. // Instruments & Experimental Techniques;Mar2006, Vol. 49 Issue 2, p174 

    Monte-Carlo calculations of the fluxes of forward and scattered neutrons at points of arrangement of the detectors for the analyzed design of the ITER multichannel vertical neutron collimator have been performed with the MCNP model. A concept of a vertical neutron collimator positioned in the...

  • The use of multichannel collimation in small-angle neutron scattering: a computer-simulation study. Falcão, A.N.; Margaça, F.M.A.; Carvalho, F.G. // Applied Physics A: Materials Science & Processing;Dec2002 Supplement, Vol. 74 Issue 6, ps1462 

    A Monte Carlo computer simulation was performed to evaluate the use of converging multichannel collimation in a small-angle neutron-scattering arrangement, giving guidelines for the construction of a first prototype. The neutron-absorbing efficiency as well as the divergence of the incoming beam...

  • Angular distributions of electrons transmitted ballistically through tapered constrictions. Hornsey, R. I. // Journal of Applied Physics;6/15/1996, Vol. 79 Issue 12, p9172 

    Presents a study on the angular distribution of electrons injected ballistically through constrictions with a variety of simple geometries and specularity coefficients using a Monte Carlo approach. Examples of novel physics provided by the electronic devices which exploit the ballistic...

  • Simulation of bent crystal spectrometers. Kyrala, George A. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p815 

    In crystal spectrometers one traditionally labels each position in the dispersion/recording plane by a single wavelength value. A simple examination of the crystal spectrometers shows that different areas of the crystal contribute different wavelengths at the same position in the recording...

  • Commissioning and quality assurance of a commercial intensity modulated radiotherapy (IMRT) treatment planning system PrecisePLAN. Pelagade, Satish; Thakur, Kalpana; Bopche, Tushar; Bhavsar, Devang; Patel, Daxa; Shah, Ruchita; Vyas, Rakeshkumar // Turkish Journal of Cancer;Jan2007, Vol. 37 Issue 1, p22 

    The objective of this paper is to present our experience in the commissioning and quality assurance (QA) of PrecisePLAN treatment planning system for intensity modulated radiotherapy (IMRT) using multileaf collimator (MLC), step and shoot technique. The data were obtained during the...

  • MARS14 Collimation and Shielding Studies for the 3 GeV Ring of J-PARC Project. Nakao, Noriaki; Mokhov, Nikolai; Yamamoto, Kazami; Irie, Yoshiro; Drozhdin, Alexander // AIP Conference Proceedings;2003, Vol. 693 Issue 1, p158 

    MARS14 Monte Carlo simulations were performed for collimation and shielding studies of the J-PARC 3 GeV ring. A 400 MeV proton beam loss distribution, calculated with the STRUCT code, was used as a source term. The module locations in the ring and the curved tunnel sections were described by the...

  • Beam Loss Control on the ISIS Synchrotron: Simulations, Measurements, Upgrades. Warsop, C. M. // AIP Conference Proceedings;2003, Vol. 693 Issue 1, p154 

    The ISIS 800 MeV proton synchrotron presently provides 2.5×1013 protons per pulse at 50 Hz, corresponding to a mean power of 160 kW. A dual harmonic RF system upgrade, now being installed, is expected to increase the intensity and power to about 3.75×1013 ppp and 240 kW respectively....

  • Varying Collimation for Dark-Field Extraction. Ge Wang; Wenxiang Cong; Haiou Shen; Yu Zou // International Journal of Biomedical Imaging;2009, Special section p1 

    Although x-ray imaging is widely used in biomedical applications, biological soft tissues have small density changes, leading to low contrast resolution for attenuation-based x-ray imaging. Over the past years, x-ray small-angle scattering was studied as a new contrast mechanism to enhance...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics