TITLE

Multilayer mirror monochromatic self-emission x-ray imaging on the Z accelerator

AUTHOR(S)
Jones, B.; Deeney, C.; Coverdale, C. A.; Meyer, C. J.; LePell, P. D.
PUB. DATE
October 2006
SOURCE
Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E316
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A time-resolved, monochromatic soft x-ray diagnostic has been developed for self-emission imaging of imploding z pinches on the Z accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)] at Sandia National Laboratories. Multiple pinhole images are reflected from a planar multilayer mirror with narrow photon energy bandwidth (<10 eV) onto a 1 ns gated microchannel plate detector. High-energy bremsstrahlung x rays are not reflected, providing improved signal to noise in comparison to a standard filtered pinhole camera included in the same beamline of the instrument. An example of data from the existing ∼277 eV imaging system is presented, showing cooler imploding mass extending to larger radius than the on-axis K-shell emission of an aluminum wire array. Multilayer mirror and filter pair configurations ranging from 96 to 769 eV are discussed.
ACCESSION #
23073219

 

Related Articles

  • Spectral softening through Compton scattering. Pereira, N. R. // Journal of Applied Physics;3/1/1985, Vol. 57 Issue 5, p1445 

    Features a study that obtained flash bremsstrahlung from multi-megaelectronvolt electron beams by Compton backscatter from a material with low photoelectric absorption. Use of an x-ray transport code; Conversion efficiency between electric-beam energy and x-ray fluence from the converter with...

  • High energy photon radiation from a Z-pinch plasma. Velikovich, A. L.; Davis, J.; Oreshkin, V. I.; Apruzese, J. P.; Clark, R. W.; Thornhill, J. W.; Rudakov, L. I. // Physics of Plasmas;Oct2001, Vol. 8 Issue 10 

    A new approach to the generation of kilovolt x ray radiation in Z-pinch plasma radiation sources is proposed. In cases where the pulse power machine has insufficient energy to efficiently produce K-shell emission from the atomic number element that emits in the required kilovolt energy range, it...

  • Evaluating Zn[sub 2] SiO[sub 4] :Mn phosphor for use in medical imaging radiation detectors. Kandarakis, I.; Cavouras, D.; Prassopoulos, P.; Kanellopoulos, E.; Nomicos, C.D.; Panayiotakis, G.S. // Applied Physics A: Materials Science & Processing;1998, Vol. 67 Issue 5, p521 

    Abstract. Zn[sub 2]SiO[sub 4]:Mn phosphor was evaluated for use in radiation detectors of medical imaging systems. Zn[sub 2]SiO[sub 4]:Mn was used in the form of laboratory-prepared fluorescent layers (screens) with coating weights from 18 to 150 mg/cm[sup 2]. The phosphor was excited to...

  • Combined Imaging System for X-ray Fluorescence and Transmission X-ray Microtomography. Ohigashi, Takuji; Watanabe, Norio; Yokosuka, Hiroki; Aoki, Sadao; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1352 

    A full-field imaging x-ray fluorescence computed microtomography system was designed for quantitative elemental analysis. An x-ray fluorescence imaging microscope combined with transmission x-ray microtomographic system was constructed at BL3C2 of the Photon Factory, KEK, Japan. The...

  • ZnTe:O phosphor development for x-ray imaging applications. Kang, Z. T.; Summers, C. J.; Menkara, H.; Wagner, B. K.; Durst, R.; Diawara, Y.; Mednikova, G.; Thorson, T. // Applied Physics Letters;3/13/2006, Vol. 88 Issue 11, p111904 

    An efficient ZnTe:O x-ray powder phosphor was prepared by a dry synthesis process using gaseous doping and etching medias. The x-ray luminescent properties were evaluated and compared to standard commercial phosphors exhibited an x-ray luminescent efficiency equivalent to 76% of Gd2O2S:Tb and an...

  • Energy-dispersive coherent scatter computed tomography. Delfs, J.; Schlomka, J.-P. // Applied Physics Letters;6/12/2006, Vol. 88 Issue 24, p243506 

    We present a reconstructive x-ray imaging technique that yields the spatially resolved coherent scatter form factor of macroscopic objects. High spectral resolution is obtained by the energy and angle analyses of coherently scattered photons. In comparison with transmission x-ray computed...

  • Design and Performance of the Compact YAG Imaging System for Diagnostics at GMCA Beamlines at APS. Shenglan Xu; Fischetti, Robert F.; Benn, Richard; Corcoran, Stephen // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p1403 

    A compact YAG (Chromium Doped Yttrium Aluminum Garnet — Cr4+:YAG) imaging system has been designed as a diagnostic tool for monochromatic x-rays emanating from the first “Hard” x-ray dual-canted undulator at the Advanced Photon Source at Argonne National Laboratory. This...

  • Environment for Single Photon Counting X-Ray Imaging System Design. Sang Don Kim; Seung Eun Lee // International Review of Physics;Dec2018, Vol. 12 Issue 2, p39 

    In this paper, we introduce an environment for multi-energy X-ray imaging system design. The environment has an emulator for pixel sensor, followed by data-acquisition and pre-processing unit. The proposed environment provides the way to verify the functionality of the image reconstruction...

  • Lensless X-ray imaging in reflection geometry. Roy, S.; Parks, D.; Seu, K. A.; Su, R.; Turner, J. J.; Chao, W.; Anderson, E. H.; Cabrini, S.; Kevan, S. D. // Nature Photonics;Apr2011, Vol. 5 Issue 4, p243 

    Lensless X-ray imaging techniques such as coherent diffraction imaging and ptychography, and Fourier transform holography can provide time-resolved, diffraction-limited images. Nearly all examples of these techniques have focused on transmission geometry, restricting the samples and reciprocal...