TITLE

Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study

AUTHOR(S)
Haaverstad, Rune; Vitale, Nicola; Karevold, Asbjørn; Cappabianca, Giangiuseppe; Tromsdal, Arve; Olsen, Peter Skov; Köber, Lars; Ihlen, Halfdan; Rein, Kjell Arne; Svennevig, Jan L.
PUB. DATE
April 2007
SOURCE
Heart;Apr2007, Vol. 93 Issue 4, p500
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Objective: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. Methods: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received an aortic advantage valve prosthesis. Complete cumulative follow-up was 242.7 patient-years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. Results: 30 day mortality was 2.4% (n = 4). Kaplan-Meier estimates of freedom from complications and linearised rates were as follows: 96.9 (1.6)% survival; 94.7 (1.3)% (2.06 patients/year) thrombo-embolism; 99.4 (0.6)% (0.4 patients/year) bleeding; 98.8 (0.9)% (0.8 patients/year) non-structural valve dysfunction; 98.8 (0.9)% (0.8 patients/year) reoperation. Valvular mean pressure gradients ranged from 16 (3) mm Hg for size 19 to 7 (2) mm Hg for size 27 and the corresponding effective orifice areas ranged from 1.2 (0.25) to 3.2 (0.66) cm². In all, left ventricular mass significantly decreased (p<0.001) and fractional shortening increased (p<0.001) from postoperative to 1 year echocardiography. Conclusions: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use.
ACCESSION #
25570519

 

Related Articles

  • Early clinical and haemodynamic results after aortic valve replacement with the Freedom SOLO bioprosthesis (experience of Italian multicenter study). Repossini, Alberto; Rambaldini, Manfredo; Lucchetti, Vincenzo; Da Col, Uberto; Cesari, Francesco; Mignosa, Carmelo; Picano, Eugenio; Glauber, Mattia // European Journal of Cardio-Thoracic Surgery;May2012, Vol. 41 Issue 5, p1104 

    OBJECTIVES The present study investigates early clinical and haemodynamic results with the Freedom SOLO bioprosthesis (FSB) for aortic valve replacement (AVR) in eight Italian institutions. METHODS From 2004 to 2008, a total of 229 patients [139 females (60.7%); mean age 74 ± 8 years, left...

  • PREVAIL TRANSAPICAL: multicentre trial of transcatheter aortic valve implantation using the newly designed bioprosthesis (SAPIEN-XT) and delivery system (ASCENDRA-II)†. Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf // European Journal of Cardio-Thoracic Surgery;Aug2012, Vol. 42 Issue 2, p278 

    OBJECTIVES Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. METHODS A total of 150 patients (age: 81.6 ± 5.8 years; 40.7%...

  • Bioprosthetic Valves for Transcatheter Aortic Valve Replacement. Barbanti, Marco; Capodanno, Davide; Tamburino, Corrado // JAMA: Journal of the American Medical Association;8/27/2014, Vol. 312 Issue 8, p843 

    A letter to the editor is presented in response to the article "CHOICE investigators. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial," by M. Abdel-Wahab and colleagues.

  • Bioprosthetic Valves for Transcatheter Aortic Valve Replacement. Reardon, Michael J. // JAMA: Journal of the American Medical Association;8/27/2014, Vol. 312 Issue 8, p844 

    A letter to the editor is presented in response to the article "CHOICE investigators. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial," by M. Abdel-Wahab and colleagues.

  • Bioprosthetic Valves for Transcatheter Aortic Valve Replacement. Abdel-Wahab, Mohamed; Mehilli, Julinda; Richardt, Gert // JAMA: Journal of the American Medical Association;8/27/2014, Vol. 312 Issue 8, p845 

    A response from authors of the article "CHOICE investigators. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial," is presented.

  • Is the threshold for postoperative prosthesis-patient mismatch the same for all prostheses? Okamura, Homare; Yamaguchi, Atsushi; Morita, Hideki; Naito, Kazuhiro; Yuri, Koichi; Adachi, Hideo // Surgery Today;Aug2013, Vol. 43 Issue 8, p871 

    Purpose: The effective orifice area index (EOAI) is used to define the prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR). However, few studies have so far evaluated whether the cutoff value for PPM varies across prostheses. This study assessed the hemodynamics in patients...

  • Infective endocarditis in transcatheter aortic valve implantation. Seok Koh, Yoon; Hyoung Moon, Mi; Hyun Jo, Keon; Wook Kim, Hwan // European Journal of Cardio-Thoracic Surgery;Mar2014, Vol. 45 Issue 3, p582 

    Photographs of a transoesophageal echocardiographic evaluation showing an infected prosthetic valve in the transcatheter aortic valve implantation (TAVI) of an 85-year old male patient are presented.

  • AORTIC VALVE REPLACEMENT; RELATION OF AORTIC ANNULUS MEASURED BY ECHOCARDIOGRAPHY AND PROSTHESIS SIZE REQUIRED. Hussain, Ghulam; Ahmad, Naseem; Ahmad, Sohail; Raza Baig, Mirza Ahmad; Zaheer, Sara // Professional Medical Journal;2015, Vol. 22 Issue 12, p1565 

    Objectives: To determine the preoperative prosthesis size using echocardiography in patients undergoing aortic valve replacement. Study Design: Prospective observational study. Setting: Ch. Pervaiz Elahi Institute of Cardiology (CPEIC) Multan. Period: January 2013 to October 2014. Methods: (100...

  • Aortic valve stenosis: perioperative anaesthetic implications of surgical replacement and minimally invasive interventions. Chacko, Matthew; Weinberg, Laurence // Continuing Education in Anaesthesia, Critical Care & Pain;Dec2012, Vol. 12 Issue 6, p295 

    The article discusses aortic valve stenosis. Surgical aortic valve replacement (AVR) is the gold standard intervention for improving life expectancy and quality. The main investigation in the diagnosis and assessment of AS is echocardiography. It offers general principles for aortic valve...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library