TITLE

Hydrodynamic performance and heat generation by centrifugal pumps

AUTHOR(S)
Ganushchak, Y.; van Marken Lichtenbelt, W.; van der Nagel, T.; de Jong, D. S.
PUB. DATE
November 2006
SOURCE
Perfusion;Nov2006, Vol. 21 Issue 6, p373
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
For over a century, centrifugal pumps (CP) have been used in various applications, from large industrial pumps to flow pumps for aquariums. However, the use of CP as blood pumps has a rather short history. Consequently, the hydraulic performance data for a blood CP are limited. The aim of our investigation was to study the hydraulic performance and the heat generation of three commercially available CP: Bio-Medicus Bio-Pump BP80 (Medtronic), Rotaflow (Jostra Medizintechnik), and DeltaStream™ DP2 (MEDOS Medizintechnik AQ). The study was performed using a circuit primed with a water-glycerin mixture with a dynamic viscosity of 0.00272 pa/s. Pressure-flow curves were obtained by a stepwise stagnation of the pump outlet or inlet. The temperature changes were observed using ThermaCAM SC2000 (Flir Systems). The pumps' performance in close to clinical conditions (‘operating region’) was analysed in this report. The ‘operating region’ in the case of the BP80 is positioned around the pressure-flow curve at a pump speed of 3000 rpm. In the case of the Rotaflow, the ‘operating region’ was between the pump pressure-flow curves at a speed of 3000 and 4000 rpm, and the DP2 was found between 7000 and 8000 rpm. The standard deviation of mean pressure through the pump was used to characterise the stability of the pump. In experiments with outlet stagnation, the BP80 demonstrated high negative association between flow and pressure variability (r=-/0.68, p <0.001). In experiments with the DP2, this association was positive (r=0.68, p < 0.001). All pumps demonstrated significantly higher variability of pressure in experiments with inlet stagnation in comparison to the experiments with outlet stagnation. The rise of relative temperature in the inlet of a pump was closely related to the flow rate. The heating of fluid was more pronounced in the ‘zero-flow’ mode, especially in experiments with inlet stagnation. In summary, (1) the ‘zero-flow’ regime, which is described in the manuals of some commercially-available pumps, is the use of the pump outside the allowable operating region. It is potentially dangerous and should, therefore, never be used in clinical settings. (2) Using centrifugal pumps for kinetic-assisted venous return can only be performed safely when the negative pressure at the inlet of the pump is monitored continuously. The maximum allowable negative pressure has to be defined for each type of pump, and must be based on pump performance.
ACCESSION #
26045023

 

Related Articles

  • Radial blade pump with an active hydrodynamic seal. Rusetskaya, G. // Chemical & Petroleum Engineering;Nov/Dec2005, Vol. 41 Issue 11/12, p596 

    We have studied the design of a pump with an active hydrodynamic seal (PAHS) which is the impeller system of a centrifugal pump, inverted in a system of spiral channels on the outer surface of the impeller. The PAHS ensures reliable sealing of clearance between the impeller and the front cover...

  • Why Your Pump Doesn't Always Do What You Want. Mackay, Ross // Processing (08968659);Jun2010, Vol. 23 Issue 6, p6 

    The article presents an explanation on why centrifugal pumps do not do what is expected of it given the fact that it is only controlled by the system that holds it.

  • Saving energy through pump speed control. Widell, Bruce // Design News;2/20/95, Vol. 51 Issue 4, p80 

    Describes a technology that saves energy through pump speed control. Use of adjustable-frequency drive; Electrical energy operating centrifugal loads in pumps; Elimination of need for throttling and restrictive devices; Contact information.

  • BASIC FACTS.  // Public Works;Spring2012, Vol. 143 Issue 6, p126 

    The article presents information on some basic facts related to centrifugal pumps, including its working, in which sludge enters an impeller and is accelerated in circumferential direction, and different types of centrifugal pumps, including channel impeller, self-priming, and screw impeller.

  • Considerations for Successful Pump Applications. Weis, Frank // WaterWorld;Jan2000, Vol. 16 Issue 1, p44 

    Discusses tip related to buying centrifugal wastewater pumps. Performance and service life; Maintenance requirements; Pump station considerations.

  • Evaluation of prebiotic and probiotic dietary supplementation on growth performance and some blood parameters of Cyprinus carpio Frys. Eleraky, Wafaa; Yahya, M.; Reda, Rasha M.; Eletreby, S. // Egyptian Journal of Aquatic Biology & Fisheries;Jul2014, Vol. 18 Issue 2, p29 

    The objective of this study was to evaluate the effect of prebiotics and probiotics on the growth performance, non-specific immunity and chemical composition of Cyprinus carpio. A total of 250 fry of Cyprinus carpio with an average body weight and length were used in experiments 2.82 ± 0.12g...

  • Blood clotting prediction model using Artificial Neural Networks and Sensor Networks. Lela, Mirtskhulava; Salah, Al-Majeed; Pearce, Gillian; Tamar, Gogoladze; Javakhishvili, Ivane // Computer Science & Telecommunications;2014, Vol. 43 Issue 3, p60 

    The purpose of the given paper is to analyze blood clots (BCs) by using Artificial Neural Network (ANN) using the physical symptoms as the input data. Such a NN provides an analytical alternative to conventional techniques, and allows the user to model BCs. Sensor Data application provides...

  • Increased blood flow in the anterior humeral circumflex artery correlates with night pain in patients with rotator cuff tear. Terabayashi, Nobuo; Watanabe, Tsuneo; Matsumoto, Kazu; Takigami, Iori; Ito, Yoshiki; Fukuta, Masashi; Akiyama, Haruhiko; Shimizu, Katsuji // Journal of Orthopaedic Science;Sep2014, Vol. 19 Issue 5, p744 

    Background: Night pain is a particularly vexing symptom in patients with rotator cuff tear. It disturbs sleep and decreases quality of life, and there is no consensus regarding its etiology. Based on arthroscopic surgical observations of synovitis around the rotator interval or capsule surface...

  • Test-retest repeatability of myocardial blood flow and infarct size using C-acetate micro-PET imaging in mice. Croteau, Etienne; Renaud, Jennifer; McDonald, Matthew; Klein, Ran; DaSilva, Jean; Beanlands, Rob; deKemp, Robert // European Journal of Nuclear Medicine & Molecular Imaging;Sep2015, Vol. 42 Issue 10, p1589 

    Purpose: Global and regional responses of absolute myocardial blood flow index (iMBF) are used as surrogate markers to assess response to therapies in coronary artery disease. In this study, we assessed the test-retest repeatability of iMBF imaging, and the accuracy of infarct sizing in mice...

Share

Read the Article

Courtesy of NEW JERSEY STATE LIBRARY

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics