TITLE

Inter-instrument agreement and influence of central corneal thickness on measurements with Goldmann, pneumotonometer and noncontact tonometer in glaucomatous eyes

AUTHOR(S)
Gupta, Viney; Sony, Parul; Agarwal, Harish C.; Sihota, Ramanjit; Sharma, Ajay
PUB. DATE
December 2006
SOURCE
Indian Journal of Ophthalmology;Dec2006, Vol. 54 Issue 4, p261
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: This study was conducted to compare the intraocular pressure (IOP) measurements by the Goldman applanation tonometer (GAT), non contact tonometer (NCT) and the ocular blood flow (OBF) pneumotonometer in different IOP ranges in glaucomatous eyes. The effect of central corneal thickness (CCT) on IOP measurement in chronic glaucomatous eyes using the three different tonometers was also evaluated. Materials and Methods: IOP measurements of 130 eyes of primary glaucoma patients were performed using GAT by an ophthalmologist while NCT and OBF-pneumotonometer measurements were performed by an experienced optometrist. The IOP values were compared amongst the three instruments in the three different IOP ranges (0-18 mmHg, > 18 to 25 mmHg, > 25 mmHg). CCT was also measured in all patients. Results: The mean of paired difference between GAT and NCT was 0.9 ± 3.1 mmHg while that between GAT and OBF-pneumotonometer was 0.3 ± 3.4 mmHg. The OBF-pneumotonometer and NCT were more affected by corneal thickness (0.41 mmHg and 0.4 mmHg / 10 µ corneal thickness respectively) while GAT was the least affected by corneal thickness (0.3 mmHg / 10 µ corneal thickness) though the difference was not statistically significant (P=0.42). Conclusion: With appropriate correction for corneal thickness the NCT and OBF-pneumotonometer can be used as reliably as GAT in following up glaucomatous patients.
ACCESSION #
23130805

 

Related Articles

  • The influence of new beta-adrenolytics nebivolol and carvedilol on intraocular pressure and iris blood flow in rabbits. Szumny, Dorota; Szeląg, Adam // Graefe's Archive of Clinical & Experimental Ophthalmology;Jun2014, Vol. 252 Issue 6, p917 

    Background: The aim of this study was to assess the influence of propranolol, nebivolol, and carvedilol on intraocular pressure and blood flow in vessels of rabbit's (New Zealand White) eyeball. Methods: The study was carried out on New Zealand white rabbits. Intraocular pressure was measured...

  • Corneal biomechanical factors may skew IOP measurement in diabetic patients. Hasson, Matt // Ocular Surgery News Asia-Pacific;Feb2010, Vol. 21 Issue 2, p9 

    The article discusses the possible effects of corneal biomechanical changes in the intraocular pressure (IOP) measurement in diabetic patients. According to Doctor Atilla Bayer, clinicians should consider the possible effects during glaucoma management. It also cites the relationships between...

  • Effect of Central Corneal Thickness and Radius of the Corneal Curvature on Intraocular Pressure Measured With the Tono-Pen and Noncontact Tonometer in Healthy Schoolchildren. Yildirim, Nilgun; Sahin, Afsun; Basmak, Hikmet; Bal, Cengiz // Journal of Pediatric Ophthalmology & Strabismus;Jul/Aug2007, Vol. 44 Issue 4, p216 

    Purpose: To determine the effect of central corneal thickness and radius of the corneal curvature on intraocular pressure (IOP) measurements using the Tono-Pen and a noncontact tonometer in healthy Turkish schoolchildren. Subjects and Methods: IOP was measured with the Tono-Pen and a noncontact...

  • Diaton Transpalpebral Tonometrenin Goldmann Aplanasyon Tonometre ve Canon TX-F Non-Kontakt Tonometresi ile KarşılaÅŸtırılması. Toker, Mustafa İlker; Vural, Ayşe; Erdoğan, Haydar; Topalkara, Ayşen; Arici, Mustafa Kemal // Glokom-Katarakt/Journal of Glaucoma-Cataract;Jun2007, Vol. 2 Issue 2, p115 

    Purpose: To compare the intraocular pressure values of Diaton transpalpebral tonometer (DTT) with those of the Goldmann applanation tonometer (GAT) and Canon TX-F noncontact tonometer. Materials and Methods: 103 eyes of 52 normal individuals not applied any intraocular or upper eyelid surgery...

  • Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Gunvant, P.; Baskaran, M.; Vijaya, I.; Joseph, I. S.; Watkins, R. J.; Nallapothula, M.; Broadway, D. C.; O'Leary, D. J. // British Journal of Ophthalmology;Apr2004, Vol. 88 Issue 4, p518 

    Aims: To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood How tonograph and the...

  • Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children. Raina, Usha Kaul; Rathie, Neha; Gupta, Anika; Gupta, Shantanu Kumar; Thakar, Meenakshi // Oman Journal of Ophthalmology;Feb2016, Vol. 9 Issue 1, p22 

    Background: To evaluate the agreement of Goldmann applanation tonometer (GAT) with Tono-Pen and noncontact tonometer (NCT) for measurement of intraocular pressure (IOP) in pediatric age group and to evaluate the correlation between central corneal thickness (CCT) and IOP measured with the...

  • Rectifying calibration error of Goldmann applanation tonometer is easy! Choudhari, Nikhil S.; P., Krishna Moorthy; Tungikar, Vinod B.; Kumar, Mohan; George, Ronnie; Rao, Harsha L.; Senthil, Sirisha; Vijaya, Lingam; Garudadri, Chandra Sekhar // Indian Journal of Ophthalmology;Nov2014, Vol. 62 Issue 11, p1082 

    Purpose: Goldmann applanation tonometer (GAT) is the current Gold standard tonometer. However, its calibration error is common and can go unnoticed in clinics. Its company repair has limitations. The purpose of this report is to describe a self-taught technique of rectifying calibration error of...

  • Latanoprost-Induced Changes in Rat Intraocular Pressure: Direct or Indirect? Husain, Shahid; Yates, Phillip W.; Crosson, Craig E. // Journal of Ocular Pharmacology & Therapeutics;Aug2008, Vol. 24 Issue 4, p367 

    Introduction: The topical application of prostaglandin F2 α (FP)-receptor agonists has been shown to significantly lower intraocular pressure (IOP) in humans and is now considered the first-line treatment for ocular hypertension. Despite the prominent role FP-receptor agonists play in the...

  • Normal ve Glokomlu Olgularda Göz İçi Basınç DeÄŸiÅŸiminin Oküler Nabız Basıncı Ãœzerindeki Etkisi. Cömert, Ebru; Beden, Ümit; Özarslan, Mehtap; Sönmez, Barış; Öge, İhsan; Erkan, Dilek // Glokom-Katarakt/Journal of Glaucoma-Cataract;Dec2011, Vol. 6 Issue 4, p230 

    Purpose: To assess the affect of intraocular pressure (IOP) change on ocular pulse amplitude (OPA) in normal and glaucomatous eyes. Materials and Methods: IOP and OPA of 55 eyes with open angle glaucoma and 51 control eyes were recorded both before and after topical application of apraclonidin...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics