TITLE

Exposure to Direct and Scatter Radiation with Use of Mini-C-Arm Fluoroscopy

AUTHOR(S)
Giordano, Brian D.; Ryder, Steven; Baumhauer, Judith F.; Digiovanni, Benedict F.
PUB. DATE
May 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;May2007, Vol. 89-A Issue 5, p948
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Mini-c-arm fluoroscopy has become an important resource to the orthopaedic surgeon. Exposure of the orthopaedic surgical team to radiation during standard large-c-arm fluoroscopy has been well studied; however, little is known about the amount of exposure to which a surgical team is subjected with the use of mini-c-arm fluoroscopy. Moreover, there is controversy regarding the use of protective measures with mini-c-arm fluoroscopy. Methods: We evaluated the use of mini-c-arm fluoroscopy during a simulated surgical procedure to quantify the relative radiation doses at various locations in the operative field. A standard calibrated mini-c-arm fluoroscope was used to image a phantom upper extremity with thirteen radiation dosimeters placed at various distances and angulations to detect radiation exposure. Results: After 155 sequential fluoroscopy exposures, totaling 300.2 seconds of imaging time, only the sensor placed in a direct line with the imaging beam recorded a substantial amount of measurable radiation exposure. Conclusions: The surgical team is exposed to minimal radiation during routine use of mini-c-arm fluoroscopy, except when they are in the direct path of the radiation beam.
ACCESSION #
25019638

 

Related Articles

  • Physician-received scatter radiation with angiography systems used for interventional radiology: comparison among many X-ray systems. Chida, Koichi; Morishima, Yoshiaki; Inaba, Youhei; Taura, Masaaki; Ebata, Ayako; Takeda, Ken; Shimura, Hirotaka; Zuguchi, Masayuki // Radiation Protection Dosimetry;May2012, Vol. 149 Issue 4, p410 

    Radiation protection for interventional radiology (IR) physicians is very important. Current IR X-ray systems tend to use flat-panel detectors (FPDs) rather than image intensifiers (IIs). The purpose of this study is to test the hypothesis that there is no difference in physician-received...

  • Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk? Hafez, M. A.; Smith, R. M.; Matthews, S. J.; Kalap, G.; Sherman, K. P. // Archives of Orthopaedic & Trauma Surgery;Jun2005, Vol. 125 Issue 5, p330 

    Introduction Previous studies reported that the radiation exposure to the hands of orthopaedic surgeons was far below the acceptable limit. However, the risk could have been underestimated as some factors were overlooked, namely monitoring trainees during average workload, placing dosimeters...

  • Awareness and attitudes amongst basic surgical trainees regarding radiation in orthopaedic trauma surgery. Khan, F. R.; Ul-Abadin, Z.; Rauf, S.; Javed, A. // Biomedical Imaging & Intervention Journal;Mar2010, Vol. 6 Issue 1, p1 

    This study investigated the awareness and attitudes of basic surgical trainees. Trainees were asked to answer questions from a pre-set questionnaire. Fifty basic surgical trainees from England and Wales were involved in the study. The areas covered were basic knowledge of radiation hazards, use...

  • A STUDY ON THE RADIATION DOSE OF THE ORTHOPAEDIC SURGEON AND STAFF FROM A MINI C-ARM FLUOROSCOPY UNIT. Mesbahi, Asghar; Rouhani, Alireza // Radiation Protection Dosimetry;2008, Vol. 132 Issue 1, p98 

    In this study, radiation exposure to the surgeon and supporting staff from a mini C-arm unit during fluoroscopically guided orthopaedic surgeries was studied. A Diadose dosemeter and Gamma-Scout meter were used for air-kerma measurements for primary and scattered radiations. The entrance dose of...

  • RADIATION EXPOSURE TO THE EYE LENS OF ORTHOPAEDIC SURGEONS DURING VARIOUS ORTHOPAEDIC PROCEDURES. Romanova, K.; Vassileva, J.; Alyakov, M. // Radiation Protection Dosimetry;2015 Special Issue, Vol. 165, p310 

    The aim of the present study was to assess the radiation dose to the eye lens of orthopaedic surgeons during various orthopaedic procedures and to make efforts to ensure that radiation protection is optimised. The study was performed for Fractura femoris and Fractura cruris procedures performed...

  • Occupational Radiation Exposure from C Arm Fluoroscopy During Common Orthopaedic Surgical Procedures and its Prevention. MAHAJAN, ANUPAM; SAMUEL, SUMANT; SARAN, ATUL K.; MAHAJAN, M. K.; MAM, M. K. // Journal of Clinical & Diagnostic Research;Mar2015, Vol. 9 Issue 3, p1 

    Background: Image intensifiers have become popular due to the concept of minimally invasive surgeries leading to decreasing invasiveness, decreased operative time, and less morbidity. The drawback, however, is an increased risk of radiation exposure to surgeon, patient and theatre staff. These...

  • A comparative study about ionizing radiation emitted during radiological 'skyline' view of the wrist in pronation versus supination. Vaiss, Lucile; Ichihara, Satoshi; Ramirez, Dallan; Hendriks, Sarah; Liverneaux, Philippe; Facca, Sybille // European Journal of Orthopaedic Surgery & Traumatology;Feb2015, Vol. 25 Issue 2, p309 

    The dorsal tangential view to the distal radius or 'skyline,' used to control the length of the screws for the ORIF with volar plates, is carried out in supination (fluoroscope vertical) or in pronation (fluoroscope horizontal). The purpose of this study was to compare the dose of ionizing...

  • Evaluation of radiation dose during pacemaker implantations. Tsapaki, V.; Christou, A.; Spanodimos, S.; Nikolaou, N.; Poulianitou, A.; Triantopoulou, Ch.; Patsilinakos, S. // Radiation Protection Dosimetry;Sep2011, Vol. 147 Issue 1/2, p75 

    The purpose was to evaluate patient radiation doses and compare with other interventional procedures. One hundred and twenty-eight procedures were carried out with a recently installed mobile undercouch C-arm machine with a 23-cm diameter image intensifier. The radiation dose is provided by the...

  • Equipment performance and radiation protection status in X-ray fluoroscopy units in Sudan. Ahmed, Nada A.; Nayl, A. I.; Suliman, I. I. // Radiation Protection Dosimetry;Feb2012, Vol. 148 Issue 2, p174 

    The number of fluoroscopy and fluoroscopically guided procedures has been substantially growing in developing countries at the same time advanced and sophisticated equipment are used in some hospitals. However, radiation protection requirements are not necessarily well adopted. In this study...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics