Oxygenator thrombosis: an international phenomenon

AUTHOR(S)
Schaadt, J.
PUB. DATE
November 1999
SOURCE
Perfusion;1999, Vol. 14 Issue 6, p425
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Oxygenator thrombosis, despite adequate anticoagulation, has become a recent concern amongst perfusionists worldwide. The phenomenon is characterized by a transient increase in oxygenator inlet pressure of up to 900 mmHg about 10-15 min after the institution of cardiopulmonary bypass (CPB). Depending on the size and location of the thrombus, shunting may occur that compromises gas transfer to the extent where oxygenator change-out is necessary. This article presents various case reports and publications, both domestic and international, detailing this phenomenon. Research hypothesizes that it is the activation of platelets that subsequently may cause the deposition of fibrin, yielding thrombus formation; however, the primary etiology of this phenomenon remains unknown. Possible catalysts include bypass techniques, equipment selection, pharmacological agents, prime and the patient. This paper will review all of the above with an emphasis on the often overlooked factor - the patient, as there are certain variables in patient hematology that provoke a hypercoagulable state leading to thrombosis, including blood type, genetics, age, disease state, gender and heparin.
ACCESSION #
2539719

 

Related Articles

  • The relative safety of an oxygenator. Svenmarker, S.; Haggmark, S.; Jansson, E.; Lindholm, R.; Appelblad, M.; Aberg, T. // Perfusion;1997, Vol. 12 Issue 5, p289 

    Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions. A general safety index (SI) was defined as the number of recorded...

  • Editorial. Taylor, K. // Perfusion;1998, Vol. 13 Issue 3, p155 

    Editorial. Discusses on the ability of membrane oxygenators to handle and remove air. Quantification and localization of the air removal characteristics of membrane oxygenators; Analysis on the design and manufacture of cardiopulmonary bypass circuit components for neonatal and pediatric...

  • The incidence and cause of emergency oxygenator changeovers. Fisher, A.R. // Perfusion;1999, Vol. 14 Issue 3, p207 

    Emergency oxygenator changeover presents as an important potential hazard during cardiopulmonary bypass. In order to assess the frequency and possible causes of this event a retrospective survey was conducted of cardiothoracic units in the UK and Ireland. The survey was sent to these units in...

  • Cryofibrination: did it really happen? Luckraz, H.; Boolauky, D.; Mohangee, A. // Perfusion;Jan2001, Vol. 16 Issue 1, p83 

    Cryofibrin precipitation is a phenomenon which has only recently been described, although it might have been present since the advent of membraneoxygenators for cardiopulmonary bypass procedures. The deposition of the cold-reactive protein, cryofibrin, causes progressive occlusion of the...

  • Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure. Groom, R. C.; Forest, R. J.; Cormack, J. E.; Niimi, K. S.; Morton, J. // Perfusion;Nov2002, Vol. 17 Issue 6, p447 

    We present here a technique to replace a failed oxygenator by inserting a second oxygenator in parallel (PRONTO) within the cardiopulmonary bypass (CPB) circuit. Oxygenator failure is a potential hazard that may result in patient injury or death. Although failures are rare, safety surveys...

  • Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators. de Somer, F.; Dierickx, P.; Dujardin, D.; Verdonck, P.; Nooten, G.V. // Perfusion;1998, Vol. 13 Issue 3, p157 

    At present, air handling of a membrane oxygenator is generally studied by using an ultrasonic sound bubble counter. However, this is not a quantitative method and it does not give any information on where air was entrapped in the oxygenator and if it eventually was removed through the membrane...

  • A clinical evaluation of platelet function, haemolysis and oxygen transfer during cardiopulmonary bypass comparing the Quantum HF-6700 to the HF-5700 hollow fibre membrane oxygenator. Chukwuemeka, AO; Turtle, M. R. J.; Trivedi, U. H.; Venn, G. E.; Chambers, D. J. // Perfusion;Oct2000, Vol. 15 Issue 6, p479 

    The continued improvement of oxygenators is an important aspect of patient safety during cardiopulmonary bypass (CPB). The purpose of this study was to compare the Bard William Harvey HF-5700 oxygenator to the upgraded Bard Quantum HF-6700, which has recently been introduced into clinical...

  • Massive Intravascular Thrombosis and Thromboembolism after Cardiopulmonary Bypass. Ramsey, Michael A. E.; Marcel, Randy J.; Capeheart, John; Cheung, Edson H.; Ring, W. Steves // Internet Journal of Thoracic & Cardiovascular Surgery;2002, Vol. 5 Issue 2, p83 

    This report describes two patients who underwent cardiac surgery utilizing cardiopulmonary bypass (CPB). Both patients were fully heparinized during the bypass period; however, both of them developed massive intravascular thrombosis and thromboembolism after initiation of heparin reversal with...

  • Methylene Blue Administration Mimics an Oxygenator Failure during Cardiopulmonary Bypass. Saczkowski, Richard; Smith, Michael // Internet Journal of Thoracic & Cardiovascular Surgery;2009, Vol. 13 Issue 1, p2 

    An oxygenator failure during cardiopulmonary bypass is an emergency. The entire cardiac surgical team requires a comprehensive and methodical approach to troubleshoot the possible cause. We report that the bolus administration of methylene blue during cardiopulmonary bypass will induce a...