TITLE

Twenty-channel bolometer array for studying impurity radiation and transport in the TCS field-reversed configuration

AUTHOR(S)
Kostora, M. R.; Hsu, S. C.; Wurden, G. A.
PUB. DATE
October 2006
SOURCE
Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E511
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A bolometer array diagnostic has been developed for the University of Washington Translation, Confinement, and Sustainment (TCS) field-reversed configuration (FRC) experiment in order to measure radially resolved total radiated power per unit length of the FRC. This will provide radiation energy loss information, useful in power balance and impurity studies. The 20-element photodiode bolometer will be mounted at the midplane of the TCS cylindrical vacuum chamber to view the rotating magnetic field (RMF) generated FRC plasma. Key features of this new bolometer array are (1) extensive electrical shielding against the RMF, (2) robust electrical isolation, (3) trans-impedance amplifiers using a microcoax interface at the array and a fiber optic interface to the screen room, and (4) a custom glass-on-metal socket for the 20-element photodiode chip to ensure high vacuum compatibility. The bolometer array can be retracted behind a gate valve using a stepper motor to protect it during vacuum chamber bakeout. The slit assembly housing is interchangeable to provide flexibility for the viewing sightlines.
ACCESSION #
23073229

 

Related Articles

  • A radiation foil bolometer for measuring the energy losses of fast Z-pinches. Volkov, G. S.; Lakhtyushko, N. I.; Terent'ev, O. V. // Instruments & Experimental Techniques;Sep2010, Vol. 53 Issue 5, p728 

    radiation foil bolometer intended for measuring radiation-energy fluxes and plasma flows in high-power pulsed plasma X-ray sources is studied. In the bolometer, the radiation or ion-flow energy is absorbed by a 13-μm-thick niobium foil preliminarily heated to T ≈ 1900 K by a...

  • Soft X-ray Emission from the Plasma of a Conductor Exploding in a Strong Longitudinal Magnetic Field. Adamian, Yu. É.; Shneerson, G. A. // Technical Physics Letters;May2003, Vol. 29 Issue 5, p395 

    Previous experiments with the electric explosion of conductors in a strong (50 T) longitudinal magnetic field showed the formation of a relatively low-density plasma around the central part of the explosion channel, which exhibited expansion at a velocity on the order of 10-20 km/s [1, 2]....

  • A bolometer with thermal feedback: Testing of a prototype on the T-11M facility. Alekseev, A. G.; Panov, A. I. // Instruments & Experimental Techniques;Mar2010, Vol. 53 Issue 2, p307 

    A prototype of a bolometer with a deep thermal feedback (TF) is described. It allows stabilization of the temperature of an absorbing film at a level of 700�800�C by the control of its thermal radiation. The prototype was tested on a light-ion accelerator and a T-11M tokamak. The...

  • Carbon nanotube IR light detector is more sensitive. Yeates, Harry // Electronics Weekly;4/26/2006, Issue 2238, p30 

    The article reports that researchers in the U.S. have used carbon nanotubes to build an infra red (IR) light detector called IR bolometer. It is made by suspending a 0.5mm wide film of single-walled carbon nanotubes (SWNTs) over a 3.5mm gap between two electrical contacts. The film is heated by...

  • A novel THz source based on a two-color Nd:LSB microchip-laser and a LT-GaAsSb photomixer. Willer, U.; Wilk, R.; Schippers, W.; Böttger, S.; Nodop, D.; Schossig, T.; Schade, W.; Mikulics, M.; Koch, M.; Walther, M.; Niemann, H.; Güttler, B. // Applied Physics B: Lasers & Optics;Mar2007, Vol. 87 Issue 1, p13 

    A two-color Nd:LSB microchip-laser that simultaneously emits at 1061.3 nm and 1063.9 nm is used for photomixing. Since LT-GaAs which is typically utilized for photomixing cannot be excited efficiently with wavelengths exceeding 1 μm, LT-GaAsSb with a bandgap energy designed to match the laser...

  • Superconducting noise bolometer for terahertz radiation. Semenov, A. D.; Richter, H.; Hübers, H.-W.; Il'in, K. S.; Siegel, M. // Applied Physics Letters;10/24/2005, Vol. 87 Issue 17, p173508 

    We present a superconducting noise bolometer that is a bolometric detector sensing radiation via radiation-induced changes of its own microwave noise. The detector represents a nanostrip made from a thin NbN superconducting film. It operates in the superconducting state and carries a...

  • Measurement of the distribution of intensity in a beam of thermal radiation. Kokodii, N.; Kokodii, D. // High Temperature;Mar2007, Vol. 45 Issue 2, p255 

    An experiment is described which involves measurements of the distribution of intensity in a beam of optical radiation using a grid of metal wires (bolometers). The resistance of each bolometer is determined, which depends on the intensity of radiation at the location of the bolometer. The...

  • Terahertz hot electron bolometer waveguide mixers for GREAT. Pütz, P.; Honingh, C. E.; Jacobs, K.; Justen, M.; Schultz, M.; Stutzki, J. // Astronomy & Astrophysics / Astronomie et Astrophysique;Jun2012, Vol. 542 Issue 1, p1 

    Context. Supplementing the publications based on the first-light observations with the German REceiver for Astronomy at Terahertz frequencies (GREAT) on SOFIA, we present background information on the underlying heterodyne detector technology. This Letter complements the GREAT instrument Letter...

  • Bolometric THz-to-IR converter for terahertz imaging. Kuznetsov, Sergey A.; Paulish, Andrey G.; Gelfand, Alexander V.; Lazorskiy, Pavel A.; Fedorinin, Victor N. // Applied Physics Letters;7/11/2011, Vol. 99 Issue 2, p023501 

    The quasi-optical bolometric converter of terahertz (THz) waves into infrared (IR) radiation is proposed and experimentally investigated. The converter includes an ultra-thin THz absorber (with a thickness 1/50 of the operating free-space wavelength) based on an artificial impedance surface with...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics