TITLE

Surgical Treatment of Intra-Articular Fractures of the Distal Part of the Humerus

AUTHOR(S)
Doornberg, Job N.; Van Duijn, Pleun J.; Linzel, Durk; Ring, David C.; Zurakowski, David; Marti, Rene K.; Kloen, Peter
PUB. DATE
July 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Jul2007, Vol. 89-A Issue 7, p1524
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: The short-term results of open reduction and internal fixation of intra-articular distal humeral fractures are good to excellent in approximately 75% of patients, but the long-term results have been less well studied. This investigation addressed the long-term clinical and radiographic results of surgical treatment of intra-articular distal humeral fractures (A0 Type C) as assessed with use of standardized outcome measures. Methods: Thirty patients were evaluated at an average of nineteen years (range, twelve to thirty years) after open reduction and internal fixation of a fracture of the distal part of the humerus to assess the range of elbow motion and the functional outcome. Twenty patients had an olecranon osteotomy, and all had fixation with plates and/or screws and/or Kirschner wires. No ulnar nerve was transposed. Results: Excluding one elbow salvaged with an arthrodesis and counted as a poor result, the average final flexion arc was 106° and the average pronation-supination arc was 165°. The average American Shoulder and Elbow Surgeons (ASES) score was 96 points, with an average satisfaction score of 8.8 points on a 0 to 10-point visual analog scale. The average Disabilities of the Arm, Shoulder and Hand (DASH) score was 7 points, and the average Mayo Elbow Performance Index (MEPI) score was 91 points, Including the patient with the arthrodesis, the final categorical ratings were nineteen excellent results, seven good results, one fair result, and three poor results. The presence of arthrosis did not appear to correlate with pain or predict disability or function. Subsequent procedures were performed in twelve patients (40%). Conclusions: The long-term results of open reduction and internal fixation of AO-Type-C fractures of the distal part of the humerus are similar to those reported in the short term, suggesting that the results are durable. Functional ratings and perceived disability were predicated more on pain than on functional impairment and did not correlate with radiographic signs of arthrosis. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
25781164

 

Related Articles

  • Arthroscopic assisted removal of screws from proximal humeral locking plates. Dattani, Rupen; Patel, Vipul R. // International Journal of Shoulder Surgery;Jul-Sep2013, Vol. 7 Issue 3, p125 

    A letter to the editor is presented which describes a method for removal or exchange of prominent screws from proximal humeral locking plates during osteosynthesis.

  • OPEN REDUCTION AND INTERNAL FIXATION OF HUMERAL NONUNIONS. Rubel, Iván F.; Kloen, Peter; Campbell, Deirdre; Schwartz, Mark; Liew, Alan; Myers, Elizabeth; Helfet, David L. // Journal of Bone & Joint Surgery, American Volume;Aug2002, Vol. 84-A Issue 8, p1315 

    Background: Several studies have compared different methods for fixation of the midpart of the humeral shaft, but there are only scattered data regarding which type of plate construct provides the best fixation for humeral nonunion. The objectives of this study were (1) to obtain objective data...

  • Open Reduction and Internal Fixation of Three and Four-Part Fractures of the Proximal Part of the Humerus. Wijgman, A.J.; Roolker, W.; Patt, T.W.; Raaymakers, E.L.F.B.; Marti, R.K. // Journal of Bone & Joint Surgery, American Volume;Nov2002, Vol. 84-A Issue 11, p1919 

    Background: Controversy persists concerning the preferred treatment of displaced fractures of the proximal part of the humerus. The present study was undertaken to evaluate the results of open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus...

  • OPEN REDUCTION AND INTERNAL FIXATION OF DELAYED UNIONS AND NONUNIONS OF FRACTURES OF THE DISTAL PART OF THE HUMERUS. Helfet, David L.; Kloen, Peter; Anand, Neel; Rosen, Howard S. // Journal of Bone & Joint Surgery, American Volume;Jan2003, Vol. 85-A Issue 1, p33 

    Background: The purpose of the present retrospective study was to evaluate the results of open reduction and internal fixation of delayed unions and nonunions of fractures of the distal part of the humerus. Methods: Between 1976 and 2001, fifty-two patients with a delayed union (thirteen...

  • Minimally Invasive Anterior Plate Osteosynthesis in Humeral Shaft Fractures. Schwarz, Nikolaus; Windisch, Manfred; Mayr, Birgit // European Journal of Trauma & Emergency Surgery;Jun2009, Vol. 35 Issue 3, p271 

    Twelve patients with shaft fractures of the humerus were treated with percutaneous anterior plate osteosynthesis using a deltoid-pectoral respectively brachialis splitting approach without exposure of the radial nerve. The implants used were PHILOS plates, locking compression plates 3.5 and 4.5,...

  • Bone quality measured by the radiogrammetric parameter “cortical index” and reoperations after locking plate osteosynthesis in patients sustaining proximal humerus fractures. Hepp, Pierre; Theopold, Jan; Osterhoff, Georg; Marquass, Bastian; Voigt, Christine; Josten, Christoph // Archives of Orthopaedic & Trauma Surgery;Sep2009, Vol. 129 Issue 9, p1251 

    To analyse the radiogrammetric parameter “cortical index” (CI) and its predictive value for proximal humerus fractures. Furthermore, to investigate the reoperations and the cause of reoperations after locking plate osteosynthesis of displaced proximal humerus fractures. 113...

  • Pediatric Distal Humeral Fractures and Complications of Treatment in Finland. Vallila, Noora; Sommarhem, Antti; Paavola, Mika; Nietosvaara, Yrjänä // Journal of Bone & Joint Surgery, American Volume;3/18/2015, Vol. 97 Issue 6, p494 

    Background: The distal part of the humerus is the second most common fracture location in children. Complications are more common than with other pediatric fractures and are mostly related to inappropriate diagnosis and treatment. Methods: On the basis of data from 1990 through 2010 in the...

  • A Look at Triple Arthrodesis Joint Fusion without Rigid Internal Fixation. Marin, Luis E.; Auger, Federico A.; Balkaran, Joanne N.; Heath, Liliana M.; Ojeda, Giselle // Surgical Science;May2012, Vol. 3 Issue 5, p261 

    Triple arthrodesis is an invasive procedure that involves denuding and fusion of three foot joints; Talocalcaneal (T-C), Talonavicular (T-N) and Calcaneocuboid (C-C). Traditionally, with external fixation triple arthrodesis has been performed without corresponding internal fixation. The purpose...

  • Comparing biomechanical investigations about different wiring techniques of finger joint arthrodesis. Mittelmeier, W.; Lehner, S.; Gollwitzer, H.; Hauschild, M.; Werber, K.; Steinhauser, E. // Archives of Orthopaedic & Trauma Surgery;Apr2005, Vol. 125 Issue 3, p145 

    Introduction Multiple operative techniques are currently used for finger arthrodesis in clinical practice. The present study was designed to compare the biomechanical characteristics of typical arthrodesis techniques used in daily practice. Material and methods Osteosynthesis techniques...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics