TITLE

Comparison of Five Different Abdominal Access Trocar Systems: Analysis of Insertion Force, Removal Force, and Defect Size

PUB. DATE
September 2006
SOURCE
Surgical Innovation;Sep2006, Vol. 13 Issue 3, p183
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
No abstract available.
ACCESSION #
23411092

 

Related Articles

  • What can the operator actually feel when performing a laparoscopy? Picod, G.; Jambon, A.C.; Vinatier, D.; Dubois, P. // Surgical Endoscopy;Jan2005, Vol. 19 Issue 1, p95 

    The designing of a laparoscopic simulator, particularly the parameterizing of a force feedback system, has drawn attention to the question of characterizing laparoscopic gestures and effecting quantitative measurement of the various interactions between the organs and the instruments used to...

  • Functional luminal imaging probe geometric and histomorphologic analysis of abdominal wall wound induced by different trocars in pigs. Jingbo Zhao; Donghua Liao; McMahon, Barry; O'Donovan, Deidre; Schiretz, Rich; Heninrich, Russell; Gregersen, Hans // Surgical Endoscopy;May2009, Vol. 23 Issue 5, p1004 

    This study aimed to investigate wound geometry and tissue damage caused by several different trocar types using a quantitative functional luminal imaging probe (FLIP) geometric profile and histomorphologic analysis. Four pigs were used in this study. After general anesthesia, six different...

  • Safer trocar insertion for closed laparoscopic access: ex vivo assessment of an improved Veress needle. Nevler, Avinoam; Har-Zahav, Gil; Rosin, Danny; Gutman, Mordechai // Surgical Endoscopy;Feb2016, Vol. 30 Issue 2, p779 

    Introduction: Laparoscopic surgery is widely practiced surgical technique in the modern surgical toolbox. The Veress needle insertion technique, while faster and easier, is associated with higher rates of iatrogenic complications (injury to internal organs, major blood vessels,...

  • Force Required by Laparoscopic Trocar Devices to Penetrate the Human Female's Anterior Abdominal Wall. Baggish, Michael S.; Gandhi, Sandhya; Kasper, Greg // Journal of Gynecologic Surgery;Spring2003, Vol. 19 Issue 1, p1 

    This study was carried out to compare the force(s) required to penetrate the anterior abdominal wall by two laparoscopic trocar systems: disposable and reusable. Both systems utilized pyramidal cutting obturators measuring 11 mm in diameter. Twenty women were randomly distributed between the 2...

  • Fixity of ports to the abdominal wall during laparoscopic surgery: a randomized comparison of cutting versus blunt trocars. Hamade, A.; Issa, M.; Haylett, K.; Ammori, B.; Hamade, A M; Issa, M E; Haylett, K R; Ammori, B J // Surgical Endoscopy;Jun2007, Vol. 21 Issue 6, p965 

    Background: Dislodgement of ports from the abdominal wall is a common problem during laparoscopic surgery. The aim of this study was to evaluate port stability using either cutting or blunt-tipped trocars.Methods: Patients undergoing laparoscopic surgery were randomized...

  • A New Valve-Less Trocar for Urologic Laparoscopy: Initial Evaluation. Amin S. Herati; Mohamed A. Atalla; Soroush Rais-Bahrami; Sero Andonian; Manish A. Vira; Louis R. Kavoussi // Journal of Endourology;Sep2009, Vol. 23 Issue 9, p1535 

    AbstractIntroduction:Laparoscopic trocars typically maintain pneumoperitoneum using trap door valves and silicone seals. However, valves and seals hinder passage of instruments, cause lens smudging, trap specimens and needles being removed from the abdominal cavity, and lose their seal with...

  • Evaluation of Laparoendoscpic Single-site Gynecologic Surgery with a Multitrocar Access System. Ichikawa, Masao; Akira, Shigeo; Mine, Katuya; Ohuchi, Nozomi; Iwasaki, Nao; Kurose, Keisuke; Takeshita, Toshiyuki // Journal of Nippon Medical School;2011, Vol. 78 Issue 4, p235 

    Objects: Laparoendoscopic single-site surgery (LESS) is an ideal approach for gynecologic surgery and yields better cosmetic results. However, a standard umbilical approach with LESS is not appropriate for gynecologic surgery requiring intra-abdominal suturing and dissection requiring traction....

  • Comparison of changes in retentive force of three stud attachments for implant overdentures. Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh // Journal of Advanced Prosthodontics;Aug2015, Vol. 7 Issue 4, p303 

    The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS. Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant...

  • Safe and Rapid Laparoscopic Access--a New Approach. Antevil, Jared L.; Bhoyrul, Sunil; Brunson, Mathew E.; Vierra, Mark A.; Swadia, Nayan D. // World Journal of Surgery;Jun2005, Vol. 29 Issue 6, p800 

    Despite numerous recent technical advances in minimally invasive surgical technique, the potential exists for serious morbidity during initial laparoscopic access. Safe access depends on adhering to well-recognized principles of trocar insertion, knowledge of abdominal anatomy, and recognition...

  • Randomized Prospective Trial on the Occurrence of Laparoscopic Trocar Site Hernias. Lago, Jesús; Serralta, Daniel; García, Andrés; Martín, Jorge; Sanz, Mercedes; Pérez, Maria Dolores; Turégano, Fernando // Journal of Laparoendoscopic & Advanced Surgical Techniques;Nov2011, Vol. 21 Issue 9, p775 

    Introduction: Laparoscopy has become the gold standard in an increasing number of procedures. We analyze the incidence of trocar site hernias (TSH) and determine whether closure of the external fascia prevents onset of TSH and possible complications. Methods: We performed a simple-blind...