TITLE

Coulomb explosion of K-shell ionized krypton clusters studied by multiple-ion coincidence momentum imaging

AUTHOR(S)
Iwayama, H.; Nagaya, K.; Murakami, H.; Ohmasa, Y.; Yao, M.
PUB. DATE
January 2007
SOURCE
Journal of Chemical Physics;1/14/2007, Vol. 126 Issue 2, p024305
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Offset not found
ACCESSION #
23761868

Tags: IONS;  INTERMEDIATES (Chemistry);  ELECTRONS;  SPECTRUM analysis;  MOMENTUM distributions;  COULOMB excitation

 

Related Articles

  • Linear and electronic transport in strongly coupled binary ionic mixtures. Applications to the hydrogen�helium system. L�ger, D.; Deutsch, C. // Physics of Fluids B: Plasma Physics;Oct92, Vol. 4 Issue 10, p3162 

    This paper is devoted to a systematic investigation of linear transport properties in strongly coupled binary ionic mixtures of pointlike ions interacting solely through Coulomb interactions. The basic formalism rests upon suitable extensions of the Boltzmann-Ziman equation. Validity conditions...

  • Fragmentation of H2O Molecules by slow multiply charged Ions. Pes?ic, Z. D.; Hellhammer, R.; Sulik, B.; Stolterfoht, N. // AIP Conference Proceedings;12/8/2008, Vol. 1080 Issue 1, p88 

    We used the method of fragment ion spectroscopy to study ion-induced fragmentation of water molecules. An overview of our results for the energy and angular distribution of ionic fragments following the interaction with keV ions, ranging from 5 keV He2+ to 2 and 90 keV Ne9+, is presented....

  • First Results with TIGRESS and Accelerated Radioactive Ion Beams from ISAC: Coulomb Excitation of 20,21,29Na. Schumaker, M. A.; Hurst, A. M.; Svensson, C. E.; Wu, C. Y.; Becker, J. A.; Cline, D.; Hackman, G.; Pearson, C. J.; Stoyer, M. A.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Barton, C. J.; Boston, A. J.; Boston, H. C.; Buchmann, L.; Churchman, R.; Cifarelli, F.; Colosimo, S. J. // AIP Conference Proceedings;3/15/2009, Vol. 1099 Issue 1, p754 

    The TRIUMF-ISAC Gamma-Ray Escape Suppressed Spectrometer (TIGRESS) is a state-of-the-art ?-ray spectrometer being constructed at the ISAC-II radioactive ion beam facility at TRIUMF. TIGRESS will be comprised of twelve 32-fold segmented high-purity germanium (HPGe) clover-type ?-ray detectors,...

  • Charge state effect on K-shell ionization of aluminum by 600-3400 keV xenon (12 < q < 29) ion collisions. Song, Z.; Yang, Z.; Xiao, G.; Xu, Q.; Chen, J.; Yang, B. // European Physical Journal D -- Atoms, Molecules, Clusters & Opti;Oct2011, Vol. 64 Issue 2/3, p197 

    K-shell X-ray spectra of Al were measured by the interaction of 600-3400 keV Xe ( q = 12-29) ions with Al surface. The X-ray yields per incident ion were deduced and the K-shell ionization cross-sections were obtained from the experimental yield data. With the same incident energy, the K-shell...

  • Valence evaluation of LiMnO2 and related battery materials by x-ray absorption spectroscopy. Wadati, H.; Hawthorn, D. G.; Regier, T. Z.; Chen, G.; Hitosugi, T.; Mizokawa, T.; Tanaka, A.; Sawatzky, G. A. // Applied Physics Letters;7/12/2010, Vol. 97 Issue 2, p022106 

    We present an x-ray absorption study of the oxidation states of transition-metal-ions of LiMnO2 and its related materials, widely used as cathodes in Li-ion batteries. The comparison between the obtained spectrum and the configuration-interaction cluster-model calculations showed that the Mn3+...

  • Masses in Mass Spectrometry: Balancing the Analytical Scales. Busch, Kenneth L. // Spectroscopy;Nov2004, Vol. 19 Issue 11, p32 

    The article presents information on balancing the analytical scales. Ions, starting with atomic ions and growing into large ionic complexes containing thousands of atoms, routinely traverse our instruments, and reveal their structural secrets in a multitude of well-known experiments. analysis....

  • Strategies for Higher Throughput MS Analyses. Diehl, Diane M.; Balogh, Michael P. // Spectroscopy;Nov2004, Vol. 19 Issue 11, p36 

    The article presents information on strategies for higher throughput mass spectrometry (MS) analyses. Although LC-MS instruments are more robust now than 10 years ago, a number of practical performance issues still need to be considered before making the first injection. The gas-phase transition...

  • Distortion of the tetrahedral coordination of Fe(III) ions stabilized in ZSM-5 zeolite framework. Malykhin, S.; Anufrienko, V.; Hansen, E.; Kuznetsova, E.; Larina, T.; Zhidomirov, G. // Journal of Structural Chemistry;Sep2007, Vol. 48 Issue 5, p855 

    A simple qualitative method to analyze d-d-electronic transitions in cations of the transition elements in oxide matrices is proposed. In the particular case, all the excited states of interest differ only in the electronic configuration of d-orbitals, and the energies of transitions can be...

  • Composition profiles of InAs�GaAs quantum dots determined by medium-energy ion scattering. Quinn, P. D.; Wilson, N. R.; Hatfield, S. A.; McConville, C. F.; Bell, G. R.; Noakes, T. C. Q.; Bailey, P.; Al-Harthi, S.; Gard, F. // Applied Physics Letters;10/10/2005, Vol. 87 Issue 15, p153110 

    The composition profile along the [001] growth direction of low-growth-rate InAs�GaAs quantum dots (QDs) has been determined using medium-energy ion scattering (MEIS). A linear profile of In concentration from 100% In at the top of the QDs to 20% at their base provides the best fit to MEIS...

Share

Read the Article

Courtesy of your local library

Public Libraries Near You (See All)
Looking for a Different Library?

Other Topics