TITLE

Divertor interferometer diagnostic for ITER

AUTHOR(S)
Brower, D. L.; Deng, B. H.; Ding, W. X.
PUB. DATE
October 2006
SOURCE
Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E911
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In the harsh environment of the divertor region in ITER, plasmas spanning a huge density range from 1019 to 1022 m-3 are anticipated making measurement of the electron density particularly challenging. For any reasonable wavelength choice, the total phase measured by a conventional two-color interferometer system is always >2Ï€ and therefore subject to fringe counting errors. This problem can be remedied by adding a polarimeter capability whereby the Cotton-Mouton effect is measured or by employing differential interferometry. Using either approach, the total phase is always <2Ï€. The conceptual design of an interferometer system along with possible wavelength choices will be explored.
ACCESSION #
23073261

 

Related Articles

  • A Martin–Puplett cartridge FIR interferometer. Smith, Roger J.; Penniman, Edwin E.; Jarboe, Thomas R. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3426 

    A compact prealigned Martin–Puplett interferometer (MPI) cartridge for plasma interferometry is described. The MPI cartridge groups all components of a MP interferometer, with the exception of the end mirror for the scene beam, on a stand-alone rigid platform. The interferometer system is...

  • Precision Phase Discriminator for the Heterodyne Interferometric Plasma-Density Measurement Technique. Zubarev, P. V.; Khil'chenko, A. D. // Instruments & Experimental Techniques;Mar/Apr2003, Vol. 46 Issue 2, p171 

    The discriminator is intended for the plasma density recording systems based on optical heterodyne interferometry. The discriminator has a high phase resolution (10–3 rad) and a virtually unlimited dynamic range in a modulation band of up to one-half of the carrier frequency (1 MHz)....

  • Two-dimensional phase contrast interferometer for fluctuations study on LHD. Sanin, A. L.; Tanaka, K.; Vyacheslavov, L. N.; Kawahata, K.; Akiyama, T. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3439 

    CO2 laser based phase contrast interferometer was used previously on LHD to study plasma density microfluctuations. New two-dimensional 6×8 elements array of CdHgTe photoconductors was employed for detection. In addition to commonly measured intensity, frequency spectrum, and two-point...

  • High resolution CO2 interferometry on the TJ-II stellarator by using an ADC-based phase meter. Sánchez, M.; Sánchez, J.; Estrada, T.; Sánchez, E.; Acedo, P.; Lamela, H. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3414 

    A 10 MSample/s analog-to-digital converter has been used to analyze the signals from the double wavelength heterodyne interferometer (CO2 10.6 μm, HeNe 0.63 μm) in the TJ-II stellarator. The phase difference between the two interferometers has been calculated using a new algorithm in...

  • Fiber optic two-color vibration compensated interferometer for plasma density measurements. Van Zeeland, M. A.; Boivin, R. L.; Carlstrom, T. N.; Deterly, T.; Finkenthal, D. K. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F325 

    A fiber optic, heterodyne, two-color interferometer utilizing wavelength division multiplexing technology has been developed for measuring electron density in plasmas. Vibration compensation is accomplished via common path 1.31 and 1.55 μm distributed feedback laser interferometers. All beam...

  • Measurements of Alfvén Eigenmodes in Fusion Plasmas. Van Zeeland, M. A.; Kramer, G. J. // AIP Conference Proceedings;3/12/2008, Vol. 988 Issue 1, p103 

    Ensuring appropriate measurements of Alfvén eigenmodes in burning plasma experiments will allow the validation of predictions of alpha driven instabilities in plasmas dominated by self heating from fusion produced alpha particles and provide the control capability for optimizing performance,...

  • Improved common-path fast-scanning heterodyne interferometer system as potential dense-plasma diagnostics. Nam, Y. U.; Cheon, M. S.; Ha, J. H.; Hwang, Y. S. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3417 

    An improved common-path fast-scanning heterodyne interferometer system has been developed. The mechanical vibration is one of the most critical error sources in typical interferometry system. These errors can be mostly eliminated in a common-path interferometry using a full common-mode rejection...

  • Optical diagnostics on dense Z-pinch plasmas. Riley, R. A.; Lovberg, R. H.; Shlachter, J. S.; Scudder, D. W. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5202 

    A novel "point-diffraction" interferometer has been implemented on the Los Alamos solid fiber Z-pinch experiment. The laser beam is split into two legs after passing through the plasma. The reference leg is filtered with a pin-hole aperture and recombined with the other leg to form an...

  • Madison symmetric torus far-infrared interferometer. Burns, S. R.; Peebles, W. A.; Holly, D.; Lovell, T. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4993 

    A far-infrared (FIR) interferometer plasma density diagnostic has been installed on the Madison Symmetric Toms (MST) at the University of Wisconsin at Madison. This collaborative experiment between University of California at Los Angeles and the University of Wisconsin at Madison has been...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics