TITLE

The Objective and Subjective Evaluation of Multichannel Expansion in Wide Dynamic Range Compression Hearing Instruments

AUTHOR(S)
Plyler, Patrick N.; Lowery, Kristy J.; Hamby, Hilary M.; Trine, Timothy D.
PUB. DATE
February 2007
SOURCE
Journal of Speech, Language & Hearing Research;Feb2007, Vol. 50 Issue 1, p15
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: The effects of multichannel expansion on the objective and subjective evaluation of 20 listeners fitted binaurally with 4-channel, digital in-the-ear hearing instruments were investigated. Method: Objective evaluations were conducted in quiet using the Connected Speech Test (CST) and in noise using the Hearing in Noise Test (HINT) at 40, 50, and 60 dB SPL. Subjective evaluations were conducted by having each participant (a) rate their satisfaction regarding the amount of noise reduction they perceived daily and (b) indicate which expansion condition they preferred overall after a 2-week trial. Three expansion settings were programmed into the hearing aids: 4-channel expansion, expansion restricted to Channels 1 and 2 only, and expansion off. Results: Listeners performed significantly better in quiet (CST) and in noise (HINT) for the off condition than for either multichannel condition; however, restricting expansion to Channels 1 and 2 improved objective performance in quiet and in noise relative to the 4-channel condition. Conversely, satisfaction ratings were significantly greater for both multichannel conditions than for the off condition; however, satisfaction ratings were similar for the restricted and the 4-channel conditions. Overall, listeners preferred any form of multichannel expansion to no expansion; however, overall preference was similar for the restricted and the 4-channel conditions. Conclusions: Hearing instrument users prefer the use of multichannel expansion despite the fact multichannel expansion may significantly reduce the recognition of low-level speech in quiet and in noise. Although restricting expansion to Channels 1 and 2 (i.e., 2000 Hz and below) maintained subjective benefit for wide dynamic range compression hearing instrument users, the recognition of low-level speech was not completely preserved.
ACCESSION #
24286985

 

Related Articles

  • Interactions between Cognition, Compression, and Listening Conditions: Effects on Speech-in-Noise Performance in a Two-Channel Hearing Aid. Lunner, Thomas; Sundewall-ThorĂ©n, Elisabet // Journal of the American Academy of Audiology;Jul/Aug2007, Vol. 18 Issue 7, p604 

    This study which included 23 experienced hearing aid users replicated several of the experiments reported in Gatehouse et al (2003, 2006) with new speech test material, language, and test procedure. The performance measure used was SNR required for 80% correct words in a sentence lest....

  • Acoustic Analysis of Speech through a Hearing Aid: Consonant-Vowel Ratio Effects with Two-Channel Compression Amplification. Hickson, Louise; Thyer, Nick; Bates, Dianne // Journal of the American Academy of Audiology;Nov\Dec1999, Vol. 10 Issue 10 

    In this study, the consonant-vowel ratio (CVR) changes associated with varying the compression ratio and crossover frequency of two-channel syllabic compression amplification were examined. Consonant-vowel syllables were recorded at 60 and 75 dB SPL input levels to the hearing aid under 13...

  • Effective compression and noise reduction configurations for hearing protectors.  // Noise & Vibration Worldwide;Mar2008, Vol. 39 Issue 3, p32 

    The article focuses on three experiments that have been carried out to investigate the effects of compression and noise reduction configurations on the amount of noise reduction, speech intelligibility, and overall preferences using existing digital hearing aids. Experiment 1 reveals that the...

  • Variables Affecting the Use of Prescriptive Formulae to Fit Modern Nonlinear Hearing Aids. Kuk, Francis K.; Ludvigsen, Carl // Journal of the American Academy of Audiology;Sep1999, Vol. 10 Issue 9, p458 

    It is routine for audiologists to fit nonlinear hearing aids by using one of several current prescriptive formulae. While such an approach might result in acceptable fittings for single-channel analog compression hearing aids, its direct application to fitting current multichannel compression ...

  • The Objective and Subjective Evaluation of Low-Frequency Expansion in Wide Dynamic Range Compression Hearing Instruments. Lowery, Kristy J.; Plyler, Patrick N. // Journal of the American Academy of Audiology;Sep2007, Vol. 18 Issue 8, p641 

    The effects of low-frequency expansion on the objective and subjective evaluation of four channel in-the-ear hearing instruments was investigated. Three expansion settings were programmed in each device: expansion off, expansion restricted to channel one, and expansion restricted to channels one...

  • Older Listeners' Use of Temporal Cues Altered by Compression Amplification. Souza, Pamela E. // Journal of Speech, Language & Hearing Research;Jun2000, Vol. 43 Issue 3, p661 

    This study compared the ability of younger and older listeners to use temporal information in speech when that information was altered by compression amplification. Recognition of vowel-consonant-vowel syllables was measured for four groups of adult listeners (younger normal hearing, older...

  • Interactions of Hearing Aid Compression Release Time and Fitting Formula: Effects on Speech Acoustics. Ellison, John C.; Harris, Frances P.; Muller, Thomas // Journal of the American Academy of Audiology;Feb\Mar2003, Vol. 14 Issue 2, p59 

    The effects of the interaction of compression release time and prescribed gain on running speech processed through a hearing aid on KEMAR was investigated. A digital instrument was programmed to fit a mild to moderate sloping hearing loss using probe microphone measures to reach targets...

  • Compression in Hearing Aids: Why Fast Multichannel Processing Systems Work Well. Villchur, Edgar // Hearing Review;Jun2008, Vol. 15 Issue 6, p16 

    The article focuses on the fast multichannel amplitude compression in hearing aids. Studies investigate claims that fast multichannel compression reduces speech intelligibility. Findings reveal that unless listeners require enhanced loudness contrast cues to speech recognition, the reduction of...

  • MPO: A Forgotten Parameter in Hearing Aid Fitting. Kuk, Francis; Korhonen, Petri; Baekgaard, Lars; Jessen, Anders // Hearing Review;Jun2008, Vol. 15 Issue 6, p34 

    The article focuses on the maximum power output (MPO) as an important consideration in hearing aid selection. A low MPO means the hearing aid is saturated with distortion and experiences compression limitation at a low output level, while a high MPO suggests no distortion or saturation. It...