TITLE

Improving Tibial Component Coronal Alignment During Total Knee Arthroplasty with Use of a Tibial Planing Device

AUTHOR(S)
Patil, Shantanu; D'Lima, Darryl D.; Fait, James M.; Colwell Jr., Clifford W.
PUB. DATE
February 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Feb2007, Vol. 89-A Issue 2, p381
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: The outcomes of knee arthroplasty have been shown to be affected by component alignment. Intramedullary and extramedullary alignment instrumentation are fairly effective for achieving the desired mean tibial component coronal alignment. However, there are outliers representing >3° of varus or valgus alignment with respect to the anatomic tibial shaft axis. We measured the efficacy of a custom tibial planing device for reducing the outliers in tibial alignment. Methods: We designed a tibial planing tool in an effort to improve tibial alignment. In one cohort (100 knees), we used traditional intramedullary alignment instrumentation to make the tibial bone cut. In a second cohort (120 knees), we used intramedullary alignment instrumentation to make the cut and also used a custom tool to check the cut and to correct an inexact cut. Tibial tray alignment relative to the long axis of the tibial shaft was measured in the coronal and sagittal planes on postoperative radiographs. The target coronal alignment was 90° with respect to the tibial shaft axis (with <90° denoting varus alignment). A total of 100 anteroposterior radiographs and sixty-five lateral radiographs were analyzed for the group that was treated with traditional instrumentation alone, and a total of 120 anteroposterior radiographs and fifty-five lateral radiographs were analyzed for the group that was treated with use of the custom tibial planing device. Results: The mean coronal alignment of the tibial component was 89.5° ± 2.1° in the group that was treated with traditional instrumentation alone and 89.6° ± 1.4° in the group that was treated with use of the custom planing device. Although the mean coronal alignment was not significantly different, the number of outliers was substantially reduced when the custom planing device was used. All 120 components that had been aligned with: use of the custom planing device were within 3° of the target coronal alignment, compared with only eighty-seven of the 100 components that had been implanted with use of traditional intramedullary alignment alone (p = 0.05). Conclusions: The use of a simple, inexpensive tibial planing device reduced the number of outliers due to tibial tray malalignment. Tibial varus has been associated with a higher risk of failure. Improving the accuracy of tibial component alignment may reduce the potential for poor clinical outcomes.
ACCESSION #
23964966

 

Related Articles

  • Total knee arthroplasty using cementless keels and cemented tibial trays: 10-year results. Kolisek, Frank; Mont, Michael; Seyler, Thorsten; Marker, David; Jessup, Nenette; Siddiqui, Junaed; Monesmith, Eric; Ulrich, Slif // International Orthopaedics;Feb2009, Vol. 33 Issue 1, p117 

    The problem of early mechanical stability of cemented and cementless keels of the tibial component in total knee arthroplasty (TKA) is controversial. The purpose of this study was to assess clinical and radiographic outcomes of a cohort of 51 TKAs using a cemented platform with cementless keel...

  • The Need for Alternative Bearings. Laskin, Richard S. // Orthopedics;Sep2003, Vol. 26 Issue 9, p966 

    The article discusses the need to find alternative bearing surfaces in total knee arthroplasty. It states how polyethylene wear is a continuing problem. It discusses studies done in changing the properties of polyethylene itself. It states that it is useless to try improving polyethylene without...

  • Effect of limb rotation on radiographic alignment in total knee arthroplasties. Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven // Archives of Orthopaedic & Trauma Surgery;Apr2010, Vol. 130 Issue 4, p451 

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic...

  • Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty? Nunley, Ryan; Ellison, Bradley; Zhu, Jinjun; Ruh, Erin; Howell, Stephen; Barrack, Robert // Clinical Orthopaedics & Related Research;Mar2012, Vol. 470 Issue 3, p895 

    Background: Coronal alignment may impact clinical outcome and survivorship in TKA. Patient-specific instrumentation has been developed to restore mechanical or kinematic axis and potentially reduce component malpositioning. Although it is clear these instruments add cost, it is unclear whether...

  • Use of Porous Tantalum Metaphyseal Cones for Severe Tibial Bone Loss During Revision Total Knee Replacement. Meneghini, R. Michael; Lewallen, David G.; Hanssen, Arlen D. // Journal of Bone & Joint Surgery, American Volume;Jan2008, Vol. 90-A Issue 1, p78 

    Background: The best treatment method for large tibial bone defects during revision knee replacement has not been established. The purpose of this study was to determine the initial results obtained with a unique reconstructive implant, the porous tantalum metaphyseal cone, designed as an...

  • Radiographic Assessment of the Thickness Lost from Polyethylene Tibial Inserts That Had Been Sterilized Differently. Collier, Matthew B.; Engh, Jr., C. Anderson; Hatten, Kyle M.; Ginn, Stuart D.; Sheils, Todd M.; Engh, Gerard A. // Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1543 

    Background: Archived serial radiographs of knee replacements provide indirect evidence of the clinical performance of ultra-high molecular weight polyethylene tibial bearings. Our purpose was to determine the loss of thickness in polyethylene tibial inserts that were of the same design but had...

  • Bone mineral density changes of the proximal tibia after revision total knee arthroplasty. A randomised study with the use of porous tantalum metaphyseal cones. Jensen, Claus; Petersen, Michael; Schrøder, Henrik; Lund, Bjarne // International Orthopaedics;Sep2012, Vol. 36 Issue 9, p1857 

    Purpose: Forty patients were enrolled in a prospective randomised study using conventional method or 'Trabecular Metal Cone' (TM Cone) (Zimmer inc., Warsaw, USA) for reconstruction of bone loss of the proximal tibia during revision total knee arthroplasty (rTKA). The aim was to evaluate changes...

  • Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines. M. Therbo; B. Lund; K.-E. Jensen; H. Schrøder // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p63 

    Abstract Background  Bioactive coating of uncemented total knee arthroplasty (TKA) is believed to increase bone ingrowth and enhance early fixation of the TKA. In a prospective randomized study using radiostereometric analysis (RSA) we examined migrations of the tibial implant, in an...

  • Complications of fixed infrared emitters in computer-assisted total knee arthroplasties. Hernández-Vaquero, Daniel; Suárez-Vázquez, Abelardo // BMC Musculoskeletal Disorders;2007, Vol. 8, p71 

    Background: The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics