TITLE

A Prospective, Randomized Study of Computer-Assisted and Conventional Total Knee Arthroplasty

AUTHOR(S)
Matziolis, Georg; Krocker, Doerte; Weiss, Ulrike; Tohtz, Stephan; Perka, Carsten
PUB. DATE
February 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Feb2007, Vol. 89-A Issue 2, p236
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Despite the use of modern instruments in total knee arthroplasty, component malalignment remains a problem. Whether a computer-assisted implantation technique can improve the accuracy of the spatial positioning of an implant is a matter of debate. The objective of this study was to determine whether computer-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Methods: The spatial positioning of the implant in sixty total knee arthroplasties (thirty-two imageless computer-assisted and twenty-eight conventional implantations) was determined three-dimensionally with use of computed tomographic measurement, which allowed derotation and full extension of the knee in order to avoid projection-related imaging errors. Results: The overall mechanical axis showed a range of between 4.8° of valgus and 6.6° of varus alignment in the frontal plane for conventionally implanted arthroplasty components compared with a significantly smaller range of between 2.9° of valgus and 3.1° of varus alignment for computer-assisted implantations (p = 0.004). In relation to the tibial implant, the mean deviation (and standard deviation) from the mechanical axis was 2.0° ± 1.7° for the conventional surgical method and 1.4° ± 0.9° for the navigated implantation. The rotational deviation from the referenced axis of the femoral component was between 3.3° of internal rotation and 5.0° of external rotation for the conventional implantation method, with a mean deviation of 0.1° ± 2.2°. Femoral components implanted with computer assistance showed a deviation of between 4.7° of internal rotation and 2.2° of external rotation, with a mean deviation of 0.3° ± 1.4°. Conclusions: In this study, with our technique of filtering out projection-related imaging errors, computer-assisted implantation of total knee replacements improved the frontal and sagittal alignment of the femoral component but not of the tibial component. We found that the rotational alignment of the component was not improved through navigation by solely referencing to the epicondylar axis for the femur and the tuberosity for the tibia.
ACCESSION #
23964947

 

Related Articles

  • Trends in Total Knee Arthroplasty. Dennis, Douglas A. // Orthopedics;Sep2006 Supplement, Vol. 29, pS13 

    The success of total knee arthroplasty (TKA) over the past two decades of use has resulted in the implantation of TKA into younger patients who have increased functional requirements and demand increased implant longevity. Improved functional performance requires enhanced range of motion,...

  • Total knee replacement and health-related quality of life: factors influencing long-term outcomes.  // International Journal of Advances in Rheumatology;2009, Vol. 7 Issue 4, p129 

    Is total knee replacement (TKR) for osteoarthritis equally effective in all patients? This Spanish group prospectively followed TKR patients and confirmed that the procedure conferred substantial benefit across the board; however, the gains were reduced in patients who were female or obese.

  • The History of Mobile-bearing Total Knee Replacement Systems. Hamelynck, Karel J. // Orthopedics;Sep2006 Supplement, Vol. 29, pS7 

    The use of a mobile-bearing knee system is routine in modern total knee arthroplasty (TKA). There are indications for use of a mobile-bearing TKA for a growing number of patients. The design, however, was not always well appreciated. Fears of perioperative difficulties and lack of understanding...

  • Clinical Results of Primary Low Contact Stress Cementless Total Knee Arthroplasty. Sorrells, R. Barry; Capps, Susan G. // Orthopedics;Sep2006 Supplement, Vol. 29, pS42 

    The published clinical and radiographic outcomes data for primary cementless low-contact stress (LCS) total knee arthroplasty (TKA) were examined. The majority of patients (92.6%) were pain free or had only mild pain, and excellent or good knee scores (99.1%) at follow-up. Patella difficulties...

  • Surgical Technique Tips and Pearls in Rotating-platform Knee Arthroplasty. Scott, Richard D. // Orthopedics;Sep2006 Supplement, Vol. 29, pS64 

    Rotating-platform mobile-bearing knee arthroplasties have potential advantages over fixed-bearing knee prostheses that may lead to better long-term wear of the polyethylene articulation. Their potential disadvantages include bearing spin-out that is usually the result of a tight posterior...

  • Patellar Crepitation in the P.F.C. Sigma Total Knee System. Ranawat, Amar S.; Ranawat, Chitranjan S.; Slamin, John E.; Dennis, Douglas A. // Orthopedics;Sep2006 Supplement, Vol. 29, pS68 

    Painless and painful patellar crepitation and patellar clunk syndrome represent a spectrum of peripatellar scar formation particular to posterior-stabilized knee components, although it may occur with cruciate-retaining designs as well. The formation of peripatellar infl ammatory scar tissue is...

  • Assessment of posterior stability in total knee replacement by stress radiographs: prospective comparison of two different types of mobile bearing implants. Louisia, S.; Siebold, R.; Canty, J.; Bartlett, R.; Bartlett, R J // Knee Surgery, Sports Traumatology, Arthroscopy;Sep2005, Vol. 13 Issue 6, p476 

    The aim of this study was to assess the posterior stability of two different designs of total knee replacement (TKR) with deep-dished mobile bearing (MB) implants using stress X-rays. In a prospective non-randomized consecutive study, 34 patients with primary osteoarthritis of the knee underwent...

  • Poorer survival after a primary implant during revision total knee arthroplasty. Meijer, Marrigje; Reininga, Inge; Boerboom, Alexander; Stevens, Martin; Bulstra, Sjoerd // International Orthopaedics;Mar2013, Vol. 37 Issue 3, p415 

    Purpose: Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA....

  • Soft-tissue balancing in total knee arthroplasty: cruciate-retaining versus posterior-stabilised, and measured-resection versus gap technique. Matsumoto, Tomoyuki; Muratsu, Hirotsugu; Kawakami, Yohei; Takayama, Koji; Ishida, Kazunari; Matsushita, Takehiko; Akisue, Toshihiro; Nishida, Kotaro; Kuroda, Ryosuke; Kurosaka, Masahiro // International Orthopaedics;Mar2014, Vol. 38 Issue 3, p531 

    Purpose: The purpose of this study was to prove the hypothesis that soft tissues are well balanced using the gap technique with a navigation system in cruciate-retaining (CR) and posterior-stabilised (PS) total knee arthroplasty (TKA), leading to better clinical outcomes compared with the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics