TITLE

Impact of a remote pump head on neonatal priming volumes

AUTHOR(S)
Horisberger, J.; Jegger, D.; Boone, Y.; Seigneul, I.; Pierrel, N.; Hurni, M.; Corno, A.; von Segesser, L.
PUB. DATE
September 1999
SOURCE
Perfusion;1999, Vol. 14 Issue 5, p351
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reduction of priming volumes of the cardiopulmonary bypass (CPB) circuit in neonatal cardiac surgery to decrease haemodilution and blood transfusion requirements can be achieved with the use of neonatal low prime oxygenators and smaller diameter tubing. We have further reduced our prime volume with the use of a custom-designed arm allowing for remote positioning of a double-headed roller pump. This arm enables the double pump to be placed alongside the main heart-lung machine close to the operating table, and to position the pump inlet and outlet tubing immediately at the reservoir outlet and oxygenator inlet, respectively, therefore reducing tubing lengths. Priming volumes of four cases using this configuration were compared to four cases using our standard neonatal bypass setup. Results showed a 29% decrease in priming volume and a 58% reduction in blood utilization during CPB. This reduction in priming volume is clinically significant as it lowers the ratio of priming volume to patient blood volume and reduces homologous blood requirements.
ACCESSION #
2301689

 

Related Articles

  • Air trapping ability of the Spiral Goldâ„¢ membrane oxygenator: an ex vivo study. Mueller, Xavier M; Tevaearai, Hendrick T; van Ness, Karen; Horisberger, Judith; Augstburger, Monique; Burki, Marco; von Segesser, Ludwig K // Perfusion;1998, Vol. 13 Issue 1 

    Despite an overall improvement in cardiopulmonary bypass (CPB) technology and materials, air emboli still occur. The latest generation membrane oxygenator from Bentley Laboratories, the SpiralGoldâ„¢, was tested ex vivo for its air handling ability. The study was conducted on four calves....

  • MAST system: a new condensed cardiopulmonary bypass circuit for adult cardiac surgery. McCusker, K.; Vijay, V.; DeBois, W.; Helm, R.; Sisto, D. // Perfusion;Nov2001, Vol. 16 Issue 6, p447 

    There have been many refinements in cardiopulmonary bypass (CPB) techniques over the past few decades specific to design, materials and function. Despite these improvements, use of the standard length circuit tubing and pump oxygenator alter cellular, biochemical and rheological properties by...

  • A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter. Ginther, Rm; Gorney, R; Cruz, R // Perfusion;May2013, Vol. 28 Issue 3, p194 

    High-performance, low-prime-volume oxygenators for the pediatric patient population have become a growing market among manufacturers. In the summer of 2011, our institution clinically evaluated the performance of the newly released Maquet Quadrox-i Neonatal oxygenator with integrated arterial...

  • Medtronic gets CE mark for Affinity Fusion system.  // Medical Device Daily;9/25/2012, Vol. 16 Issue 186, p1 

    The article reports on the CE mark received by Medtronic for its Affinity Fusion oxygenation system in Europe. Design enhancements to the oxygenation system are aimed at preventing and removing air bubbles that can enter the blood during open-heart surgical procedures. Included is a list of the...

  • The relative safety of an oxygenator. Svenmarker, S.; Haggmark, S.; Jansson, E.; Lindholm, R.; Appelblad, M.; Aberg, T. // Perfusion;1997, Vol. 12 Issue 5, p289 

    Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions. A general safety index (SI) was defined as the number of recorded...

  • Editorial. Taylor, K. // Perfusion;1998, Vol. 13 Issue 3, p155 

    Editorial. Discusses on the ability of membrane oxygenators to handle and remove air. Quantification and localization of the air removal characteristics of membrane oxygenators; Analysis on the design and manufacture of cardiopulmonary bypass circuit components for neonatal and pediatric...

  • The incidence and cause of emergency oxygenator changeovers. Fisher, A.R. // Perfusion;1999, Vol. 14 Issue 3, p207 

    Emergency oxygenator changeover presents as an important potential hazard during cardiopulmonary bypass. In order to assess the frequency and possible causes of this event a retrospective survey was conducted of cardiothoracic units in the UK and Ireland. The survey was sent to these units in...

  • Cryofibrination: did it really happen? Luckraz, H.; Boolauky, D.; Mohangee, A. // Perfusion;Jan2001, Vol. 16 Issue 1, p83 

    Cryofibrin precipitation is a phenomenon which has only recently been described, although it might have been present since the advent of membraneoxygenators for cardiopulmonary bypass procedures. The deposition of the cold-reactive protein, cryofibrin, causes progressive occlusion of the...

  • Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure. Groom, R. C.; Forest, R. J.; Cormack, J. E.; Niimi, K. S.; Morton, J. // Perfusion;Nov2002, Vol. 17 Issue 6, p447 

    We present here a technique to replace a failed oxygenator by inserting a second oxygenator in parallel (PRONTO) within the cardiopulmonary bypass (CPB) circuit. Oxygenator failure is a potential hazard that may result in patient injury or death. Although failures are rare, safety surveys...