TITLE

Zero-voltage-switching DC/AC inverter

AUTHOR(S)
Wang, C.-M.
PUB. DATE
May 2007
SOURCE
IET Electric Power Applications;May2007, Vol. 1 Issue 3, p387
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A novel zero-voltage-switching (ZVS) DC/AC inverter is proposed. The proposed inverter can not only provide output voltage that is higher or lower than DC input voltage but can also use the pulse-width modulation (PWM) control technique. Furthermore, in the proposed inverter, besides operating at constant frequency, all semiconductor devices operate at soft-switching without additional voltage stress and current stress. A design example of 1000 W ZVS–PWM buck–boost inverter is examined to assess the inverter performance.
ACCESSION #
25017812

 

Related Articles

  • Coordinated Control of Dual PWM Converter for Elevator Drives. Han Shuang; Zheng Jiong; Luo Zhiqun; Wan Jianru // Elevator World;Jul2012, Vol. 60 Issue 7, p50 

    The article focuses on the coordinated control of dual pulse-width modulation (PWM) converters integrating elevator drives with energy feedback. It states that the energy difference between the rectifier and inverter per unit time can decrease if the power flow of the rectifier equals the...

  • Inverter Technology. MIX, JOHN // ASHRAE Journal;May2014, Vol. 56 Issue 5, p34 

    The article discusses inverter technology, where variable speed compressor technology consists of a static inverter, that converts incoming alternating current (ac) to direct current (dc) and uses pulse-width modulation for production of ac of desired frequency, and compressor. It discusses the...

  • An IFOC-DSVPWM Based DC-Link Voltage Compensation of Z-Source Inverter Fed Induction Motor Drive for EVs. Akkarapaka, Ananda Kumar; Singh, Dheerendra // Advances in Power Electronics;8/13/2015, Vol. 2015, p1 

    The drop in DC-link voltage of adjustable speed drives (ASD) occurs mainly due to the increase in output power demands. This may lead to inefficient operation and eventually the tripping of the drive. This paper presents a Double Space Vector Pulse Width Modulation (DSVPWM) technique for...

  • Single-phase multilevel inverter topologies with self-voltage balancing capabilities. Gautam, Shivam Prakash; Kumar, Lalit; Gupta, Shubhrata // IET Power Electronics;2018, Vol. 11 Issue 5, p844 

    In this study, two new structures of single-phase hybrid multilevel inverter are proposed for both symmetrical and asymmetrical configurations that can be employed in drives and control of electrical machines and connection of renewable energy sources. The proposed configuration uses a less...

  • Line-modulation-based flux-weakening control for permanent-magnet synchronous machines. Wei Wang; Jinghao Zhang; Ming Cheng // IET Power Electronics;2018, Vol. 11 Issue 5, p930 

    A line-modulation-based flux-weakening control is proposed for surface-mounted permanent-magnet synchronous machines. To evaluate the average dc bus voltage utilisation, the maximum line-modulation-ratio, which cannot be >1, is defined. If the maximum line-modulation-ratio is equal to 1, the...

  • Dynamic voltage restorer based on multilevel inverter with adjustable dc-link voltage. Babaei, Ebrahim; Kangarlu, Mohammad Farhadi; Sabahi, Mehran // IET Power Electronics;Mar2014, Vol. 7 Issue 3, p576 

    Dynamic voltage restorer (DVR) is a power electronic converter-based custom power device used to compensate for voltage variations. The inverter used in the DVR structure can have different topologies. Multilevel inverters are a good candidate to be used in the DVR structure especially in higher...

  • The X-connected inverter: a topology with higher fundamental and reduced low-order harmonic voltages. Maiti, Dipten; Biswas, Sujit K. // IET Power Electronics;Nov2013, Vol. 6 Issue 9, p1851 

    A new inverter topology is presented in the paper, which produces a reduced low-order harmonic voltage waveform because of a natural harmonic cancellation process. Two switches of each limb operate at low switching frequency, whereas the other two switches of the same limb operate at higher...

  • Performance and Measurement of Current Control Schemes in Grid connected Inverters. Yuvaraja, T.; Gopinath, M. // Australian Journal of Basic & Applied Sciences;Jun2014, Vol. 8 Issue 9, p163 

    Background: Applications such as digital based control in grid connected output currents are measured accurately. So obtaining the accuracy I must in the design consideration. The proposed work analyze the single and three phase measurement of grid connected inverter and the current control...

  • The Control Technology of the Z-source Three-phase Four-leg Inverter based on Computer Simulation. Ming Su; Xueyan Ma; Yan Sun // Advanced Materials Research;2014, Vol. 981, p688 

    Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same leg conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.