TITLE

HPLC-ICP-MS and HPLC-ES-MS/MS characterization of synthetic seleno-arsenic compounds

AUTHOR(S)
Kanaki, Katerina; Pergantis, Spiros A.
PUB. DATE
April 2007
SOURCE
Analytical & Bioanalytical Chemistry;Apr2007, Vol. 387 Issue 8, p2617
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Various toxicological and metabolic interactions have been reported to exist between arsenic and selenium. In the present study, synthetic seleno-arsenic compounds, potentially suitable for probing metabolic interactions between these two elements, were prepared and tentatively characterized by using high-performance liquid chromatography (HPLC)–electrospray tandem mass spectrometry and HPLC–inductively coupled plasma mass spectrometry. In analogy to the recently identified thio-arsenic species, which can be prepared from their corresponding oxo-arsenic species via reaction with H2S, the seleno-arsenic compounds were also derived from oxo-arsenic compounds via reaction with H2Se. [Figure not available: see fulltext.]
ACCESSION #
24441173

 

Related Articles

  • Simocyclinones: diversity of metabolites is dependent on fermentation conditions3. Schimana, J; Walker, M; Zeeck, A; Fiedler, H-P // Journal of Industrial Microbiology & Biotechnology;Sep2001, Vol. 27 Issue 3, p144 

    Simocyclinones, a novel group of angucyclinone antibiotics, are produced by Streptomyces antibioticus T� 6040. The compounds show antibacterial and antitumor properties. In submerged cultivation, the production of simocyclinones is strongly dependent on the carbon and nitrogen sources used...

  • Characterization of Water-Soluble Macromolecular Substances in Cloud Water. Feng, Jinsheng; Möller, Detlev // Journal of Atmospheric Chemistry;Jul2004, Vol. 48 Issue 3, p217 

    In this contribution we present to our knowledge the first investigations of macromolecular, often called humic-like substances (HULIS) in cloud water samples and compare them with water-soluble extracts from atmospheric PM2.5, soils and waters to study its possible origin. Chemical analysis was...

  • Quantification with HPLC–MS/MS for environmental issues: quality assurance and quality assessment. Bester, Kai // Analytical & Bioanalytical Chemistry;May2008, Vol. 391 Issue 1, p15 

    The article presents research on the quality of high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS) as a tool in environmental chemistry. It is noted that HPLC-MS/MS is the method of choice for quantifying polar compounds such as pesticides and...

  • HPLC and LC-MS analysis of sinomenine and its application in pharmacokinetic studies in rats. Li-hong LONG; Peng-fei WU; Xiang-long CHEN; Zui ZHANG; Yu CHEN; Yi-yong LI; You JIN; Jian-guo CHEN; Fang WANG // Acta Pharmacologica Sinica;Nov2010, Vol. 31 Issue 11, p1508 

    Aim:To improve and validate analytical methods based on HPLC and liquid chromatography coupled to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the quantitative measurement of sinomenine in rat plasma and brain tissue.Methods:The separation of analytes and the internal...

  • Metabolism and pharmacokinetics of nibentan in human blood plasma. Appolonova, S.; Valiev, V.; Dikunets, M.; Kukharenko, A.; Rodchenkov, G.; Zeltyn', E.; Bezprozvannyi, A.; Gorshkov, V.; Radzevich, A. // Pharmaceutical Chemistry Journal;Jul2010, Vol. 44 Issue 7, p341 

    n HPLC method with electrospray ionization and ion-trap mass spectral detection (LC-ESI/MSD Ion Trap SL) for determining nibentan metabolites in human blood plasma is described. The proposed method provides simultaneous determination of nibentan and its metabolites in blood plasma. Three...

  • Determination of 30 Synthetic Food Additives in Soft Drinks by HPLC/Electrospray Ionization-Tandem Mass Spectrometry. HUI GAO; MINLI YANG; MINGLIN WANG; YANSHENG ZHAO; YA CAO; XIAOGANG CHU // Journal of AOAC International;Jan/Feb2013, Vol. 96 Issue 1, p110 

    The article presents a study on a high performance liquid chromatography (HPLC)/electrospray ionization-tandem mass spectrometry (MS/MS) developed for determining synthetic food additives in soft drinks. It notes that synthetic ingredients are added to soft drinks to ensure the required...

  • Improving the Effectiveness of Method Translation for Fast and High Resolution Separations. Woodman, Michael // LC-GC Europe;Dec2006, Vol. 19 Issue 12, p41 

    The increased availability of sub-2-micron (STM) columns and increased demand for mass spectrometer friendly methods has led to a strong trend toward conversion of existing HPLC methods to smaller diameter and smaller particle size columns. While the conversion is a simple mathematical exercise...

  • Determination of Nalmefene by High-Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry. Fang, Wenfang B.; Andrenyak, David M.; Moody, David E.; Nuwayser, Elie S. // Journal of Analytical Toxicology;Apr2005, Vol. 29 Issue 3, p169 

    Describes a highly sensitive and selective method for the measurement of nalmefene in human and rabbit plasma and rabbit serum. Use of high performance liquid chromatography interfaced by electrospray ionization to a tandem mass spectrometric detector; Peak-area ratio of blank plasma or serum...

  • Determination of amlodipine in human plasma by electrospray ionization LC-MS/MS method: validation and its stability studies. Sirikatitham, Anusak; Panrat, Kamon; Tanmanee, Niwan // Songklanakarin Journal of Science & Technology;2008, Vol. 30 Issue 4, p455 

    A sensitive and specific high-performance liquid chromatography combined with electrospray ionization (ESI) tandem mass spectrometry (LC-MS/MS) method, operating in the positive ionization mode, for quantifying of amlodipine in human plasma using tizanidine as internal standard (I.S.) was...