Laboratory arrangement for soft x-ray zone plate efficiency measurements

AUTHOR(S)
Bertilson, Michael C.; Takman, Per A. C.; Holmberg, Anders; Vogt, Ulrich; Hertz, Hans M.
PUB. DATE
February 2007
SOURCE
Review of Scientific Instruments;Feb2007, Vol. 78 Issue 2, p023106
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We demonstrate a laboratory-scale arrangement for rapid and accurate measurements of the absolute and local efficiency of soft x-ray micro zone plates in the water window. This in-house instrument is based on a single-line λ=2.88 nm liquid-jet laser-plasma source. Measurements are performed by a simultaneous comparison of first diffraction-order photon flux with the flux in a calibrated reference signal. This arrangement eliminates existing source emission fluctuations. The performance of the method is demonstrated by the result from measurements of two ∼55 μm diameter nickel micro zone plates, showing a groove efficiency of 12.9%±1.1% and 11.7%±1.0%. Furthermore, we show that spatially resolved efficiency mapping is an effective tool for a detailed characterization of local zone plate properties. Thus, this laboratory-scale instrument allows rapid feedback to the fabrication process which is important for future improvements.
ACCESSION #
24602023

 

Related Articles

  • Table-top Soft X-ray Microscopy with a Laser-induced Plasma Source Based on a Pulsed Gas-jet. Müller, Matthias; Mey, Tobias; Niemeyer, Jürgen; Lorenz, Maike; Mann, Klaus // AIP Conference Proceedings;2016, Vol. 1764 Issue 1, p1 

    A table-top soft x-ray microscope based on a long-term stable and nearly debris-free laser plasma from a pulsed nitrogen gas jet target is presented. The microscope operates in the "water window" region at 2.88 nm wavelength. The emitted soft x-ray radiation is focused by an ellipsoidal...

  • Observation of Phase Objects by Using an X-ray Microscope with a Foucault Knife-Edge. Watanabe, N.; Sasaya, T.; Imai, Y.; Iwata, S.; Zama, K.; Aoki, S. // AIP Conference Proceedings;9/9/2011, Vol. 1365 Issue 1, p313 

    An x-ray microscope with a zone plate was assembled at the synchrotron radiation source of BL3C, Photon Factory. A Foucault knife-edge was set at the back focal plate of the objective zone plate and phase retrieval was tested by scanning the knife-edge. A preliminary result shows that scanning...

  • Zernike-type phase contrast X-ray microscopy at 4 keV photon energy with 60 nm resolution. Neuhäusler, Ulrich; Schneider, Gerd; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1255 

    X-ray microscopy in the multi-keV photon energy range offers unique possibilities to study thick dense samples with high spatial resolution. When employing a high numerical aperture (N.A.) condenser zone plate sample illumination in combination with a high resolution micro zone plate objective...

  • Phase zone plates for hard X-ray focusing. Vladimirsky, Yuli // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p615 

    The major obstacle for constructing a deep UV or X-ray lens is the low refraction and high absorption of materials in this region. Only a few Fresnel zones are utilized, so the diameter of an X-ray lens is of the order few microns, and the resolution is hardly better than that of a pinhole. The...

  • Fabrication of thick zone plates for multi-kilovolt X-rays. Du¨vel, A.; Rudolph, D.; Schmahl, G. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p607 

    Phase zone plates for multi-kilovolt X-rays with an outermost zone width of 16.9-30 nm and aspect ratios up to 177 were generated by a sputtered-sliced technology. The generated lenses of alternating Ni80Cr20 and SiO[sub 2] consist of 188-365 layers on borosilicate glass wires and were polished...

  • Imaging hard X-ray microscopy with a multilayer Fresnel zone plate. Awaji, Mitsuhiro; Suzuki, Yoshio; Takeuchi, Akihisa; Kamijo, Nagao; Tamura, Shigeharu; Yasumoto, Masato; Kohmura, Yoshiki // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p545 

    Preliminary experiments by use of a multilayer Fresnel zone plate (FZP) have been performed for bright-field imaging at 25kev hard X-rays. The #1500 gold mesh was selected as a test specimen. The mesh structure has been successfully observed in the bright-field images.

  • X-ray microbeam with sputtered-sliced Fresnel zone plate at Spring-8 undulator beamline. Suzuki, Y.; Awaji, M.; Kohmura, Y.; Takeuchi, A.; Kamijo, N.; Tamura, S.; Handa, K. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p535 

    Hard X-ray microbeam with sputtered-sliced Fresnel zone plate has been tested at SPring-8 undulator beam line. Focusing properties are evaluated in X-ray wavelength regions of 0.15-1.6 Å. The measured focal beam size is about 0.6 μm at an X-ray wavelength of 1.4 Å, and 0.7 μm at...

  • Liquid-nitrogen-jet laser-plasma source for compact soft x-ray microscopy. Jansson, P. A. C.; Vogt, U.; Hertz, H. M. // Review of Scientific Instruments;Apr2005, Vol. 76 Issue 4, p043503 

    We describe a liquid-nitrogen-jet laser-plasma source with sufficient brightness, uniformity, stability, and reliability to be suitable for compact water-window soft x-ray transmission microscopy. A cooled capillary nozzle arrangement allows long-term operation and avoids previously reported jet...

  • Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction. Rehbein, S.; Guttmann, P.; Werner, S.; Schneider, G. // AIP Conference Proceedings;9/9/2011, Vol. 1365 Issue 1, p32 

    The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/ΔE = 104 [1]. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics