TITLE

Ultraviolet Lighting During Orthopaedic Surgery and the Rate of Infection

AUTHOR(S)
Ritter, Merrill A.; Olberding, Emily M.; Malinzak, Robert A.
PUB. DATE
September 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Sep2007, Vol. 89-A Issue 9, p1935
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Ultraviolet lighting is an alternative to laminar airflow in the operating room that may be as effective for lowering the number of environmental bacteria and possibly lowering infection rates by killing the bacteria rather than simply reducing the number at the operative site. The purpose of the present study was to compare the infection rates following joint replacement procedures performed by one orthopaedic surgeon with and without the use of ultra- violet lighting. Methods: From July 1986 to July 2005, one surgeon performed 5980 total joint replacements at one facility. In September 1991, ultraviolet lighting was installed in the operating rooms. All procedures that were performed before the installation of the ultraviolet lighting utilized horizontal laminar airflow, whereas all procedures that were performed after that date utilized ultraviolet lighting without laminar airflow. Factors associated with the rate of infection were analyzed. Results: Over a nineteen-year period, forty-seven infections occurred following 5980 joint replacements. The infection rate without ultraviolet lighting (and with laminar airflow) was 1.77%, and the infection rate with ultraviolet lighting was 0.57% (p < 0.0001). The odds of infection were 3.1 times greater for procedures performed without ultraviolet lighting (and with laminar airflow) as compared with those performed with only ultraviolet lighting (p < 0.0001). The infection rate associated with total hip replacement decreased from 1.03% to 0.72% (p = 0.5407), and the infection rate associated with total knee replacement decreased from 2.20% to 0.50% (p < 0.0001). Revision surgery, previous infection, age, total body mass index, use of cement, disease, and diagnosis were not associated with an elevated infection rate. Conclusion: When appropriate safety precautions are taken, ultraviolet lighting appears to be an effective way to lower the risk of infection in the operating room during total joint replacement surgery.
ACCESSION #
26613654

 

Related Articles

  • Titanium hemiarthroplasty of the 1st metatarsophalangeal joint. Chaudhry, A.G.; Aldadah, Q.; Fitzgerald, B. // Journal of the Royal College of Surgeons of Edinburgh;Oct99, Vol. 44 Issue 5, p335 

    Presents an abstract of the study 'Titanium Hemiarthroplasty of the 1st Metatarsophalangeal Joint,' by A.G. Chaudhry, Q. Aldadah and B. Fitzgerald, which was presented at the Joint Meeting of the Royal College of Physicians of Edinburgh and the Royal College of Surgeons of Edinburgh, with the...

  • VERTEBROPLASTIA ÃŽN TRATAMENTUL FRACTURILOR OSTEOPOROTICE: EXPERIENŢĂ PROPRIE. Sopon, M.; Matei, C.; Baier, I.; Lupean, A. // Acta Medica Transilvanica;dec2011, Vol. 2 Issue 4, p108 

    The aim of this study is to emphasize the effects of vertebroplasty from the clinical point of view and the influence on the adjacent joints. Materials and methods: Between 2009 and 2010 we conducted 9 vertebroplasty procedures the level of T12 to L3. To follow-up patients both before and after...

  • Tibial plateau fractures treated with plate fixation: to lock or not to lock. Russell, Nicholas; Tamblyn, Peter; Jaarsma, Ruurd // European Journal of Orthopaedic Surgery & Traumatology;Feb2009, Vol. 19 Issue 2, p75 

    This retrospective study with follow-up was undertaken to compare postoperative results and functional outcomes of tibial plateau fractures treated with non-locking and locking plate fixation. Over a 5-year period, 60 tibial plateau fractures were treated with plate fixation. Fracture...

  • The Oxford phase III unicompartmental knee replacement in patients less than 60 years of age. Kort, Nanne; Raay, Jos; Horn, Jim // Knee Surgery, Sports Traumatology, Arthroscopy;May2007, Vol. 15 Issue 4, p356 

    Treatment of younger patients with medial unicompartmental disease of the knee joint remains a challenging therapeutic dilemma. With the refinement of implant design, fixation and the minimally invasive techniques employed with unicompartmental knee replacement, indications have expanded to...

  • Slightly better load to failure with one vs. two suture anchors for type II SLAP repairs. Rapp, Susan M. // Orthopedics Today;Feb2008, Vol. 28 Issue 2, p79 

    The article provides information on a study which compared one double-loaded suture anchor and two single-loaded anchors for arthropscopic repair of simple type II superior labral anterior posterior lesions. Orthopedic surgeon Eric C. McCarty presented the findings during the International...

  • Capsulotomy offers increased exposure, accuracy with advanced hip arthroscopy. Rapp, Susan M. // Orthopedics Today;Jan2011, Vol. 31 Issue 1, p46 

    The article reports on the claim by Doctor Thomas G. Sampson that capsulotomy in conjunction with hip arthroscopy can be used to treat degenerative arthritis cases, for femoroacetabular impingement or when large loose bodies need to be removed from the joint.

  • Keller's Arthroplasty with Proximal Metatarsal Opening Wedge Osteotomy in Treating Severe Hallux Valgus Deformity - Surgical Techniques and Case Report. Jurdana, Hari; Gulan, Gordan; Šestan, Branko; Legović, Dalen; Šantić, Veljko; Ravlić-Gulan, Jagoda; Roth, Sandor // Collegium Antropologicum;Sep2009, Vol. 33 Issue 3, p955 

    The paper presents an operative technique proposed for treating severe Hallux Valgus deformity with arthrosis of the first metatarsal joint in elderly people. The procedure consists of the Keller's arthroplasty in combination with basal osteotomy of the first metatarsal bone, whereby the head of...

  • K-wire transfixation or distraction following the Keller-Brandes arthroplasty in Hallux rigidus and Hallux valgus? Reize, P.; Schanbacher, J.; Wülker, N. // International Orthopaedics;Jun2007, Vol. 31 Issue 3, p325 

    A total of 118 feet with Hallux valgus and Hallux rigidus treated by the Keller-Brandes method were re-examined clinically and radiologically after 9.1 years (range: 1.7-24.3). Correction of the Hallux valgus angle was obtained from an average of 40° to 23° in the Hallux valgus group....

  • MINIMAL-INCISION TOTAL HIP ARTHROPLASTY. Goldstein, Wayne M.; Branson, Jill J.; Berland, Kimberly A.; Gordon, Alexander C. // Journal of Bone & Joint Surgery, American Volume;Nov2003 Supplement 4, Vol. 85-A, p33 

    The article reports on a study which examines the practicality of the minimal-incision technique in total hip arthroplasty. The authors studied the results of 170 total hip arthroplasties performed during a one-year time period. The results indicated that 96 percent of patients in the minimal...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics