TITLE

Analytical Model to Predict Punching Shear Strength of FRP-Reinforced Concrete Flat Slabs

AUTHOR(S)
Theodorakopoulos, Dimitrios D.; Swamy, Narayan
PUB. DATE
May 2007
SOURCE
ACI Structural Journal;May/Jun2007, Vol. 104 Issue 3, p257
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The use of fiber-reinforced polymer (FRP) reinforcement in practice, especially where the corrosion of steel bars is a concern, is very much hampered by the absence of a rational theoretical method of analysis to predict the ultimate strength of structural elements, especially flat slabs and bridge decks, made with FRP-reinforced concrete. This study aims to evaluate the punching shear capacity of internally FRP-reinforced slab-column connections without shear reinforcement. The method is based on a simple analytical model developed by the authors for concrete slabs reinforced with conventional steel. The effects of the FRP elastic modulus, ultimate tensile strength, and bond characteristics, which are sufficiently different from those of steel, are incorporated in the existing model. The predictions of the proposed model for FRP-reinforced slabs are then compared with test results obtained from 28 slabs recently reported in the literature. The comparisons show excellent agreement between the predicted and experimental values. It is concluded that the proposed predictive equation presented in this study provides a convenient and reliable framework for the punching strength analysis of slabs reinforced with FRP bars or grids.
ACCESSION #
25375996

 

Related Articles

  • Punching of Two-Way Concrete Slabs with Fiber-Reinforced Polymer Reinforcing Bars or Grids. Ospina, Carlos E.; Alexander, Scott D. B.; Cheng, J. J. Roger // ACI Structural Journal;Sep2003, Vol. 100 Issue 5, p589 

    Examines the punching shear behavior of two-way concrete slabs with interior column-supported fiber-reinforced polymer (FRP) subjected to concentric gravity loading. Validity of proposed shear design recommendations for slabs with internal FRP reinforcement; Factor contributing to punching...

  • Flat Slabs at Slab-Column Connection: Nonlinear Finite Element Modelling and Punching Shear Capacity Design Criterion. Xiao, R. Y.; Chin, C. S. // Advances in Structural Engineering;Oct2007, Vol. 10 Issue 5, p567 

    Nonlinear finite element analysis has become very useful in modelling complicated structural systems and their behaviour. In this paper, an attempt has been made to utilize a tension softening material (TSM) model to simulate the full precracking and post-cracking response of fibre reinforced...

  • Punching Shear Response of High-Performance Fiber-Reinforced Cementitious Composite Slabs. Theodorakopoulos, Dimitrios; Swamy, Narayan // ACI Structural Journal;Jan/Feb2008, Vol. 105 Issue 1, p113 

    The article discusses a study entitled "Punching Shear Response of High-Performance Fiber-Reinforced Cementitious Composite Slabs," by Antoine Naaman, Visit Likhitruangsilp and Gustavo Parra-Montesinos. The discusser believes that the authors have presented an interesting work and provided...

  • Punching shear tests of normal- and high-strength concrete flat plates. Ozden, Sevket; Ersoy, Ugur; Ozturan, Turan // Canadian Journal of Civil Engineering;Nov2006, Vol. 33 Issue 11, p1389 

    Experimental research was conducted to investigate the punching shear performance of flat plates. A large number of slab specimens of normal- and high-strength concrete were tested under concentric and eccentric loads. The effects of flexural reinforcement and the use of steel fiber...

  • Shear in Steel Fiber-Reinforced Concrete Slabs Reinforced with High-Strength Steel. Talboys, Laura N.; Lubell, Adam S. // ACI Structural Journal;Nov/Dec2014, Vol. 111 Issue 6, p1431 

    The combined use of steel fiber-reinforced concrete (SFRC) and high-performance deformed steel reinforcing bars in structural members offers the potential for enhanced strength and durability with extended service life compared to traditional construction materials. While the structural...

  • Compression Field Modeling of Fiber-Reinforced Concrete Members Under Shear Loading. Minelli, Fausto; Vecehio, Frank J. // ACI Structural Journal;Mar/Apr2006, Vol. 103 Issue 2, p244 

    Several laboratory experiments have demonstrated the effectiveness of steel fibers in substituting the minimum code-required shear reinforcement in beams, particularly in precast high-performance concrete structures. Despite the large number of experimental results available, only a few...

  • CALCULATION MODEL FOR STEEL FIBRE REINFORCED CONCRETE PUNCHING ZONES OF BRIDGE SUPERSTRUCTURE AND FOUNDATION SLABS. Marčiukaitis, Gediminas; Šalna, Remigijus; Jonaitis, Bronius; Valivonis, Juozas // Baltic Journal of Road & Bridge Engineering (Baltic Journal of R;Sep2011, Vol. 6 Issue 3, p193 

    The usage of steel fibre reinforced concrete in monolithic joins is well known as a good alternative of additional reinforcement because of chaotic distribution of steel fibres in complex stress ant strain state. Unfortunately, the analysis of well known design codes and different models even in...

  • Punching Shear Strength of Reinforced Concrete Slabs Strengthened with Glass Fiber-Reinforced Polymer Laminates. Cheng-Chih Chen; Chung-Yan Li // ACI Structural Journal;Jul/Aug2005, Vol. 102 Issue 4, p535 

    This study investigates the punching shear strength and failure behavior of reinforced concrete slabs strengthened with glass fiber-reinforced polymer (GFRP) laminates. The parameters of the 18 specimens studied herein are concrete compressive strength, steel reinforcement ratio, and the number...

  • Experimental investigation on the effect of longitudinal reinforcement on shear strength of fibre reinforced polymer reinforced concrete beams. Alam, M.S.; Hussein, A. // Canadian Journal of Civil Engineering;Mar2011, Vol. 38 Issue 3, p243 

    The shear design equation of CSA S806-02 does not consider the effect of the axial stiffness of the reinforcing bars for beams with effective depth greater than 300 mm. This paper examines the shear strength of such beams without stirrups. A total of 16 beams reinforced with GFRP, CFRP, and...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library