TITLE

Indoor air quality and the risk of lower respiratory tract infections in young Canadian Inuit children

AUTHOR(S)
Kovesi, Thomas; Gilbert, Nicolas L.; Stocco, Corinne; Fugler, Don; Dales, Robert E.; Guay, Mireille; Miller, J. David
PUB. DATE
July 2007
SOURCE
CMAJ: Canadian Medical Association Journal;7/17/2007, Vol. 177 Issue 2, p155
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Inuit infants have the highest reported rate of hospital admissions because of lower respiratory tract infections in the world. We evaluated the prevalence of reduced ventilation in houses in Nunavut, Canada, and whether this was associated with an increased risk of these infections among young Inuit children. Methods: We measured ventilation using indoor monitors in 49 homes of Inuit children less than 5 years of age in Qikiqtaaluk (Baffin) Region, Nunavut. We identified the occurrence of lower respiratory trace infections using a standardized questionnaire. Associations between ventilation measures and lower respiratory tract infection were evaluated using multiple logistic regression models. Results: The mean number of occupants per house was 6.1 people. The mean ventilation rate per person was 5.6 L/s (standard deviation [SD] 3.7); 80% (37/46) of the houses had ventilation rates below the recommended rate of 7.5 L/s per person. The mean indoor carbon dioxide (CO2) concentration of 1358 (SD 531) ppm was higher than the recommended target level of 1000 ppm. Smokers were present in 46 homes (94%). Of the 49 children, 27 (55%) had a reported history of lower respiratory tract infection. Reported respiratory infection was significantly associated with mean CO2 levels (odds ratio [OR] 2.85 per 500-ppm increase in mean indoor CO2, 95% confidence interval [CI] 1.23–6.59) and occupancy (OR 1.81 for each additional occupant, 95% CI 1.14-2.86). Interpretation: Reduced ventilation and crowding may contribute to the observed excess of lower respiratory tract infection among young Inuit children. The benefits of measures to reduce indoor smoking and occupancy rates and to increase ventilation should be studied.
ACCESSION #
25627785

 

Related Articles

  • Respiratory tract infections in Inuit children: "Set thine house in order". Orr, Pamela H. // CMAJ: Canadian Medical Association Journal;7/17/2007, Vol. 177 Issue 2, p167 

    The author comments on a study of T. Kovesi and colleagues about the relation between environmental indoor air quality and lower respiratory tract infections in Inuit children in Canada, which is published within the issue. In the study researchers indicates that Inuit children experience high...

  • Indoor air quality and the risk of lower respiratory tract infections in young Canadian Inuit children. Kovesi, Thomas; Gilbert, Nicolas L.; Stocco, Corinne; Fugler, Don; Dales, Robert E.; Guay, Mireille; Miller, David // CMAJ: Canadian Medical Association Journal Supplement;7/17/2007, Vol. 177 Issue 2, p155 

    Background: Inuit infants have the highest reported rate of hospital admissions because of lower respiratory tract infections in the world. We evaluated the prevalence of reduced ventilation in houses in Nunavut, Canada, and whether this was associated with an increased risk of these infections...

  • Respiratory tract infections in Inuit children: "Set thine house in order.". Orr, Pamela H. // CMAJ: Canadian Medical Association Journal Supplement;7/17/2007, Vol. 177 Issue 2, p167 

    The article focuses on research on the relationship between environmental indoor air quality and lower respiratory tract infection in Inuit children. The researchers found a significant association between reported lower respiratory tract infection in the youngest child of the household and both...

  • Breaking the mould. German, Amy // Nation (1206-2642);5/3/2013, Vol. 20 Issue 13, p21 

    The article discusses how the occurrence of moulds and fungi can worsen the air quality within homes and buildings in Canada, and thus cause a variety of respiratory infections and other health problems among a building's occupants. Dr. Elizabeth Robinson from the Cree Board of Health and Social...

  • AT A GLANCE.  // Consulting-Specifying Engineer;Jan2009, Vol. 45 Issue 1, p50 

    A photograph is presented depicting SEMCO Inc.'s Pinnacle Primary Ventilation and Energy Recovery System.

  • Adding More Fan Power. Beville, Rory S. // ASHRAE Journal;Aug2014, Vol. 56 Issue 8, p10 

    A letter to the editor is presented in response to the article "Adding More Fan Power Can Be a Good Thing," by Ronnie Moffitt that was published in the May 2014 issue.

  • Adding More Fan Power. Moffitt, Ronnie // ASHRAE Journal;Aug2014, Vol. 56 Issue 8, p10 

    A response from the author of the article "Adding More Fan Power Can Be a Good Thing" that was published in the May 2014 issue is presented.

  • IMPROVE INDOOR AIR.  // Athens News;9/10/2012, p19 

    The article provides several steps on how to improve the quality of indoor air in the U.S. which include opening the windows, changing the filters on home heating, and avoiding the use of toxic cleaning products.

  • BEAMA launches ventilation campaign.  // Heating & Ventilating Review;Oct2014, Vol. 53 Issue 12, p8 

    The article reports the launching by the British Electrotechnical and Allied Manufacturers' Association (BEAMA) as of October 2014 of its 'Indoor Air Revolution' campaign to increase consumer and industry awareness on the importance of sufficient ventilation on health.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.