TITLE

A three-dimensional echocardiographic comparison of a deep pericardial stitch versus an apical suction device for heart positioning during beating heart surgery

AUTHOR(S)
George, Shane J.; Kapetanakis, Emmanouil I.; Dhadwal, Kulwant; Al-Ruzzeh, Sharif; Rigopoulou, Efrossyni; Bulanade, Marciano; Athanasiou, Thanos; Amrani, Mohamed
PUB. DATE
October 2007
SOURCE
European Journal of Cardio-Thoracic Surgery;Oct2007, Vol. 32 Issue 4, p604
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract: Background: Heart positioning during beating heart surgery produces significant haemodynamic compromise either when a deep pericardial stitch (DPS) or apical suction devices (ApSDs) are used. In this study the two techniques’ haemodynamic performance and effect on intracardiac structures were compared through transoesophageal echocardiography (TEE) obtained volume measurements and three-dimensional ventricular and mitral valve computer reconstructions. Methods: Sequential 0° to 180° TEE images of the left heart were obtained in 10 patients undergoing beating heart surgery. Measurements with both techniques in three different positions were obtained: at baseline, the heart elevated to access its inferior surface and the heart elevated and rotated to access its lateral surface. Three-dimensional computer reconstructions of the mitral valve and the left heart were generated. Ventricular volume measurements were used to calculate stroke volume, ejection fraction and differences from baseline. An analysis of variance between each technique in all three positions was performed. Results: Central venous, left atrial and pulmonary artery pressures were significantly increased with either technique during positioning. Both techniques significantly affected left ventricular function decreasing stroke volume and ejection fraction. In the vertical and rotated position, the ApSD produced a significant decrease from baseline both in stroke volume (DPS: 32.8±18.7 vs ApSD: 55.46±21.7; p =0.02) and in ejection fraction (DPS: 19.3±10.5 vs ApSD: 40.9±24.6; p =0.02). The three-dimensional reconstructions demonstrated significant distortion of the atrioventricular geometry and the mitral valve, which was more pronounced with the DPS. Conclusion: Both techniques produce variable degrees of deformation with associated cardiac dysfunction and haemodynamic instability. Cardiac function is impeded more with an ApSD with the heart elevated and rotated.
ACCESSION #
26488643

 

Related Articles

  • Predictors of ascending aortic dilatation with bicuspid aortic valve: a wide spectrum of disease expression Della Corte, Alessandro; Bancone, Ciro; Quarto, Cesare; Dialetto, Giovanni; Covino, Franco E.; Scardone, Michelangelo; Caianiello, Giuseppe; Cotrufo, Maurizio // European Journal of Cardio-Thoracic Surgery;Mar2007, Vol. 31 Issue 3, p397 

    Abstract: Objective: This study aimed to describe the features and identify the predictors of ascending aorta dilatation in patients with congenital bicuspid aortic valve (BAV). Methods: In 280 adult patients with isolated BAV undergoing echocardiography, multivariate logistic regression models,...

  • Editorial Board.  // Heart, Lung & Circulation;Oct2014, Vol. 23 Issue 10, piii 

    No abstract available.

  • Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery Confirmed by 320-Slice Computed Tomography. Zhu, Jian; Liu, Yong; Zhu, Shui-Bo; Zhang, Yu // Pediatric Cardiology;Jun2013, Vol. 34 Issue 5, p1283 

    Anomalous origin the left coronary artery from the pulmonary artery (ALCAPA) is an extremely rare congenital coronary abnormality that may be difficult to diagnose by echocardiography. Most patients present with a potentially fatal illness leading to sudden cardiac death during infancy. This...

  • A case of a thrombus trapped in a patent foramen ovale. Chandrala, P.; Johnson, K.; Hallani, H. // Heart, Lung & Circulation;2015 Supplement 3, Vol. 24, pS315 

    No abstract available.

  • Utility of perioperative transesophageal echocardiography. Muralidhar, K. // Annals of Cardiac Anaesthesia;2016 Special Issue, Vol. 19, pS2 

    The author reflects on the utility and potential of the Trans-Esophageal Echocardiography (TEE) technique during cardiac surgery. He explains that TEE provides direct and real-time visualization of cardiac structures during surgery and in assessing results of surgical reconstruction or...

  • Intraoperative echocardiography. Oxorn, Donald C. // Heart;Sep2008, Vol. 94 Issue 9, p1236 

    The article discusses a study on the use of intraoperative transoesophageal echocardiography (TOE) and its impact on patient outcome. The study suggests that TOE gives echocardiographer the ability to examine various components of global venticular function. It is concluded that TOE has improved...

  • Anomalous drainage of the inferior caval vein to the left atrium. Sierig, Gabriele; Vondrys, David; Daehnert, Ingo // Cardiology in the Young;Feb2005, Vol. 15 Issue 1, p85 

    We report a girl, aged 117⁄12 years, who presented with cyanosis. Cardiac catheterization showed occlusion of the infrahepatic segment of the inferior caval vein, with drainage of the hepatic veins into the left atrium. Transoesophageal echocardiography revealed an anomalous Eustachian...

  • Transesophageal echocardiography in the intensive care unit. Karski, Jacek M. // Seminars in Cardiothoracic & Vascular Anesthesia;Jun2006, Vol. 10 Issue 2, p162 

    Transesophageal echocardiography provides unique diagnostic capabilities, allowing for a very precise look at the structure and hemodynamics of the human heart. It is minimally invasive and portable, and quickly diagnoses sudden hemodynamic changes in intensive care patients. It provides...

  • Echocardiographic evaluation of right heart function and pulmonary vascular bed. Cacciapuoti, Federico // International Journal of Cardiovascular Imaging;Oct2009, Vol. 25 Issue 7, p689 

    The aim of this review was to describe the different ultrasonic modalities to non-invasively evaluate right cardiac chambers and pulmonary vascular bed function. M-Mode, 2-D, conventional pulsed doppler, tissue doppler imaging (TDI), strain rate imaging (SRI) and 3D echocardiography are...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library