TITLE

A study of the interactions between carboplatin and blood plasma proteins using size exclusion chromatography coupled to inductively coupled plasma mass spectrometry

AUTHOR(S)
Xie, Ruimin; Johnson, Willie; Rodriguez, Lorna; Gounder, Murugesan; Hall, Gene S.; Buckley, Brian
PUB. DATE
April 2007
SOURCE
Analytical & Bioanalytical Chemistry;Apr2007, Vol. 387 Issue 8, p2815
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
To study the carboplatin–protein interaction, a sensitive method using size exclusion chromatography coupled to inductively coupled plasma mass spectrometry (SEC–ICP–MS) was developed. The complexes formed between plasma proteins and carboplatin were monitored and identified with this method. Composite blood plasma samples from patients who were undergoing chemotherapy were analyzed, and carboplatin was found to bind plasma proteins. In addition, blank plasma samples were spiked with carboplatin and were analyzed as a time course study, and the results confirmed that carboplatin formed complexes with plasma proteins, primarily albumin and γ-globulin. To further substantiate the study, these two proteins were incubated with carboplatin. The binding between carboplatin and these proteins was then characterized qualitatively and quantitatively. In addition to a one-to-one binding of Pt to protein, protein aggregation was observed. The kinetics of the binding process of carboplatin to albumin and γ-globulin was also studied. The initial reaction rate constant of carboplatin binding to albumin was determined to be 0.74 M−1 min−1, while that for γ-globulin was 1.01 M−1 min−1, which are both lower than the rate constant of the cisplatin–albumin reaction previously reported.
ACCESSION #
24441205

 

Related Articles

  • Determination of ceruloplasmin in human serum by SEC-ICPMS. Lopez-Avila, Viorica; Sharpe, Orr; Robinson, William H. // Analytical & Bioanalytical Chemistry;Oct2006, Vol. 386 Issue 1, p180 

    This paper describes an analytical method for the determination of ceruloplasmin (Cp) in human serum. The method uses immunoaffinity chromatography and size-exclusion chromatography (SEC) to �purify� the serum sample prior to analysis of 63Cu and 65Cu by inductively-coupled plasma mass...

  • Biosynthesis of Cd-bound phytochelatins by Phaeodactylum tricornutum and their speciation by size-exclusion chromatography and ion-pair chromatography coupled to ICP—MS. Loreti, Valeria; Toncelli, Daniel; Morelli, Elisabetta; Scarano, Gioacchino; Bettmer, Jörg // Analytical & Bioanalytical Chemistry;Oct2005, Vol. 383 Issue 3, p398 

    Cd-bound phytochelatins (Cd–PCs) have been synthesised by incubation of Phaeodactylum tricornutum cell cultures with Cd and purified by size-exclusion chromatography–UV–Vis. These complexes, which were identified in previous work, have now been used as model substances to...

  • Hyphenated Techniques as Modern Detection Systems in Ion Chromatography. Wille, Andrea; Czyborra, Stefanie; Steinbach, Alfred // LC-GC Asia Pacific;Sep2009, Vol. 12 Issue 3, p1 

    This article describes the use of combined ion chromatography-mass spectrometry (IC-MS) and ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) to analyse potentially harmful compounds.

  • Fate of Copper in Copperized Dyes During Biological Waste Treatment I: Direct Dyes. Baugham, George L. // Textile Chemist & Colorist & American Dyestuff Reporter;Jan2000, Vol. 32 Issue 1, p51 

    Sorption coefficients were measured for 12 direct dyes using sludge from a municipal treatment plant and for two of the same dyes using sludge from a different municipal treatment plant that normally receives dyehouse effluent. Cupric ion sorption was measured as a control. The results show that...

  • ICP-MS: A Universally Sensitive GC Detection Method for Specialty and Electronic Gas Analysis. Geiger, William M.; Raynor, Mark W. // Spectroscopy;Nov2008, Vol. 23 Issue 11, p34 

    The article highlights the use of gas chromatography with inductively coupled plasma-mass spectrometry (GC-ICP-MS). It says that ICP-MS was designed primarily to replace atomic absorption and ICP-optical emission instrumentation for analysis of metals in aqueous and organic matrices. However, as...

  • Hyphenated Techniques in lon Chromatography. Wille, Andrea; Czyborra, Stefanie; Steinbach, Alfred // LC-GC Europe;Dec2007 Applications Book, Vol. 20, p42 

    This article describes the use of combined ion chromatography-mass spectrometry (IC-MS) and ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) to analyse potentially harmful compounds.

  • An approach to the arsenic status in cardiovascular tissues of patients with coronary heart disease. Román, D. A.; Pizarro, I.; Rivera, L.; Cámara, C.; Palacios, M. A.; Gómez, M. M.; Solar, C. // Human & Experimental Toxicology;Sep2011, Vol. 30 Issue 9, p1150 

    Among non-cancer effects of arsenic, cardiovascular diseases have been well documented; however, few are known about the arsenic fate in cardiovascular tissues. We studied the analytic bioinorganic arsenic behaviour in cardiovascular tissues from an arsenic exposure coronary heart disease...

  • Ceruloplasmin levels in human sera from various diseases and their correlation with patient's age and gender. Lopez-Avila, Viorica; Robinson, William H.; Lokits, Kirk // Health (1949-4998);Sep2009, Vol. 1 Issue 2, p104 

    Ceruloplasmin (Cp), a copper metalloprotein in human serum has been a valuable diagnostic marker in Wilson's disease where Cp levels tend to be low while high levels in serum were associated with myocardial infarction, neoplastic and inflammatory conditions. There is no standardized reference...

  • Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples. Yoshida, S.; Muramatsu, Y.; Katou, S.; Sekimoto, H. // Journal of Radioanalytical & Nuclear Chemistry;Jul2007, Vol. 273 Issue 1, p211 

    An online analytical system using ion chromatography (IC) followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the separate determination of I− and IO in aqueous solutions with a detection limit 0.1–1 μg 1/1. The total iodine concentration was also...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics