TITLE

COMPUTER-ASSISTED SURGERY VERSUS MANUAL TOTAL KNEE ARTHROPLASTY: A CASE-CONTROLLED STUDY

AUTHOR(S)
Stulberg, S. David; Yaffe, Mark A.; Koo, Samuel S.
PUB. DATE
December 2006
SOURCE
Journal of Bone & Joint Surgery, American Volume;Dec2006 Supplement 4, Vol. 88-A, p47
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The article presents information on a study that determines the impact of experience with computer-assisted surgery on the manual technique of total knee arthroplasty. In the study, researchers compare the clinical, patient-perceived functional, and radio graphic results of manually performed total knee arthroplasty with use of computer-assisted surgery techniques.
ACCESSION #
23614839

 

Related Articles

  • Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Lim, Mui-Hong; Tallay, Andras; Bartlett, John // Knee Surgery, Sports Traumatology, Arthroscopy;May2009, Vol. 17 Issue 4, p341 

    The aim of our study was to compare the use of the Orthopilot Navigation system with conventional non-navigation technique for medial UKA with respect to the intraoperative mechanical limb alignment measurements and correlation with the postoperative radiological measurements. The postoperative...

  • The anterior surface of the femur as a new landmark for femoral component rotation in total knee arthroplasty. Talbot, Simon; Bartlett, John // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2008, Vol. 16 Issue 3, p258 

    Femoral component rotation is very important in avoiding complications and maximizing knee function following total knee arthroplasty. There is continuing debate over the most accurate axis to select intraoperatively to obtain the best results. There is considerable doubt over the ability of...

  • Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Rosenberger, Ralf; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2008, Vol. 16 Issue 3, p249 

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to...

  • Computer-assisted surgery can reduce blood loss after total knee arthroplasty. Hinarejos, Pedro; Corrales, Mónica; Matamalas, Antonia; Bisbe, Elvira; Cáceres, Enric // Knee Surgery, Sports Traumatology, Arthroscopy;May2009, Vol. 17 Issue 4, p356 

    The aim of this study was to compare blood loss and transfusion requirements in patients undergoing computer-assisted total knee arthroplasty (TKA) and patients operated with conventional instrumentation with intra-medullar guides. A prospective randomized study of 87 patients undergoing a TKA...

  • Accuracy of side-cutting implantation instruments for total knee arthroplasty. Martin, Arno; Sheinkop, Mitchell; Langhenry, Mary; Oelsch, Christian; Widemschek, Mark; Strempel, Archibald // Knee Surgery, Sports Traumatology, Arthroscopy;May2009, Vol. 17 Issue 4, p374 

    A new generation of implantation instruments were developed for quadriceps sparing surgical approaches during total knee arthroplasty (TKA). There is little information on the accuracy of the bone cuts performed with the side-cutting technique. A total of 100 patients were randomized to undergo...

  • Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Tingart, Markus; Lüring, Christian; Bäthis, Holger; Beckmann, Johannes; Grifka, Joachim; Perlick, Lars // Knee Surgery, Sports Traumatology, Arthroscopy;Jan2008, Vol. 16 Issue 1, p44 

    Restoration of the mechanical leg axis and component positioning are crucial factors affecting long-term results in total knee arthroplasty (TKA). In a prospective study, 1,000 patients were operated on either using a CT-free navigation system or the conventional jig-based technique. Leg...

  • Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Lüring, C.; Oczipka, F.; Perlick, L.; Tingart, M.; Grifka, J.; Bäthis, H. // Knee Surgery, Sports Traumatology, Arthroscopy;Mar2009, Vol. 17 Issue 3, p228 

    Computer assisted (CAS) knee surgery has been established in clinical routine. There is still no study that investigates clinical outcome. Fifty patients who received a primary total knee replacement 2 years before were investigated. These patients were divided into two groups of matched-pairs;...

  • Correction of Varus Deformity During TKA With Reduction Osteotomy. Mullaji, Arun; Shetty, Gautam // Clinical Orthopaedics & Related Research;Jan2014, Vol. 472 Issue 1, p126 

    Background: Reduction osteotomy (removing the posteromedial tibial bony flare) is one step to aid in achieving deformity correction in varus arthritic knees during TKA. However, the amount of deformity correction achieved with reduction osteotomy during TKA is unclear. Questions/purposes: We...

  • Computer-assisted surgery for total knee arthroplasty: more than just "boy toys" for the passionate few. Point. Hofmann, Aaron A. // Orthopedics;Sep2005, Vol. 28 Issue 9, p940 

    Focuses on the introduction of computer-assisted surgery for total knee arthroplasty in the U.S. in 2001. Different types of computer-assisted systems; Navigation systems that have been developed by manufacturers working in conjunction with orthopedic implant companies; Uses of the universal...

Share