Background: Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatment of dorsally comminuted extra-articular distal radial fractures, under loading conditions simulating the physiologic forces that are experienced during early active rehabilitation. Methods: With use of a previously validated Sawbones fracture model, a dorsally comminuted extra-articular distal radial fracture was created. The fracture fixation stability of four volar plates (an AO T-plate, an AO 3.5-mm small-fragment plate, an AO 3.5-mm small-fragment locking plate, and the Hand Innovations DVR locking plate) were compared under axial compression loading and dorsal and volar bending simulating the in vivo stresses that are generated at the fracture site during early unopposed active motion of the wrist and digits. A single dorsal plate (an AO pi plate) was used for comparison, with and without simulated volar cortical comminution. The construct stiffness was measured to assess the resistance to fracture gap motion, and comparisons were made among the implants. Results: The volar AO locking and DVR plates had greater resistance to fracture gap motion (greater stiffness) compared with the volar AO nonlocking and AO T-plates under axial and dorsal loading conditions (p < 0.01), with no significant difference between the AO volar locking and DVR plates. The volar AO locking plate had greater resistance to fracture gap motion than did the volar AO nonlocking plate under axial loading and dorsal bending forces (p < 0.01). The dorsal pi plate had the greatest resistance to fracture gap motion under axial loading and volar and dorsal bending forces (p < 0.01). However, the pi plate was significantly less stable to axial load and dorsal bending forces when the volar cortex was comminuted (p < 0.01). Conclusions: In this model of dorsally comminuted extra-articular distal radial fractures, dorsal pi-plate fixation demonstrated better resistance to fracture gap motion than did the four types of volar plate fixation. The AO volar locking and DVR plates conferred the greatest resistance to fracture gap motion among the four volar plates tested. Volar locking technology conferred a significant increase in resistance to fracture gap motion as compared with nonlocking plate technology. Clinical Relevance: The present study provides comparative biomechanical data that may be helpful for individualizing plate fixation techniques and postoperative rehabilitation protocols for the treatment of dorsally comminuted extra-articular distal radial fractures. While the dorsal pi plate had the highest resistance to fracture gap motion, the locked volar plates showed significantly higher resistance to fracture gap motion than the unlocked plates did, suggesting that either surgical approach (dorsal or volar) combined with rigid plate fixation should allow for early assisted finger and wrist motion in the treatment of comminuted distal radial (Colles-type) fractures.
ACCESSION #
23113239

 

Related Articles

  • Prospective Descriptive Study of Short-term Result of Ipsi-lateral Fracture Neck Shaft Femur Treated by Modified Traditional Antegrade Interlocking Nailing and Lag Screw. Alshemmari, Zaid A. A.; Joda, Ahmed I. // Iraqi Journal of Medical Sciences;2015, Vol. 13 Issue 1, p64 

    Background Ipsilateral concomitant fractures of the femoral neck and femoral shaft are unusual (incidence 5-6%), and pose a difficult treatment problem. This injury usually resulting from high energy trauma, road traffic accident and fall from height. Many treatment methods have been invented...

  • MAXILLOFACIAL TRAUMA: Rigid versus Nonrigid Fixation. Ellis III, Edward // Peterson's Principles of Oral & Maxillofacial Surgery;2004, Vol. 1, p371 

    Chapter 20 of the book "Peterson's Principles of Oral and Maxillofacial Surgery" is presented. It defines rigid internal fixation as a form of bone fixation to avoid interfragmentary motion across the fracture. It explains the types of nonrigid fixation that allow the use of skeleton during the...

  • A new device for the internal fixation of wrist fractures: preliminary communication. Myles, John W. // Journal of the Royal Society of Medicine;Mar1978, Vol. 71 Issue 3, p186 

    The article presents a case report on a 17 year old girl who uses the wrist fixation device that is designed to control Colles' fracture by internal splintage. Techniques and control of the Colles' fracture is described to difficult and complicated. Other device including bone grafting prevents...

  • Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage. Martetschläger, Frank; Kraus, Tobias; Schiele, Clara; Sandmann, Gunther; Siebenlist, Sebastian; Braun, Karl; Stöckle, Ulrich; Freude, Thomas; Neumaier, Markus // Knee Surgery, Sports Traumatology, Arthroscopy;May2013, Vol. 21 Issue 5, p1189 

    Purpose: The purpose of the current study was to assess the clinical and radiological results after locking T-plate osteosynthesis with coracoclavicular augmentation of unstable and displaced distal clavicle fractures (Neer type 2). Methods: Thirty patients, treated between January 2007 and...

  • Surgical Treatment of Three and Four-Part Proximal Humeral Fractures. Solberg, Brian D.; Moon, Charles N.; Franco, Dennis P.; Paiement, Guy D. // Journal of Bone & Joint Surgery, American Volume;Jul2009, Vol. 91-A Issue 7, p1689 

    Background: Optimal surgical management of three and four-part proximal humeral fractures in osteoporotic patients is controversial, with many advocating prosthetic replacement of the humeral head. Fixed-angle locked plates that maintain angular stability under load have been proposed as an...

  • Comparison of Surgical Outcomes of Intra-Articular Calcaneal Fractures by Age. Gaskill, Trevor; Schweitzer, Karl; Nunley, James // Journal of Bone & Joint Surgery, American Volume;12/15/2010, Vol. 92-A Issue 18, p2884 

    Background: Internal fixation is an accepted treatment for displaced fractures of the calcaneus. Operative intervention in older patients, however, is traditionally discouraged in the literature. The purpose of this study was to compare the outcomes of internal fixation of intra-articular...

  • Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures. Chang-Wug Oh; Jung-Jae Kim; Young-Soo Byun; Jong-Keon Oh; Joon-Woo Kim; Shin-Yoon Kim; Byung-Chul Park; Hyun-Joo Lee // Archives of Orthopaedic & Trauma Surgery;Dec2009, Vol. 129 Issue 12, p1659 

    Intramedullary nailing is a mainstay in the treatment of subtrochanteric femoral fractures. But nailing is often unsuitable for difficult fracture patterns with comminution or when the medullary canal is narrow. The purpose of this study was to clarify the efficacy of minimally invasive plate...

  • Early ORIF of Tibial Pilon Fractures is Safe. Kuznar, Wayne // MD Conference Express;Dec2014, Vol. 14 Issue 41, p6 

    The complication rate with acute fixation of pilon fractures is comparable to that of delayed or staged fixation. This article discusses early and medium-term data from a prospective cohort study examining early open reduction and internal fixation of tibial pilon fractures.

  • DLS 5.0 - The Biomechanical Effects of Dynamic Locking Screws. Döbele, Stefan; Gardner, Michael; Schröter, Steffen; Höntzsch, Dankward; Stöckle, Ulrich; Freude, Thomas // PLoS ONE;Apr2014, Vol. 9 Issue 4, p1 

    Introduction: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics