Failure Analysis of a Ceramic Bearing Acetabular Component

Poggie, Robert A.; Turgeon, Thomas R.; Coutts, Richard D.
February 2007
Journal of Bone & Joint Surgery, American Volume;Feb2007, Vol. 89-A Issue 2, p367
Academic Journal
Background: Alternative bearings have been explored in an attempt to improve the longevity of total hip prostheses. A Food and Drug Administration (FDA)-approved clinical study of a nonmodular acetabular component consisting of a porous metal shell, compression-molded polyethylene, and a ceramic liner inlay was discontinued following reports of early failures. Methods: Between October 1999 and January 2003, 429 patients were enrolled in a prospective study to evaluate a cementless ceramic-on-ceramic total hip arthroplasty design (Hedrocel ceramic bearing cup; lmplex, Allendale, New Jersey). Two hundred and eighty-two patients (315 hips) were treated with the experimental acetabular implant and 147 patients (157 hips) were treated with an acetabular implant that consisted of the same porous shell but an all- polyethylene liner. Clinical data including a Harris hip score and responses to the Short Form-12 (SF-12) health survey were collected preoperatively and at twelve and twenty-four months postoperatively. Serial radiographs were made preoperatively; at six weeks, three months, six months, and twelve months postoperatively; and annually thereafter. Retrieval analysis was performed on all failed explanted components. Failure was defined as fracture or displacement of the ceramic liner out of the acetabular component. In addition, biomechanical testing was performed on unimplanted acetabular components and mechanically altered cups in an effort to recreate the mechanisms of failure. Finite element analysis was used to estimate stress and strain within the ceramic liner under extreme physiologic loading conditions. Results: The ceramic liner failed in fourteen of the 315 experimental acetabular components; all of the failures were at the ceramic-polyethylene interface. Patients with a body weight of >91 kg had a 4.76 times greater odds of the ceramic liner failing than those who weighed ≤91 kg. Retrieval analysis demonstrated stripe and rim wear with evidence of adhesive wear, indicating a potentially high-friction interaction at the articulation. Finite element analysis demonstrated that the forces on the ceramic liner in cups subjected to extreme loading conditions were insufficient to cause fracture. Biomechanical testing was unable to reproduce an initial ceramic liner displacement in vitro; however, when the ceramic liner was forcibly displaced prior to biomechanical testing, complete displacement and eventual fracture of the ceramic liner resulted. Conclusions: We hypothesized that the combination of a high patient body weight, an extensive range of motion, and subluxation of the femoral head led to high friction at the articulation between the femoral head and the rim of the liner, which initiated displacement of the ceramic liner. Subsequent normal gait led to further displacement of the liner in all of the fourteen failed components and eventually to ceramic fracture in twelve of the fourteen components.


Related Articles

  • FDA Panel Examines MoM Hip Devices. SALE, KATHERINE; PORUCZNIK, MARY ANN // AAOS Now;Sep2013, Vol. 6 Issue 9, p1 

    The article reports that the U.S. Food and Drug Administration's (FDA) Orthopaedic and Rehabilitative Devices Panel (ORDP) have considered expert opinion on the risks and benefits related to the metal-on-metal (MoM) hip replacement and resurfacing devices. The open public hearing featured...

  • National and International Postmarket Research and Surveillance Implementation. Sedrakyan, Art; Paxton, Elizabeth; Graves, Stephen; Love, Rebecca; Marinac-Dabic, Danica // Journal of Bone & Joint Surgery, American Volume;2014 Supplement, Vol. 96 Issue Supp1, p1 

    The creation of a unique device identification (UDI) system for medical devices by the U.S. Food and Drug Administration has led to the implementation of the International Consortium of Orthopedic Registries (ICOR) initiative. The ICOR established a distributed data system to demonstrate the...

  • Influence of acetabular rim profile on hip dislocation. Maher, S. A.; Lipman, J. D. // Proceedings of the Institution of Mechanical Engineers -- Part H;Nov2006, Vol. 220 Issue 8, p881 

    Dislocation is the second most common complication in total hip arthroplasty, with reported incidences of up to 8 per cent. The authors' hypothesis is that, by modifying the rim of an acetabular component in order to shift the femoral neck contact position towards the periphery of the...

  • Improving the Accuracy of Acetabular Component Orientation: Avoiding Malpositioning. Moskal, Joseph T.; Capps, Susan G.; Scanelli, John A. // Journal of Bone & Joint Surgery, American Volume;6/5/2013, Vol. 95-A Issue 11, p1044 

    The article focuses on improving the accuracy of acetabular component orientation. The use of larger femoral head sizes in primary total hip arthroplasty has increased in recent years with the introduction of alternative bearings and reduced short-tern dislocation. Many factors can negatively...

  • Improving the Postmarket Surveillance of Total Joint Arthroplasty Devices. Mahomed, Nizar N.; Syed, Khalid; Sledge, Clement B.; Brennan, Troyen A.; Liang, Matthew H. // Open Rheumatology Journal;2008, Vol. 2, p7 

    Objective: To evaluate the FDA's approval process and postmarket surveillance strategies for THR devices. Design: The FDA Center for Devices and Radiological Health (CDRH) 510k releasable database was used to document approved THR devices. The CDRH Medical Device Reporting data files were used...

  • Post-market scrutiny sought. Lee, Jaimy // Modern Healthcare;1/21/2013, Vol. 43 Issue 3, p4 

    The article reports that the U.S. Food and Drug Administration's (FDA) proposal to require metal-on-metal hip implant manufacturers to prove their devices are effective and safe has resulted to calls for an improved post-market surveillance system for all medical devices.

  • A Distributed Health Data Network Analysis of Survival Outcomes. Banerjee, Samprit; Cafri, Guy; Isaacs, Abby J.; Graves, Stephen; Paxton, Elizabeth; Marinac-Dabic, Danica; Sedrakyan, Art // Journal of Bone & Joint Surgery, American Volume;2014 Supplement, Vol. 96 Issue Supp1, p7 

    The article presents an overview of the data extraction process to answer several medical device performance-related questions in total hip arthroplasty and total knee arthroplasty. To facilitate evidence-based decision-making on performance of medical devices, the U.S. Food and Drug...

  • Comparison of periprosthetic bone remodelling after implantation of anatomic and straight stem prostheses in total hip arthroplasty. Grochola, L. F.; Habermann, B.; Mastrodomenico, N.; Kurth, A. // Archives of Orthopaedic & Trauma Surgery;Apr2008, Vol. 128 Issue 4, p383 

    Total hip arthroplasty changes bone loading conditions in the proximal femur and induces adaptive remodelling of the periprosthetic bone. These remodelling processes depend on many implant-specific qualities, e.g. material and elasticity of the stem. The objective of this study was to...

  • Does the Number or Quality of Pluripotent Bone Marrow Stem Cells Decrease with Age? Kevin Garvin // Clinical Orthopaedics & Related Research;Dec2007, Vol. 465 Issue 1, p202 

    In the next 25 years, as the 37 million baby boomers age, we can expect a 400% increase in total joint arthroplasties that will challenge surgeons, the healthcare system, and the scientific community. The burden may be eased if we are able to manipulate side population stem cells and enhance...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics