TITLE

Investigation of several parameters influencing signal generation in flow-through membrane-based enzyme immunoassay

AUTHOR(S)
Kolosova, Anna Yu.; De Saeger, Sarah; Eremin, Sergei A.; Van Peteghem, Carlos
PUB. DATE
February 2007
SOURCE
Analytical & Bioanalytical Chemistry;Feb2007, Vol. 387 Issue 3, p1095
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Rapid-response analytical tests that can be performed at the point of sampling are based on a visual detection system. The influence of different factors on the signal generation in a membrane-based enzyme immunoassay was investigated. The research was applied to a flow-through immunoassay for the detection of ochratoxin A (OTA). This assay format is a very convenient, simple and fast qualitative screening tool. Conjugates of OTA with horseradish peroxidase (HRP) and alkaline phosphatase (AP) were used as enzyme tracers. A new conjugate OTA-AP has been synthesized in our laboratory and its performance in the assay was compared with that of OTA-HRP. Different substrate systems for HRP and AP were compared. Several reagents, including polymers and surfactants, were tested for their possible effect on signal generation with the use of OTA-HRP conjugate. Polymers such as poly(vinyl alcohol) (PVA) and poly(ethylene glycol) (PEG) 6000 exerted a favourable effect on signal amplification, whereas surfactants negatively affected assay performance. The highest signal amplification (30–70% compared to the standard assay procedure) was achieved using 0.5% PVA in tetramethylbenzidine (TMB) Colorburst substrate solution and phosphate-buffered saline (PBS) for the washing step. It allowed more reliable visual estimation of the results from OTA-HRP assay. Exclusion of the detergent (Tween 20) from the washing solution exerted a favourable effect on assay performance using both enzyme tracers. The assay using OTA-HRP was more susceptible to matrix interferences than the assay with OTA-AP. Signal development in the matrix was better for the OTA-AP assay and visual estimation of the results was easier to perform in this case. For the analysis of spiked wheat samples, OTA-AP conjugate gave a more sensitive, stable and reproducible assay with a cut-off level of 4 μg kg−1 for OTA. The application of the new OTA-AP conjugate resulted in improved assay performance for the food samples.
ACCESSION #
23819313

 

Related Articles

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics