TITLE

Introducing wet aerosols into the static high sensitivity ICP (SHIP)

AUTHOR(S)
Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang
PUB. DATE
August 2007
SOURCE
Analytical & Bioanalytical Chemistry;Aug2007, Vol. 388 Issue 8, p1605
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3–0.5 L min−1) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min−1 for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min−1 for the plasma gas and 0.44 L min−1 for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97–103% for 13 elements, measured simultaneously. [Figure not available: see fulltext.]
ACCESSION #
25905073

 

Related Articles

  • Evolution of Nonequilibrium Aerosol Parameters in Crown-Streamer Discharge Plasma. Kozyrev, A. V.; Sitnikov, A. G.; Sochugov, N. S. // Technical Physics Letters;Jun2005, Vol. 31 Issue 6, p475 

    Nonstationary parameters of an aerosol formed from unsaturated vapors of styrene and n-hexane in a pulsed crown-streamer discharge in air or argon at atmospheric pressure have been studied. In the initial stage of aerosol formation, the concentration of aerosol particles was on the order of...

  • 7Be and 210Pb concentrations in air in Málaga (Spain). Dueñas, C.; Fernández, M. C.; Carretero, J.; Liger, E.; Cañete, S. // Journal of Radioanalytical & Nuclear Chemistry;Aug2003, Vol. 257 Issue 2, p249 

    Measurements of 7Be and 210Pb in atmospheric air (1 m above the ground) have been carried out each week over one and a half year period. The method used to determine 7Be and 210Pb activities is based on the total amount of radioactive aerosols filtered from the air. The activities of 7Be and...

  • The hygroscopicity parameter (κ) of ambient organic aerosol at a field site subject to biogenic and anthropogenic influences: Relationship to degree of aerosol oxidation. Chang, R. Y.-W.; Slowik, J. G.; Shantz, N. C.; Vlasenko, A.; Liggio, J.; Sjostedt, S. J.; Leaitch, W. R.; Abbatt, J. P. D. // Atmospheric Chemistry & Physics Discussions;2009, Vol. 9 Issue 6, p25323 

    Cloud condensation nuclei (CCN) concentrations were measured at a rural site in Ontario, Canada during the spring of 2007. The CCN concentrations were compared to values predicted from the aerosol chemical composition and size distribution using κ-Köhler theory. The hygroscopicity of the...

  • Ambient aerosols and human health: working towards a combined analytical and toxicological approach. Zimmermann, Ralf // Analytical & Bioanalytical Chemistry;Jan2012, Vol. 401 Issue 10, p3041 

    An introduction is presented in which the author discussed various reports published within the issue, including the application of new mass spectrometric tools, the characterization of the organic content of aerosols, and on-line aerosol mass spectrometric techniques.

  • nebulizer.  // Taber's Cyclopedic Medical Dictionary (2009);2009, Issue 21, p1547 

    A definition of the term "nebulizer," which refers to an apparatus used for producing a fine spray or mist, is presented.

  • Evaluation of several pneumatic micronebulizers with different designs for use in ICP-AES and ICP-MS. Future directions for further improvement. Maestre, S.E.; Todoli, J.L.; Mermet, J.M. // Analytical & Bioanalytical Chemistry;Jul2004, Vol. 379 Issue 5/6, p888 

    This paper reports characterization of the behavior of five pneumatic micronebulizers based on slightly different designs in inductively coupled plasma atomic-emission spectrometry and mass spectrometry (ICP-AES and ICP-MS). Two nebulizers were used as reference nebulizers, a high-efficiency...

  • Spectrochemical determination of trace uranium by an argon-stabilized U-shaped DC arc. Novović, I.; Nikolić, V.; Marković, D. // Journal of Analytical Chemistry;Sep2007, Vol. 62 Issue 9, p837 

    An argon-stabilized U-shaped DC arc with the system for aerosol introduction was used for uranium determination. High uranium toxicity suggests the necessity of developing as sensitive methods as possible for U detection in various natural samples and complex matrices. By optimizing the...

  • Size Distribution of Inorganic Species and Their Inhaled Dose in a Detergent Industrial Workplace. Karanasiou, A.; Eleftheriadis, K.; Vratolis, S.; Zarbas, P.; Mihalopoulos, N.; Mitsakou, C.; Housiadas, C.; Lazaridis, M.; Ondracek, J.; Dzumbova, L. // Water, Air & Soil Pollution: Focus;Jan2008, Vol. 8 Issue 1, p71 

    Aerosol particles in the workplace of a detergent industry were sampled during July 2005 by a Berner low-pressure impactor. The samples were analyzed by atomic absorption spectrometry and ion chromatography in order to determine the size distribution of metallic elements and water-soluble...

  • Sensitive Determination of Lead by Flame Atomic Absorption Spectrometry Improved with Branched Capillary as Hydride Generator and Without Phase Separation. Qing Tan; Peng Wu; Li Wu; Xiandeng Hou // Microchimica Acta;Nov2006, Vol. 155 Issue 3/4, p441 

    The sensitivity of traditional flame atomic absorption spectrometry (FAAS) is low for the determination of lead. Therefore, a simple branched capillary was used for hydride generation with air-acetylene FAAS determination of lead in geochemical samples and paint. Using a Y-shaped connector, the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics