TITLE

Press-Fit Condylar Design Total Knee Arthroplasty

AUTHOR(S)
Rodricks, David J.; Patil, Shantanu; Pulido, Pamela; Colwell Jr., Clifford W.
PUB. DATE
January 2007
SOURCE
Journal of Bone & Joint Surgery, American Volume;Jan2007, Vol. 89-A Issue 1, p89
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: The Press-Fit Condylar total knee arthroplasty implant design has been used by many orthopaedic surgeons over the last twenty years. The design has survived with relatively minor modifications and remains a popular implant system today. The present study represents the fourteen to seventeen-year results for our patients who were described in our previous report on the eight to ten-year results. Methods: The senior author performed 160 consecutive total knee arthroplasties with use of the Press-Fit Condylar cruciate-retaining device in 134 patients between 1986 and 1989. The mean age of the patients at the time of the index procedure was 70.5 years. Follow-up data were available for sixty-three of sixty-four surviving knees. Surviving patients were followed for a mean of 15.8 years. The knees were evaluated on the basis of Knee Society function and clinical scores, radiographs, and survivorship analysis. Results: The mean Knee Society function score was 65, and the mean clinical score was 89. The overall survival rate of the knee was 91.5% with revision for any reason as the end point and 97.2% with aseptic loosening as the end point. The rate of revision of the tibial insert because of wear-related aseptic loosening was 2.5%. We found no relationship between revision and the shelf life or method of sterilization of the polyethylene insert. Radiolucent lines were present in 62% (twenty-one) of thirty-four knees; all radiolucent lines were nonprogressive. None of the implants were loose according to the criteria of the Knee Society. Conclusions: This long-term analysis indicates that the Press-Fit Condylar total knee implant is a successful implant system with excellent longevity.
ACCESSION #
23693803

 

Related Articles

  • Alignment Deviation Between Bone Resection and Final Implant Positioning in Computer- Navigated Total Knee Arthroplasty. Catani, Fabio; Biasca, Nicola; Ensini, Andrea; Leardini, Alberto; Bianchi, Luca; Digennaro, Vitantonio; Giannini, Sandro // Journal of Bone & Joint Surgery, American Volume;Apr2008, Vol. 90-A Issue 4, p765 

    Background: Computer-navigated total knee arthroplasty is aimed at improving accuracy in the positioning of prosthetic components and realigning the lower limb. The optimal position and orientation of the bone resection planes are targeted by the navigation system, but, after these are obtained,...

  • Two-stage total infected knee arthroplasty treatment with articulating cement spacer. Ocguder, Ali; Firat, Ahmet; Tecimel, Osman; Solak, Sukru; Bozkurt, Murat // Archives of Orthopaedic & Trauma Surgery;Jun2010, Vol. 130 Issue 6, p719 

    The treatment of infected total knee arthroplasty (TKA) is controversial and various. Two-stage prolonged reimplantation and 6-week systemic antibiotics use have been a gold standard of treatment in recent years. Seventeen knees of 17 patients, who underwent primary TKA and subsequently...

  • Fracture at the stem-condylar junction of a modular femoral prosthesis in a varus-valgus constrained total knee arthroplasty. Nikolopoulos, D.; Polyzois, I.; Magnissalis, E.; Bernard, P.; Michos, I. // Knee Surgery, Sports Traumatology, Arthroscopy;Jun2012, Vol. 20 Issue 6, p1071 

    We present a rare case of fracture of the modular femoral component in a varus-valgus constrained total knee arthroplasty (TKA) prosthesis which occurred 2 years after implantation. Both femoral and tibial components underwent a second revision using a constrained hinged TKA. Laboratory analysis...

  • 'Spin-out' - eine vermeidbare Komplikation in der Knieendoprothetik. Magin, M.N. // Der Orthopäde;Feb2014, Vol. 43 Issue 2, p175 

    Spin out of a rotating polyethylene (PE) platform after total knee replacement leads to rotation of the bearing compared to the fixed metal components of the prosthesis at the femur and tibia of approximately 90°. This complication occurs only in prosthesis designs which do not have a...

  • An alternative method to create extramedullary references in total knee arthroplasty. Seo, Jai-Gon; Moon, Young-Wan; Park, Sang-Hoon; Shim, Jae-Woo; Kim, Sang-Min // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2012, Vol. 20 Issue 7, p1339 

    Purpose: Historically, extramedullary techniques have focused on finding the femoral head center and referred mainly to the anterosuperior iliac spine (the FHC method) in total knee arthroplasty (TKA). The purpose of this study was to evaluate a new extramedullary alignment system that uses...

  • Assessing patient-oriented results after revision total knee arthroplasty. Baier, Clemens; Lüring, Christian; Schaumburger, Jens; Köck, Franz; Beckmann, Johannes; Tingart, Markus; Zeman, Florian; Grifka, Joachim; Springorum, Hans-Robert // Journal of Orthopaedic Science;Nov2013, Vol. 18 Issue 6, p955 

    Background: Revision total knee arthroplasties (TKA) have been performed with increasing frequency over the last 25 years. Methods: In this study, we retrospectively analyzed 78 patients who underwent 78 revision TKAs during the years 2003–2007 with an average follow-up of 81 months...

  • Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines. M. Therbo; B. Lund; K.-E. Jensen; H. Schrøder // Journal of Orthopaedics & Traumatology;Jun2008, Vol. 9 Issue 2, p63 

    Abstract Background  Bioactive coating of uncemented total knee arthroplasty (TKA) is believed to increase bone ingrowth and enhance early fixation of the TKA. In a prospective randomized study using radiostereometric analysis (RSA) we examined migrations of the tibial implant, in an...

  • Management of chronic lateral instability due to lateral collateral ligament deficiency after total knee arthroplasty: a case report. Unnanuntana, Aasis; Murphy, James E.; Petersilge, William J. // Journal of Medical Case Reports;2010, Vol. 4 Issue 1, p1 

    Introduction: Lateral instability following total knee arthroplasty (TKA) is a rare condition with limited report of treatment options. The objective of this case presentation is to demonstrate the outcomes of different surgical procedures performed in a single patient with lateral collateral...

  • Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty? Nunley, Ryan; Ellison, Bradley; Ruh, Erin; Williams, Brandon; Foreman, Keith; Ford, Adrienne; Barrack, Robert // Clinical Orthopaedics & Related Research;Mar2012, Vol. 470 Issue 3, p889 

    Background: Using patient-specific cutting blocks for TKA increases the cost to the hospital for these procedures, but it has been proposed they may reduce operative times and improve implant alignment, which could reduce the need for revision surgery. Questions/purposes: We compared TKAs...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM