TITLE

THE EVOLUTION OF LOCKED PLATES

AUTHOR(S)
Kubiak, Erik N.; Fulkerson, Eric; Strauss, Eric; Egol, Kenneth A.
PUB. DATE
December 2006
SOURCE
Journal of Bone & Joint Surgery, American Volume;Dec2006 Supplement 4, Vol. 88-A, p189
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The article focuses on a study to review the history of locked plates and provide recommendations for future trends in its clinical application. Fixation with conventional compression plates has its limitations. Locked plates have become an attractive alternative to conventional plates as they can be used as "bridge plates" to preserve fragmentary blood supply. Locked plates facilitate two-column support and have been clinically successful in situations in which dual compression plates.
ACCESSION #
23614853

 

Related Articles

  • Occipitocervical fusion with relief of odontoid invagination: atlantoaxial distraction method using cylindrical titanium cage for basilar invagination-case report. Yoshizumi, Tetsuya; Murata, Hidetoshi; Ikenishi, Yuriko; Sato, Mitsuru; Takase, Hajime; Tateishi, Kensuke; Nakanowatari, Satoshi; Suenaga, Jun; Kawahara, Nobutaka // Neurosurgical Review;Jul2014, Vol. 37 Issue 3, p519 

    A 65-year-old woman presented with basilar invagination manifesting as neck pain, dysesthesia around the lips, and truncal ataxia. The radiological findings demonstrated invagination of the odontoid process into the medulla oblongata and vertical atlantoaxial subluxation with C1 assimilation....

  • Experiencia con el sistema de placas bloqueadas (LCP) en el Hospital Susana López de Valencia -- Popayán, Colombia. Concha Sandoval, Juan Manuel // Acta Ortopedica Mexicana;ene/feb2007, Vol. 21 Issue 1, p8 

    The LCP (locking compression plate) system is a new type of extramedullary fixation for the management of fractures. A special design allows the surgeon to use it as a standard plate or as an internal fixator. The combined hole permits the use of standard screws, such as «locking» screws,...

  • Methodology for Dynamic Testing of Plates for Proximal Tibia Osteosynthesis. Vilimek, Miloslav; Sedlacek, Radek // Bulletin of Applied Mechanics;2011, Vol. 7 Issue 25, p12 

    In the presented study the problem of testing the plates for proximal tibia osteosynthesis was solved. Each specimen was loaded by repeated cyclic load. The required minimum number of cycles was 200 000, and minimum of required load was 2,5 kN. Tested specimens are in agreement with designated...

  • �z�letbe hatol� proximalis tibiat�r�sek ell�t�sa Doliaxialis NCB lemezzel. GERGELY, NOT L�SZL�; ZOLT�N, KISS // Magyar Traumatol�gia, Ortop�dia, K�zseb�szet, Plasztikai;2012, Vol. 55 Issue 3, p159 

    Of all long bone fractures in adults, only 10% involve the proximal tibia. Despite of the advanced implants and surgical technique, proximal tibia fractures involving articular surface, especially AO/OTA C-types, still remain a great challenge for the surgeon. The purpose of the study was to...

  • TRATAMENTUL CHIRURGICAL AL FRACTURILOR FEMURULUI DISTAL - STUDIU RETROSPECTIV PE 2 ANI. Putineanu, D. // Acta Medica Transilvanica;sep2012, Vol. 17 Issue 3, p81 

    Background: The treatment of distal femoral fractures has been associated with a high rate of complications for a long period of time. Although implant and surgical techniques have improved, plate osteosynthesis and intramedullary nailing have been accompanied by a high rate of infection,...

  • SURGICAL TREATMENT FOR DISTAL FEMORAL FRACTURES - A 2-YEAR RETROSPECTIVE STUDY. Putineanu, D. // Acta Medica Transilvanica;sep2012, Vol. 17 Issue 3, p224 

    Background: The treatment of distal femoral fractures has been associated with a high rate of complications for a long period of time. Although implant and surgical techniques have improved, plate osteosynthesis and intramedullary nailing have been accompanied by a high rate of infection,...

  • Zimmer reports implanting its first NCB plating system. PEDERSEN, AMANDA // Medical Device Daily;8/13/2010, Vol. 14 Issue 157, p1 

    The article reports on the first implantation of Zimmer's Non-Contact Bridging (NCB) Periprosthetic Plating System. The company claims that periprosthetic fracture care could be revolutionized by its new orthopedic trauma product. The full release of the device is scheduled in Fall 2010. The...

  • Development of an in vitro three dimensional loading-measurement system for long bone fixation under multiple loading conditions: a technical description. Janicek, John C.; Carson, William L.; Wilson, David A. // Journal of Orthopaedic Surgery & Research;2007, Vol. 2, p21 

    The purpose of this investigation was to design and verify the capabilities of an in vitro loading-measurement system that mimics in vivo unconstrained three dimensional (3D) relative motion between long bone ends, applies uniform load components over the entire length of a test specimen, and...

  • Clinical application of locked plating system in children. An orthopaedic view. Pretell-Mazzini, Juan; Zafra-Jimenez, Jose; Rodriguez Martin, Juan // International Orthopaedics;Oct2010, Vol. 34 Issue 7, p931 

    In recent years, the locked plating system has gained favour in the treatment of certain fractures in adults; however, there is not much information regarding its use in children. We think there could be some advantages and applications such as: an alternative to external fixation, the bridge...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.