TITLE

WHAT Is TVSS TECHNOLOGY?

AUTHOR(S)
Hemphill, Matt
PUB. DATE
July 2007
SOURCE
Energy & Power Management;Jul2007, Vol. 32 Issue 7, p16
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
The article offers information on transient voltage surge suppression (TVSS) that is responsible for starting facility fires and for compromising human safety conditions. It stated that UL 1449 Safety Standard for Transient Voltage Surge Suppressors second edition comes as a result of the industry's awareness of catastrophic TVSS failures. Moreover, the TVSS technology continue to rely on thermal and overcurrent fusing to comply with the revised UL 1449 requirements.
ACCESSION #
25843648

 

Related Articles

  • CHAPTER 13: STABILITY OF LOAD NODE OPERATION AT LARGE DISTURBANCES.  // Advanced Engineering Forum;2016, Vol. 15, p327 

    No abstract available.

  • Generalization of Transient Stability Solution Using Neural Network Theory. ikenono, Katsumi; Iwamoto, Shinichi // Electrical Engineering in Japan;6/1/1992, Vol. 112 Issue 3, p72 

    This paper presents a generalized online transient stability solution technique using the backpropagation method of the neural network theory. The proposed solution technique can be used for general generator models, including controllers such as AVRs and governors, that have been difficult for...

  • Excitation Control under Early Valve Actuation of Turbine. Kakimoto, Naoto; Yoneda, Tutomu; Hayashi, Muneaki; Sugihara, Hiroaki // Electrical Engineering in Japan;1991, Vol. 111 Issue 4, p77 

    Focuses on the excitation control under early valve actuation of turbine in Japan. Usage of early valve control technique to improve the transient stability; Suppression of the rotor swing quickly by controlling the excitation using a power system stabilizer; Discussion of the realization of...

  • Fault location in power transmission lines using adaptive lifting scheme. Ji, Z.; Li, H.H.; Li, Q.; Wu, Q.H. // Electronics Letters;3/31/2005, Vol. 41 Issue 7, p440 

    A novel adaptive lifting scheme is proposed to effectively extract features of fault-generated high-frequency transient waveforms in power transmission lines. The accurate and fast fault location is achieved.

  • In Search of Transients. Turkel, Stan // EC&M Electrical Construction & Maintenance;Nov2000, Vol. 99 Issue 11, p16 

    Comments on strategies for examining sources of electrical transients to evaluate electric power system stability. Techniques for finding internal voltage spikes; Approaches for troubleshooting. INSET: The Case of the Bad UPS.

  • Analysis of one-line ground fault surge on simulated overhead distribution line. Kikuchi, Tatsuo; Yoshimi, Masashi; Hikosaka, Tomoyuki; Matsumoto, Toshio // Electrical Engineering in Japan;01/15/1997, Vol. 118 Issue 1, p52 

    One-line fault location techniques of intermittent ground fault points on nongrounded distribution lines are necessary to supply steady electric power for customers. This paper proposes a novel method that uses frequency spectra of transient waveforms at a sending end when an intermittent ground...

  • Investigation of VFT surges propagated into transformer and overvoltages applied to winding. Ishikawa, Yasuhisa; Iwai, Akihiko; Nishiwaki, Susumu; Koshizuka, Tadashi; Teranishi, Tsuneharu; Uehara, Kyouichi // Electrical Engineering in Japan;1/30/2004, Vol. 146 Issue 2, p20 

    Investigations were conducted on the VFT (Very Fast Transient) surges that propagate into a 500-kV transformer. The disconnector restriking surge and ground fault surged were discussed. It was regarded that a large part of the surge voltage was applied just at the entrance of the transformer...

  • Data line surge protection: Fact vs. fiction. Fowler, Jim // Communications News;Mar1998, Vol. 35 Issue 3, p44 

    Discusses several myths about data line surges and surge protection. Whether data line surges pose no major threat to computing equipment; Whether equipment is safe from data line surges if the building location is not lightning-prone; Whether equipment is safe from data line surges if it is...

  • Design of TCSC Controller for Improvement of Transient Stability of a Power System. Mandadi, P. Nagaraju; Dhanvanthri, K. // International Review on Modelling & Simulations;Dec2011, Vol. 4 Issue 6, p3175 

    FACTS controllers , because of their fast response, improves the Transient Stability limit of a power System by giving away the excess energy gained by the generators in the event of disturbances due to faults. Thyristor controlled Series Compensator (TCSC) is an important device in FACTS family...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.