TITLE

A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty

AUTHOR(S)
Matziolis, Georg; Krocker, Doerte; Weiss, Ulrike; Tohtz, Stephan; Perka, Carsten
PUB. DATE
February 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Feb2007, Vol. 89-A Issue 2, p236
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Despite the use of modern instruments in total knee arthroplasty, component malalignment remains a problem. Whether a computer-assisted implantation technique can improve the accuracy of the spatial positioning of an implant is a matter of debate. The objective of this study was to determine whether computer-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Methods: The spatial positioning of the implant in sixty total knee arthroplasties (thirty-two imageless computer-assisted and twenty-eight conventional implantations) was determined three-dimensionally with use of computed tomographic measurement, which allowed derotation and full extension of the knee in order to avoid projection-related imaging errors. Results: The overall mechanical axis showed a range of between 4.8° of valgus and 6.6° of varus alignment in the frontal plane for conventionally implanted arthroplasty components compared with a significantly smaller range of between 2.9° of valgus and 3.1° of varus alignment for computer-assisted implantations (p = 0.004). In relation to the tibial implant, the mean deviation (and standard deviation) from the mechanical axis was 2.0° ± 1.7° for the conventional surgical method and 1.4° ± 0.9° for the navigated implantation. The rotational deviation from the referenced axis of the femoral component was between 3.3° of internal rotation and 5.0° of external rotation for the conventional implantation method, with a mean deviation of 0.1° ± 2.2°. Femoral components implanted with computer assistance showed a deviation of between 4.7° of internal rotation and 2.2° of external rotation, with a mean deviation of 0.3° ± 1.4°. Conclusions: In this study, with our technique of filtering out projection-related imaging errors, computer-assisted implantation of total knee replacements improved the frontal and sagittal alignment of the femoral component but not of the tibial component. We found that the rotational alignment of the component was not improved through navigation by solely referencing to the epicondylar axis for the femur and the tuberosity for the tibia.
ACCESSION #
23964947

 

Related Articles

  • Trends in Total Knee Arthroplasty. Dennis, Douglas A. // Orthopedics;Sep2006 Supplement, Vol. 29, pS13 

    The success of total knee arthroplasty (TKA) over the past two decades of use has resulted in the implantation of TKA into younger patients who have increased functional requirements and demand increased implant longevity. Improved functional performance requires enhanced range of motion,...

  • Total knee replacement and health-related quality of life: factors influencing long-term outcomes.  // International Journal of Advances in Rheumatology;2009, Vol. 7 Issue 4, p129 

    Is total knee replacement (TKR) for osteoarthritis equally effective in all patients? This Spanish group prospectively followed TKR patients and confirmed that the procedure conferred substantial benefit across the board; however, the gains were reduced in patients who were female or obese.

  • A circumferentially flanged tibial tray minimizes bone-tray shear micromotion. Barker, D. S.; Tanner, K. E.; Ryd, L. // Proceedings of the Institution of Mechanical Engineers -- Part H;Nov2005, Vol. 219 Issue 6, p449 

    Aseptic loosening of the tibial component is the major complication of total knee arthroplasty. There is an association between early excessive shear micromotion between the bone and the tray of the tibial component and late aseptic loosening. Using non-linear finite element analysis, whether a...

  • Towards a standard in assessment of bone cutting for total knee replacement. Barrera, O. A.; Haider, H.; Garvin, K. L. // Proceedings of the Institution of Mechanical Engineers -- Part H;Jan2008, Vol. 222 Issue 1, p63 

    Arthroplasty outcome is influenced by the ‘quality’ of bone preparation for implant insertion. Surgeons face increasing choices of technique and instrumentation, yet clinical scoring methods assess the overall outcome and patient satisfaction but not the bone cuts directly....

  • The History of Mobile-bearing Total Knee Replacement Systems. Hamelynck, Karel J. // Orthopedics;Sep2006 Supplement, Vol. 29, pS7 

    The use of a mobile-bearing knee system is routine in modern total knee arthroplasty (TKA). There are indications for use of a mobile-bearing TKA for a growing number of patients. The design, however, was not always well appreciated. Fears of perioperative difficulties and lack of understanding...

  • Rationale for the Posterior-stabilized Rotating-platform Knee. Maniar, Rajesh // Orthopedics;Sep2006 Supplement, Vol. 29, pS23 

    The nonposterior-stabilized mobile-bearing knee and the posterior-stabilized fixed-bearing design have been successfully used for the past three decades. Lessons learned from their use have culminated in the design of a posterior-stabilized mobile-bearing knee that incorporates beneficial...

  • The P.F.C. Sigma RP-F Total Knee Arthroplasty: Designed for Improved Performance. Ranawat, Amar S.; Gupta, Sanjay K.; Ranawat, Chitranjan S. // Orthopedics;Sep2006 Supplement, Vol. 29, pS28 

    The new P.F.C. Sigma RP-F (rotating-platform high-flexion) knee has been designed to permit 155° of flexion after total knee arthroplasty (TKA) without compromising wear, polyethylene contact stresses, patellofemoral tracking, or stability. The purpose of this article is to describe the...

  • Clinical Results of Primary Low Contact Stress Cementless Total Knee Arthroplasty. Sorrells, R. Barry; Capps, Susan G. // Orthopedics;Sep2006 Supplement, Vol. 29, pS42 

    The published clinical and radiographic outcomes data for primary cementless low-contact stress (LCS) total knee arthroplasty (TKA) were examined. The majority of patients (92.6%) were pain free or had only mild pain, and excellent or good knee scores (99.1%) at follow-up. Patella difficulties...

  • The P.F.C. Sigma RP-F TKA Designed for Improved Performance: A Matched-pair Study. Gupta, Sanjay K.; Ranawat, Amar S.; Shah, Vineet; Zikria, Bashir A.; Zikria, Joseph F.; Ranawat, Chitranjan S. // Orthopedics;Sep2006 Supplement, Vol. 29, pS49 

    The press fit condylar P.F.C. Sigma RP-F (rotating-platform, high flexion) knee is designed to provide a range of motion (ROM) of 155° without compromising wear, polyethylene contact stresses, patellofemoral tracking, or stability. The first 50 TKA surgeries using the Sigma RP-F knee...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.