TITLE

Removal of Painful Orthopaedic Implants After Fracture Union

AUTHOR(S)
Minkowitz, Reuven B.; Bhadsavle, Siraj; Walsh, Michael; Egol, Kenneth A.
PUB. DATE
September 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Sep2007, Vol. 89-A Issue 9, p1906
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Persistent pain in the region of implanted hardware following fracture fixation commonly leads to implant removal. This prospective study evaluated patient outcomes and pain reduction following removal of orthopaedic hardware implanted for fracture fixation. Methods: Sixty patients who had been treated previously for a fracture and complained of pain in the region of the fracture fixation hardware constituted the study cohort. Patients were carefully examined by the treating physician to rule out other causes of pain such as infection and nonunion. Baseline data were recorded preoperatively. Data obtained postoperatively at three, six, and twelve months included a visual analog pain scale score and results on the Short Musculoskeletal Function Assessment Questionnaire and the Medical Outcomes Study Short Form-36. At the one-year interval, a patient satisfaction questionnaire was completed and outcomes were analyzed. Results: There were no complications associated with implant removal surgery. Three patients did not have complete follow-up, leaving a total of fifty-seven patients with complete follow-up. At one year, all patients indicated that they were satisfied, that they would have the procedure done again, and that their overall function had improved. The scores for pain on the visual analog scale decreased from a mean (and standard deviation) of 5.5 ± 2.5 before hard- ware removal to 1.3 ± 1.8 after hardware removal, with an overall improvement at one year of 76% (p = 0.00001). At one year, thirty (53%) of the fifty-seven patients had complete resolution of pain. In addition, the results on the Short Musculoskeletal Function Assessment Questionnaire showed a 43% improvement from baseline (p = 0.0001), and the results on the physical component of the Short Form-36 showed a similar improvement of 40% (p = 0.0001). Conclusions: Following fracture-healing, removal of hardware is safe with minimal risk. Improvement in pain relief and function can be expected.
ACCESSION #
26613650

 

Related Articles

  • FAILURE OF LCP CONDYLAR PLATE FIXATION IN THE DISTAL PART OF THE FEMUR. VALLIER, HEATHER A.; HENNESSEY, THERESA A.; SONTICH, JOHN K.; PATTERSON, BRENDAN M. // Journal of Bone & Joint Surgery, American Volume;Apr2006, Vol. 88-A Issue 4, p846 

    The article describes and examines six cases of failure of the Locking Compression Plate (LCP) condylar plate fixation in the distal part of the femur. The LCP condylar plate represents an evolutionary approach to the surgical intervention of distal femoral fractures. However, it fails to...

  • Comparison of various surgical methods in the treatment of implant-related infection. Şener, Muhittin; Kazimoglu, Cemal; Karapınar, Hasan; Günal, İzge; Afşar, İlhan; Karataş Şener, Aslı // International Orthopaedics;Mar2010, Vol. 34 Issue 3, p419 

    The treatment of implant-related infections is troublesome. This study was conducted to compare the effectiveness of three different surgical modalities in the treatment of implant-related infection. A total of 32 Wistar albino rats were randomised into four groups after the establishment of...

  • Causes of Failure of Ceramic-on-Ceramic and Metal-on-Metal Hip Arthroplasties. Porat, Manny; Parvizi, Javad; Sharkey, Peter; Berend, Keith; Lombardi, Adolph; Barrack, Robert // Clinical Orthopaedics & Related Research;Feb2012, Vol. 470 Issue 2, p382 

    Background: Few large series of hard bearing surfaces have reported on reasons for early failure. A number of unique mechanisms of failure, including fracture, squeaking, and adverse tissue reactions, have been reported with these hard bearing surfaces. However, the incidence varies among the...

  • Use of leg positioning holders. Richardson, Caroline // British Journal of Perioperative Nursing;Mar2004, Vol. 14 Issue 3, p127 

    Provides information about Direct Placement Leg Holders, used in lower limb internal fixation for fractures. Brief history of how and why their potential use in orthopedic trauma; Benefits for patient care and how they can improve patient positioning; Benefits for practitioners acting as...

  • Experiment study on fracture fixation with low rigidity titanium alloy. Sumitomo, Nozomu; Noritake, K.; Hattori, T.; Morikawa, K.; Niwa, S.; Sato, K.; Niinomi, M. // Journal of Materials Science: Materials in Medicine;Apr2008, Vol. 19 Issue 4, p1581 

    In order to investigate bone tissue reaction to the low rigidity titanium alloy of TNTZ in bone plate fixation, animal experiment with rabbit was performed with X-ray follow-up and histological observation. Experimental fractures were made in rabbit tibiae, and fixed by different bone plates of...

  • Biomechanical considerations in ‘biological’ femoral osteosynthesis: an experimental study of the ‘bridging’ and ‘wave’ plating techniques. Karnezis, I. A. // Archives of Orthopaedic & Trauma Surgery;May2000, Vol. 120 Issue 5/6, p272 

    Although traditional compression plate fixation aims to abolish interfragmentary movement and achieve primary bone healing, the more recent ‘biological’ plate fixation methods such as the ‘bridging’ and ‘wave’ plate techniques aim to maintain fracture...

  • Do all displaced midshaft clavicle fractures need surgery? McKee, Jennie // AAOS Now;Jun2011, Vol. 5 Issue 6, p1 

    The article focuses on the advantages and disadvantages of treating a displaced midshaft clavicle fracture with an open reduction and internal fixation (ORIF) surgery. According to research studies, ORIF allows athletes with displaced midshaft clavicle fractures to recover faster and return to...

  • Can Normal Fracture Healing Be Achieved When the Implant Is Retained on the Basis of Infection? An Experimental Animal Model. Bilgili, Fuat; Balci, Halil; Karaytug, Kayahan; Sariyilmaz, Kerim; Atalar, Ata; Bozdag, Ergun; Tuna, Meral; Bilgic, Bilge; Gurler, Nezahat // Clinical Orthopaedics & Related Research;Oct2015, Vol. 473 Issue 10, p3190 

    Background: Infection after open fractures is a common complication. Treatment options for infections developed after intramedullary nailing surgery remain a topic of controversy. We therefore used a rat fracture model to evaluate the effects of infection on osseous union when the implant was...

  • Treatment for Trochanteric Fracture of the Femur with Short Femoral Nail: A Comparison between the Asian Intramedullary Hip Screw (IMHS) and the Conventional IMHS. Hidemi Kawaji; Takuya Uematsu; Ryosuke Oba; Yoshihiko Satake; Naoya Hoshikawa; Shinro Takai // Journal of Nippon Medical School;2016, Vol. 83 Issue 3, p113 

    Introduction: We usually use short femoral nails for the treatment of trochanteric fracture of the femur. In this retrospective study, we investigated and compared the clinical results of the conventional intramedullary hip screw (IMHS) and the Asian IMHS, which is a redesigned version of the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics