ABSTRACT
The article presents a study that investigates the advantages of using carbon dioxide laser in automotive interiors manufacturing applications. According to the author, laser is an ideal tool in interior applications because it does not require downtime and replacements. The study reveals that using laser process increases in the areas of on-metallic panels and components which owe its success to the advancement of laser sources that offer quality performance and reliability features.
ACCESSION #
24621431

 

Related Articles

  • CO2 Laser Beam - Biological Tissue Interaction with Reference to Ablation. Coutouly, J.-F.; Deprez, P.; Breaban, F.; Longuemard, J.-P. // Lasers in Engineering (Old City Publishing);2009, Vol. 19 Issue 3/4, p213 

    Laser ablation of biological materials (human or animal tissues) is of definite interest. For example companies working in the food-processing industry wish to cut or clean animal material in conditions of optimum hygiene. In this area, lasers can an extremely interesting alternative. This paper...

  • Tailor made. Farish, Mike // Automotive Manufacturing Solutions;Mar/Apr2009, p40 

    The article discusses improvements on the tailor blank process where two or more pieces of metal are joined together to be pressed into a final part, in a way that enables that part to have customized properties. Initially, carbon dioxide laser was the norm in tailor blank production but the...

  • Wet bone ablation with mechanically Q-switched high-repetition-rate CO[sub 2] laser. Ivanenko, M.M.; Hering, P. // Applied Physics B: Lasers & Optics;1998, Vol. 67 Issue 3, p395 

    Abstract. Carbonization-free ablation of bone tissue with 400-ns pulses from a Q-switched CO[sub 2] laser using a miniature water spray is demonstrated. An ablation threshold of 1.4J/cm[sup 2], an optimal energy density of 9-10J/cm[sup 2], and a corresponding specific ablation energy of 25-30...

  • Hard tissue ablation with a free running Er:YAG and a Q-switched CO[sub 2] laser: a comparative study. Stanislawki, M.; Meister, J.; Mitra, T.; Ivanenko, M.M.; Zanger, K.; Hering, P. // Applied Physics B: Lasers & Optics;2001, Vol. 72 Issue 1, p115 

    Abstract. The Er:YAG and the CO[sub 2] laser are competitors in the field of hard tissue ablation. The use of Er:YAG lasers (2.94 micro m, pulse length tau[sub L] of 100 to 200 micro s) show smaller areas of thermal defects then "superpulsed" CO[sub 2] lasers with pulse lengths of approximately...

  • Ablating light optics. Coppinger, Rob // Electro Optics;May2012, Issue 223, p42 

    The article reports on the development of a manufacturing process for optical glass components by scientists at the Fraunhofer Institute for Laser Technology (ILT) using carbon dioxide laser or 1030nm ultra short pulse laser ablation.

  • Sealed CO2 lasers update industrial processing. Bunis, Jenifer // Laser Focus World;Jun95, Vol. 31 Issue 6, p49 

    Focuses on the growth of carbon dioxide laser use in industrial processing. Factors affecting the growth; Benefits of cutting with a laser; Application of the lasers on desktop manufacturing; Applications on textile cutting; Applications on laser marketing.

  • Novel technique for low-jitter dual-laser synchronization in a thin film deposition system. Mukherjee, Pritish; Cuff, John B.; Witanachchi, Sarath // Review of Scientific Instruments;May2001, Vol. 72 Issue 5, p2380 

    The need for precise laser pulse synchronization in a dual-laser ablation system to optimize the quality of the deposited thin films has been previously demonstrated. We present, in this article, a novel technique for the synchronization of an excimer and a CO[sub 2] laser with synchronization...

  • High-resolution ablation of amorphous polymers using CO2 laser irradiation. Sonnenschein, Mark F.; Roland, C. Michael // Applied Physics Letters;7/30/1990, Vol. 57 Issue 5, p425 

    Etching of various amorphous polymers by the application of CO2 laser radiation (10.6 μm) is described. By passage of the radiation through a high-resolution mask in contact with the polymer surface, this ablation can produce images having submicron resolution and good edge acuity. The laser...

  • Bucking the Trend. Guttman, Cheryl // Dermatology Times;Jan2003, Vol. 24 Issue 1, p50 

    Considers the use of ablation with a short-pulsed carbon dioxide laser for facial rejuvenation and improvement of wrinkles. Advantages of carbon dioxide laser resurfacing; Adverse consequences of the method; Application of other resurfacing approaches.

Share

Read the Article

Courtesy of

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics